VICE R
Users Manual rel 1.0
D.T.S. Illuminazione s.r.l. - ITALY
http://www.dts-lighting.it
VICE R
VICE R MR16
3
VICE R
D.T.S. Product Codes:
03.LVS001E01WB16 VICE R WHITE 3000K 65° lens RAL 9010 finish
LED technology
High-power single White LED; Colour temperature: 2700K / 3000K / 4000K / 5600K; 850 lm (3000K)
LEDs average lifespan: 75.000 hours (70% lumen output)
Optical units
65° lens
Control
On-Off or DMX 512
Protection
IP65 (unit front side)
Construction
VICE R is made on aluminium
Power supply
Up to 700mA CC PSU (On-Off operation) or Z Series PSU (DMX 512 control)
Electronic full-range 90-260Vac 50-60Hz
Power consumption
10W Max
Connections
2 poles cable (0,5 m length)
Operating ambient temperature
-10° / 40°
Weight
0,23 Kg
Dimensions
VICE R
4
VICE R MR16
D.T.S. Product Codes:
03.LVS002E99WB16 VICE R MR16 WHITE 3000K 65° lens
LED technology
High-power single White LED; Colour temperature: 2700K / 3000K / 4000K / 5600K; 850 lm (3000K)
LEDs average lifespan: 75.000 hours (70% lumen output)
Optical units
65° lens
Control
On-Off or DMX 512
Protection
IP65 (unit front side)
Construction
VICE R is made on aluminium
Power supply
Up to 700mA CC PSU (On-Off operation) or Z Series PSU (DMX 512 control)
Electronic full-range 90-260Vac 50-60Hz
Power consumption
10W Max
Connections
2 poles cable (0,5 m length)
Operating ambient temperature
-10° / 40°
Weight
0,23 Kg
Dimensions
VICE R
ACCESSORIES
• 700mA Constant Current LED PSU (D.T.S. Code 0502T031)
• 500mA Constant Current LED PSU (D.T.S. Code 0502T040)
• 350mA Constant Current LED PSU (D.T.S. Code 0502T032.1)
• Z8 LED Controller Screw terminals outputs (D.T.S. Code 03.LA.080.V2)
• Z8 LED Controller M12 outputs (D.T.S. Code 03.LA.075.V2)
• Z1 PLUS IP20 LED Controller (D.T.S. Code 03.LA.009P)
• Z1 PLUS IP65 LED Controller (D.T.S. Code 03.LA.009P.IP65)
6
IMPORTANT SAFETY INFORMATION
Fire prevention:
It is permissible to place the unit on normally flammable surfaces.
Suitable for mounting on normally flammable materials surfaces greater than 200°C with some
combustion time lag.
Safety:
The external surface of the unit may exceed 50°C, never handle the unit until at least 5 minutes
Have elapsed since the unit was turned off.
Never install the unit in an enclosed area lacking sufficient air flow.
The ambient temperature should not exceed 40°C and should not be lower than -10°C.
CONNECTION
VICE R and VICE R MR16 are provided with a 2 poles cable (0,5 m length).
The maximum distance between CC PSU and the unit should not exceed 15 meters.
The maximum distance between Z Series PSU and the unit should not exceed 100 meters.
V+
(Red)
V-
(Black)
V+
(Red)
V-
(Black)
VICE R VICE R MR16
VICE R
WIRING DIAGRAMS
7
LED+ (Red)
LED- (Black)
90-260Vac
IN
700mA CC PSU
(D.T.S. Code 0502T031)
700mA CC PSU
(D.T.S. Code 0502T031)
L (Brown)
N (Blue)
V-
(Black)
V+
(Red)
48V
700mA CC
OUT
V-
(Black)
V+
(Red)
V-
(Black)
V+
(Red)
IMPORTANT:
The maximum number of VICE R or
VICE R MR16 connectable to a 350mA,
500mA or 700mA CC PSU is 3 pcs
serial wired.
The maximum distance between the
CC PSU and the unit should not exeed
15 meters.
Never connect or disconnect the unit
when the CC PSU is turned on.
VICE R
WIRING DIAGRAMS
8
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
R+ R-
G+
G-
B+
B-
LEDs Output
1
2
3
4
5
6
W+
7
W-
8
8 poles screw terminal
1---------PIN---------8
To R+
To R-
To G+
To G-
To B+
To B-
To W+
To W-
Z1 PLUS PSU
(D.T.S. Code
03.LA.009P)
IR
SENSOR
1=GND
2=VCC
3=RX IR
1=GND
2=VCC
3=RX IR
1--2--3
3 poles plug-in
screw connector
6 poles Female (RJ12)
1
6
1=GND
2=VCC
3=RX IR
4=Not used
5=Not used
6=Not used
1=GND
2=VCC
3=RX IR
The maximum number of VICE R or VICE R MR16 connectable to each Z1 PLUS LED Channel
output is 3 pcs serial wired.
The maximum distance between the Z1 PLUS LED PSU and the unit should not exeed 100
meters.
Never connect or disconnect the unit when the PSU is turned on.
VICE R
Z8 LED PSU
Screw terminals outputs
(Code 03.LA.080.V2)
R+ R-
G+
G-
B+
B-
1
2
3
4
5
6
8 poles screw terminals
1---------PIN---------8
W+
7
W-
8
LEDs OUT 2
LEDs OUT 3
LEDs OUT 4
LEDs OUT 5
LEDs output
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
To R+ To R- To G+ To G- To B+ To B-
To W+
To W-
The maximum number of
VICE R or VICE R MR16
connectable to each Z8
LED Channel output is
3 pcs serial wired.
The maximum distance
between the Z8 PSU and
the unit should not exeed
100 meters.
Never connect or
disconnect the unit when
The PSU is turned on.
WIRING DIAGRAMS
9
VICE R
The information contained in this publication has been carefully prepared and checked.
However, no responsibility will be taken for any errors. All rights are reserved and this document
cannot be copied, photocopied or reproduced, in part or completely, without prior written consent
from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its
products without prior notice. D.T.S. assumes no responsibility for the use or application of the
products or circuits described herein.
D.T.S. Illuminazione s.r.l - Via Fagnano Selve 10-12-14 47843 - Misano Adriatico (RN) Italy
Tel. +39 0541 611131 Fax +39 0541 611111 [email protected] www.dts-lighting.it
0517I254
*0517I254*
MADE IN ITALY
ISO 9001:2008
D.T.S. quality system
is certified to the
ISO 9001:2008 standard
D.T.S. products are designed
and manufactured at the D.T.S.
plants in italy
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

DTS VICE R User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI