Ledpax Technology LP4ICLED-6 Installation guide

Type
Installation guide
4"REMODEL HOUSING
LINE VOLTAGE HALOGEN
TO INSTALL REMODEL HOUSING
TOOLS REQUIRED
Keyhole saw wire strippers,tape measure.
CAUTION
Turn off power at main fuse panel be-fore installing any electrical fixture.The installation of
this fixture must comply with local codes.
IMPROPER
INSTALLATION
MAY RESULT
IN FIRE
PLATE
SNAP CLIP
JUNCTION BOX
SPRING CLIP
HOUSING
KNOCK-OUT
4.375 /111mm
HOLE CUTTING TEMPLATE
INSTALLATION
1. Carefully measure distance from walls and mark position of fixture to be
installed on ceiling.
2. Using template provided carefully scribe circle in desired location.
3. Carefully cut hole in ceiling with keyhole saw.
4. Remove knock-out from junction box.
5. Remove junction box cover.
6. Insert power cable from house through knock-out in junction
box.Fasten power cable in junction box with proper box connector.
7. Connect black wire of fixture to black wire of cable.Connect white
wire of fixture to white wire of power cable.Connect green
ground wire of fixture to green ground wire of power cable.Cover
these connections with wire nuts.Make certain there are no exposed
strands of wire.
8. Push wires into junction box and snap plate back into place.
9. Insert housing into ceiling junction box first.NOTE:Make sure the
spring clips are flush to outside of housing.
10.Hold housing flush against ceiling.Push end of spring clip out and away.
from housing.Push spring clip up until ceiling is clamped firmly between
housing and clip.Repeat with other clips.
11. install Recessed Trim according to trim installation instructions.
01