Hager TRM600AU Quick start guide

Type
Quick start guide
Radio control for latching relay,
timer
cfg
fct
L/N
TRM600
ε 0,5A AC1 230 V 50Hz
433.5 Mhz 10mW
3,5
max
cfg
fct
L/N
TRM600AU
ε 0,5A AC1 230 V
50Hz
433.5 Mhz 10mW
TRM600AU
0,5A AC1 230 V
50Hz
433.5 Mhz 10mW
L/N
z
Technical characteristics
Supply voltage
230 V
+10 %-15% 50 Hz
240 V +6%/-6% 50 Hz
Product consumption 100mW (max. 150mW)
Transmission frequency/
Emission power
433,05 - 434,79 MHz
10 mW
Dimensions 40 x 40 x 18 mm
Max. switch current
0.5A
Contact closure
duration
200ms
Degree of protection IP 20
Operating altitude
≤ 2000 m
Pollution degree 2
Overvoltage category III
Operating temperature -15 °C —> + 45 °C
Storage temperature - 25°C —> + 70 °C
Receiver category 2 / Transmitter duty cycle
<10%
Electric connection: 0,5 mm
2
—> 1,5 mm
2
0,5 mm
2
—> 2,5 mm
2
6LE005074D
- The device is to be installed only by a
qualified electrician in accordance with
the installation standards in force in the
country.
- Cut o the 230V power supply before
connecting the device.
The TRM600AU allows to add a radio control to an
existing latching relay or timer circuit powered by
230V. It is a radio receiver which only delivers a
calibrated pulse. It is dedicated to this application
and is placed in a flush mounted box, behind one of
the push buttons of the circuit to control. It connects
in parallel to the push button and consumes equal
to that required by a neon indicator of a push
button.
The TRM600AU is itself controlled through radio
transmitters. On each command received, its
output contact closes for 200 ms to control the
latching relay or timer in question.
Legend
1 Push button and function LED T of the output
2 Push button and configuration LED R
3 Terminal block
Functions
Single function receiver (pulse) controlled by radio
1 pulse output to control a latching relay or timer
In operation :
Option of manual control of the output: each
press of the T
push button = 1 control pulse.
Display of the output status on the fct LED: 1
single red flash corresponds to 1 pulse of 200 ms.
Quicklink configuration
Quicklink is the name of the tool free Hager
configuration mode for radio products. It uses the
function (fct) and configuration (cfg) buttons and
its Leds, located directly on the products. Only
the “pulse” function (select the timer symbol) and
erasing of the link are available on this product.
Limitations
Only latching relays or timers controlled at 230V
are compatible. In case of use with illuminated
push buttons, the current consumed by the product
must be considered as < than 1mA.
Factory Reset
Press and hold the R push button until the cfg
LED starts flashing (>10s). The factory reset is
complete when the cfg LED light goes out.
This operation leads to complete erasing of the
product configuration, regardless of the configuration
mode. After switching on or a factory reset, wait for
15 sec. before proceeding with configuration.
O
This manual is an integral part of the product
and must be kept by the end user.
6LE005074D1
TRM600AU
Complies with
IMDA Standards
DA101847
Metal surfaces in the direct vicinity of the
product (e.g. flush mounted metal boxes)
may reduce the radio range.
Avoid the use of a metal front plate for
switches in combination with flush mounted
metal boxes.
Hager Controls hereby declares that the radio
transmitter/receiver complies with the 2014/53/
EU directive.
The CE declaration can be consulted
on the site:
www.hager.com
å
and
In1
In2
cfg
TRM702AU
IP30
Confi guring a pulse function (5 steps)
Example : Link between a conventional push button connected to the radio transmitter TRM702AU and the TRM600AU receiver for pulse function.
Action
Result
Starting confi guration
Give a short press on the J button of
the transmitter or transmitter/receiver.
The
cfg
LEDs of all the
receivers and the emitter
come on.
Input selection
Give a short press on the button to be
configured.
The
cfg
LED of the emitter
flashes for 1 s.
Function selection
Select the function by successive short
presses on the K button of the receiver
to be controlled.
Scrolling of the functions
indicated by the colour of the
fct LED :
- first press = pulse function
- second press = delete link
Confi rmation of the function
Press for > 2s on button K of the
receiver until the cfg
LED flashes.
The function identified by
the colour of the
fct LED
is confirmed.
Exiting confi guration mode
Give a short press on the J
button of the transmitter or transmitter/
receiver.
The
cfg
LEDs of all the
receivers and the emitter
go out. End of configuration.
Display of a confi gured function
In step
2
the fct LED indicates the colour of the
confi gured function.
Group control
Repeat steps
3
and
4
on the other receivers to
be integrated in a group.Only the function selected
on the fi rst receiver and clearing will be available
for selection on the other receivers.
Editing a confi gured function
In step
3,
you can edit the displayed function,
except in the case of group control where it is
necessary to clear the receivers of the group
before choosing a new function.
Clearing a confi gured function
In step
3
select the "Clear" function and then
confi rm in step
4
.
Error signals
A very rapidly fl ashing cfg LED indicates an error
or an incompatible link. (e.g. a group control mixing
lighting and shutter commands).
System limit
A product may be linked to a maximum to 20 other
products.
In1
In2
In1
In2
cfg
cfg
TRM702AU
IP30
TRM702AU
IP30
In1
In2
In1
In2
cfg
cfg
TRM702AU
IP30
TRM702AU
IP30
In1
In2
cfg
TRM702AU
IP30
TRM600AU
0,5A AC1 230 V 50Hz
433.5 Mhz 10mW
L/N
In1
In2
TRM702AU
IP30
cfg
TRM600AU
0,5A AC1 230 V 50Hz
433.5 Mhzz 10mW
1x
2x
3x
4x
L/N
fct
TRM600AU
0,5A AC1 230 V 50Hz
433.5 MhzW
> 2s
L/N
fct
TRM600AU
0,5A AC1 230 V 50Hz
433.5 Mhz 10mW
L/N
TRM600AU
0,5A AC1 230 V 50Hz
433.5 Mhz 10mW
L/N
In1
In2
cfg
TRM702AU
IP30
L
TRM
600AU
3 wires 4 wires TRM702AU
A1
A2
1
2
N
L
A1
A2
1
2
N
In1
In2
TRM702A
RF1.M EC/EP
868 MHz
IP30
cfg
TRM
600AU
2x 3x1x
= 200ms DeleteLed fct
TRM600AU
0,5A AC1 230 V 50Hz
433.5 Mhz 10mW
L/N
6LE005074D
2
Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com
  • Page 1 1
  • Page 2 2

Hager TRM600AU Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI