Specifications
Wire Verication Distance 10,000 feet (3000 meters)
Minimum Wire Size 26 gage
Power Supply 9V battery
Product Certications CE
Visual Indicator Yes (Green and Red LEDs)
Audible Indicator Yes (Pulsating Beeper, approx. 85 dB)
Fuse Protection 0.5A/250V
Continuity Conrmation Equal to or less than 2.0 K Ohms
Operating Temperature 14 to 113°F (-10 to 45°C)
Operating Humidity 0-85%
Storage Temperature 14 to 122°F (-10 to 50°C)
Dimensions 4.5 x 3 x 1.1 “ (115 x 75 x 29mm)
Weight 3.9oz (111g)
Operating Instructions
Remote Continuity Test
Remote continuity testing requires both the Main Unit and Remote Unit.
This test is mainly used for verication of continuity for cable/wires, or
identication of cable/wires. Ideally used for testing cable TV, electrical
cables, and telephone/speaker wiring in multi-room or multi-oor
installations. The remote continuity test mode can be used to check
continuity and identify two, three or more cables/wires by applying simple
logic and testing strategy.
1. Turn on the Main Unit and the Power LED light will turn green. If
LED light does not turn on, replace the battery.
2. Refer to Figure 2, attach the red and black clips of the Main Unit to
one end of cable/wires under test, then go to the other end of the
cable/wires and connect them to the test leads of the Remote Unit.
3. If continuity exists, the bi-color LED of the Remote Unit will ash
either green or red depending on the Remote Unit leads orientation.
Meanwhile the Main Unit will beep and the continuity LED will
ash red.
REED Instruments