Carson MM-480 is a digital microscope that offers an effective magnification of up to 65x on a 21-inch computer monitor. It connects to your computer via USB and is compatible with both Mac and PC. You can capture images and videos, and even use the timed shot feature to automatically capture images at regular intervals. The microscope also comes with two adapters for viewing different areas of the face and scalp.

Carson MM-480 is a digital microscope that offers an effective magnification of up to 65x on a 21-inch computer monitor. It connects to your computer via USB and is compatible with both Mac and PC. You can capture images and videos, and even use the timed shot feature to automatically capture images at regular intervals. The microscope also comes with two adapters for viewing different areas of the face and scalp.

CARSON
MM-480
zOrb
User Guide
TM
Digital Microscope
PDF : www.carson.com/MM480guide
English / Français / Español / Deutsch /
日本語
I
Table of Contents
Important information................................................. 3
Product description.................................................... 3
Computer requirements & Software installation...................... 3
Package contents...................................................... 4
Product overview....................................................... 5
Product specification................................................. 6
Operation................................................................................ 7
Connecting the device............................................................ 7
Focusing.............................................................. 8
Using the xploview software.............................................. 9
System settings menu...........................................10
Device setup....................................................11
Timed shot setup.............................................. 11
Movie setup..................................................... 11
Save setting.....................................................11
Language setting..............................................11
Advanced settings............................................ 12
Saved files........................................................... 12
Full screen........................................................... 13
Care and maintenance......................................................... 13
Warning................................................................... 14
Warranty description............................................................. 14
Warranty procedure.............................................................. 15
2
I
Important information
Please read this instruction manual carefully before using this
product, and retain this instruction for future reference.
Improvements and changes to this text necessitated by
typographical errors, or improvements to the software and/or
equipments may be made at any time without notice.
Product description
This product is a USB powered device which features an
effective magnification of 65x on a 21" computer monitor.
Capture an image to keep with the click of a button. You can
even capture close-focus video!
Compatible with Mac and PC.
This item can be used with applications that support the viewing
of USB video devices (these applications are not included).
USB 2.0 required. No batteries required.
Computer requirements &
Software Installation
Go to www.carson.com/software to download the latest
software and corresponding software installation guide
for the MM-480. The computer requirements (operating
system, etc.) may be different depending on the software
version.
3
I
Package contents
1. Digital Microscope
x1
2. Adapter for face/scalp
x1
3. Adapter for nose/ears
x1
4
I
Product overview
1. Shutter Button
2. Focusing Ring
3. Lens
4. LED Illumination
5. Adapter slot
6. USB Cable
5
Magnification on 4:3
Reference Displays
Image Sensor Format
Image Resolution
Digital Microscope
Net Weight
Approximate
Dimensions
I
65x@21"
85x@27"
2.0 MPixel
UXGA
CMOS
1600 X 1200 Pixels
(UXGA)
5V
DC250mA
(USB 2.0)
104g
W50mm
x
D50mm
x
H74mm
Product specifications
Optical Specifications
Effective*
* Please note that the effective magnification is a combination of the
optical system and a high powered digital zoom.
Power Ratings
Physical Property
6
I
Operation
To view the images clearly, please use one of the adaptors
provided.
Choose an adaptor, place it into the adaptor slot located
under the main body. Lock by turning in clockwise direction.
Connecting the device
Connect the device to the computer using the USB cable
provided. The LED light will turn on indicating that the
device is powered on.
When the device is connected to the computer for the first time,
a driver will automatically be installed by Windows or Mac OS.
This process could take up to a few minutes.
7
I
Focusing
Rotate the focusing ring clockwise or
counterclockwise until the viewing image shown on
the monitor is clear and sharp.
To capture an image, press the shutter button on
top of the zOrb.
8
I
Using the xploview software
The following buttons are available:
Clicking this will open the system
settings menu (see next section).
Clicking this will capture the on
screen image of the device.
Clicking this will activate or deactivate
the timed shot feature. When activated,
images will be captured at a regular
interval.
Clicking this will activate or deactivate
the video recording feature.
Clicking this will show the copyright and
version information of the application
software.
Clicking this will shut down the
application software.
9
'-"'~!<:"
-,;.-..p
Lit,,'la!: [
USO
Carer
a
91:M,ll'lll.(l-X.OS'ots)
Minul2{1J(l·l00Cmn.
)
llecolutioo: 1610)~00
~
I
:::·
======::'.
MJ(:vM-1'.Hi'H)
I
,,,..,
System settings menu
The first time the xploview software is started, the
default settings will be loaded, you may change these
settings manually in the system settings menu.
10
I
Device setup
If the image captured by the Digital Microscope was not
displayed by default, you can change this by selecting it
from the "Device" drop-down menu.
The resolution of images you capture can be changed from
the "Resolution" drop-down menu.
Timed shot setup
The frequency and duration of automatic images capture can
be adjusted under this option.
Movie setup
The resolution of videos you record can be changed from
the "Resolution" menu. You can also set a maximum file
size for each video.
Save setting
The default location for captured images or videos can be
changed under this option.
Language setting
The language of the xploview software can be changed under
this option.
11
Digital Viewer Properties
[V
ideo
··
·proc
)i
irij:i'
J
Camera
Control
7
.,to
!!rightness
-fr-
10
~ontrast
it--
.,.
tj.,e
-it-
~tt.xation
-n--
64
-=
---f)--
112
@amma
1)-
72
't_/hiteBalance
-n--
"600 ~
!!,!ddightComp
f)-
1
@ain
1)--
-
o
-
Color~able
e_o
werl.rie Frequency 50 Hz
...
(
AntiFld<e<
)
~
OQ
~
CM::]
I
Advanced settings
By clicking the "More..." button on the right of the system
settings menu, you will be able to manually adjust all of the
image settings. Note that the settings available may be
different, depending on your operating system.
Saved files
With the xploview application software opened, you can
locate the saved files folder by clicking the "More..." button
located on the left of the main software window.
12
I
Full screen
To activate the full screen mode, click the full screen button
located on the bottom right hand corner of the xploview
application software window.
To exit full screen mode, either double click on the screen, or
press the “Escbutton on the keyboard.
Care and maintenance
Keep the device dry and protect it from water or vapour.
Do not leave your device in a place with an extreme high
or low temperature.
Do not touch the device with a wet hand as it may damage
the device, or cause an electric shock to the user.
Do not use or store the device in dusty, dirty areas as its
moving parts may be damaged.
Do not use harsh chemicals, cleaning solvents or strong
detergents to clean the device. Wipe it with a soft cloth
slightly dampened in a mild soap-and-water solution.
13
I
Warning
Do not place lighted Digital Microscope upon the eye, doing
so may cause permanent eye damage.
Do not attempt to open or dismantle the Digital Microscope.
14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Carson MM-480 User guide

Type
User guide

Carson MM-480 is a digital microscope that offers an effective magnification of up to 65x on a 21-inch computer monitor. It connects to your computer via USB and is compatible with both Mac and PC. You can capture images and videos, and even use the timed shot feature to automatically capture images at regular intervals. The microscope also comes with two adapters for viewing different areas of the face and scalp.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI