Medallion NS6BD-KA User guide

Type
User guide

This manual is also suitable for

QUICK REFERENCE DATA
NS6BD Series - Residential Split System Air Conditioner
Table 2. Thermostat Wire Gauge
Thermostat
Wire Gauge
Recommended T-Stat Wire
Unit to T-Stat (Length in FT)
2-Wire
(Heating)
5-Wire
(Heating/Cooling)
24 55 25
22 90 45
20 140 70
18 225 110
Figure 1. Clearance Requirements
2” Mounting Pad
48”
24" for
Service Access
12" or 18”
See Note
12" or 18”
See Note
DO NOT
OBSTRUCT
TOP OF UNIT
NOTE: Units require full perimeter clearances.
Installer must maintain 18” between two units
or 12” between single unit and structure.
6” from Building
or Structure
Table 3. Unit Dimensions
MODEL
NUMBER
HEIGHT
(H)
WIDTH
(W)
DEPTH
(D)
NS6BD-018KA 27 1/2" 22 3/4" 22 3/4"
NS6BD-024K 27 1/2" 22 3/4" 22 3/4"
NS6BD-030K 27 1/2" 22 3/4" 22 3/4"
NS6BD-036K 35 1/2" 22 3/4" 22 3/4"
NS6BD-042KA 27 1/2" 30 3/4" 30 3/4"
NS6BD-048KA 27 1/2" 30 3/4" 30 3/4"
NS6BD-060KA 31 1/2" 30 3/4" 30 3/4"
D
W
H
Model NS6BD Shown
Table 1. Electrical Specifications & Physical Data
MODEL NUMBER NS6BD- 018KA 024K 030K 036K 042KA 048KA 060KA
Electrical
Data
Volts-Cycles Phase (1) 208/230-60-1
Total Amps 8.2 10.3 10.8 16.4 19.4 23.2 27.8
Delay Fuse Max. (2) 15 20 20 35 40 50 60
Min. Circuit Ampacity 10.1 12.7 13.3 20.1 23.9 28.7 34.4
Component
Data
Coil
Area 10.0 10.0 10.0 13.3 15.3 15.3 17.9
Rows-FPI 1-23 1-23 1-23 1-23 1-18 1-18 1-18
Tube Dia. Microchannel
Fan Motor
Type PSC
Amps 0.35 0.7 0.7 1.4 1.5 1.5 1.5
HP 0.05 0.1 0.1 0.25 0.25 0.25 0.25
Compressor
Data
RLA 7.8 9.6 10.1 15.0 17.9 21.8 26.4
LRA 45 61 60 88 112 117 134
REFRIGERANT SUCTION LINE O.D
NOTE: Liquid line is 3/8” O.D. for entire length.
15 - 24 ft. 3/4” 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
25 - 39 ft. 3/4” 3/4” 3/4” 7/8” 7/8” 7/8” 1-1/8” (4)
40 - 75 ft. 3/4” 3/4” 3/4” 7/8” 7/8” 7/8” 1-1/8” (4)
REFRIGERANT CHARGE
R-410A in ounces for outdoor unit & 15' Lineset. (5)
43 52 54 59 59 60 69.6
APPROXIMATE WEIGHT (LBS.)
Net 109 113 116 135 179 179 188
Ship 114 118 121 140 187 187 197
(1) Operating Voltage Range: 187v min. — 253v max.
(2) HACR Type Circuit Breakers may be used.
(3) Requires 7/8" to 3/4" reducer from line to unit.
(4) Requires 7/8" to 1-1/8" reducer from line to unit.
(5) Additional charge for line sets above 15 feet. Values
based on suction line as follows with 3/8" liquid line.
(a) 3/4" = 0.6 oz. per additional foot.
(b) 7/8" = 0.7 oz. per additional foot.
(c) 1 1/8" = 0.8 oz. per additional foot.
2
Instructions:
1. Find the column for the model of outdoor unit that is being installed.
2. Find the row for the model of the indoor unit that is being installed.
3. Find the cell in the table in which this row and column meet. In this cell
the appropriate orifice / TXV and charge addition for this match are listed.
If the text in this cell is BOLD, then a change of orifice is necessary.
4. If a change in restrictor is necessary, then the appropriate restrictor will
already be supplied with the outdoor unit.
Examples:
• FortheNS6BD-024K/B6BMM024K-Bmatch,theappropriaterestrictor
isthe.055”and5ouncesofchargewillneedtobeadded.(CHANGEIN
CHARGE)
• FortheNS6BD-042K/GB5BMM042K-Bmatch,therestrictorwillneed
tobechangedtothe.072”,andnoadditionalchargeneedstobeadded.
(CHANGEINRESTRICTOR)
Table 4. Restrictor or TXV / Charge Addition (Oz)
ID Restrictor Installed With ID Unit
MODEL NUMBER: NS6BD 018KA 024K 030K 036K 042KA 048KA 060KA
ID RESTRICTOR SUPPLIED WITH OD UNIT: 0.050, 0.054 0.055 0.058, 0.061 0.067, 0.069 0.071, 0.072 0.076, 0.077 0.087
OUTDOOR UNIT BOM CHARGE (OZ.) 43 52 54 59 59 60 69.6
MODELS
SUPPLIED
WITH ID
REQUIRED RESTRICTOR
(OR TXV / CHARGE ADDITION (OZ) / RATED AIRFLOW (SCFM))
GB5BM-0
GB5BM-024K-A 0.055 --
0.055
(26 / 875)
-- -- -- -- --
GB5BM-024K-B 0.055 --
0.055
(26 / 900)
-- -- -- -- --
GB5BM-030K-A 0.065 -- --
0.065
(26 / 750)
-- -- -- --
GB5BM-030K-B 0.065 -- --
0.065
(26 / 875)
-- -- -- --
GB5BM-036K-B 0.073 -- -- --
0.073
(30 / 1140)
-- -- --
GB5BMM
GB5BMM024K-A 0.055 --
0.055
(5 / 700)
-- -- -- -- --
GB5BMM024K-B 0.055 --
0.055
(5 / 715)
-- -- -- -- --
GB5BMM030K-A 0.062 -- --
0.058
(7 / 915)
-- -- -- --
GB5BMM030K-B 0.062 -- --
0.058
(7 / 915)
-- -- -- --
GB5BMM042K-B 0.074 -- -- --
0.069
(2 / 1225)
-- -- --
B5BM-X
B5B(M,V)-X24K-A 669564 --
669564
(26 / 875)
-- -- -- -- --
B5B(M,V)-X24K-B 669564 --
669564
(26 / 900)
-- -- -- -- --
B5B(M,V)-X30K-A 669565 -- --
669565
(26 / 750)
-- -- -- --
B5B(M,V)-X30K-B 669565 -- --
669565
(26 / 875)
-- -- -- --
B5B(M,V)-X36K-B 669566 -- -- --
669566
(30 / 1140)
-- -- --
B6BMM0
B6BMM024K-A 0.055
0.055
(0 / 605)
0.055
(5 / 700)
-- -- -- -- --
B6BMM024K-B 0.055
0.055
(0 / 605)
0.055
(5 / 715)
-- -- -- -- --
B6BMM030K-A 0.062 -- --
0.058
(7 / 915)
-- -- -- --
B6BMM030K-B 0.062 -- --
0.058
(7 / 915)
-- -- -- --
B6BMM042K-B 0.074 -- -- --
0.069
(2 / 1225)
0.072
(0 / 1370)
-- --
B6BMM048K-B 0.079 -- -- -- -- --
0.079
(2 / 1355)
--
B6BMM048K-C 0.079 -- -- -- -- --
0.079
(2 / 1630)
--
B6BMM060K-C 0.087 -- -- -- -- -- --
0.087
(0 / 1950)
NOTES:
• The charges listed are only valid for the standard 15’ lineset.
• Numberslistedas0.***arerestrictordiameters,whilenumberslisted
as669***areTXVpartnumbers.
3
Instructions:
1. Find the column for the model of outdoor unit that is being installed.
2. Find the row for the model of the indoor unit that is being installed.
3. Find the cell in the table in which this row and column meet. In this cell
the appropriate orifice / TXV and charge addition for this match are listed.
If the text in this cell is BOLD, then a change of orifice is necessary.
4. If a change in restrictor is necessary, then the appropriate restrictor will
already be supplied with the outdoor unit.
Examples:
• FortheNS6BD-024K/B6BMM024K-Bmatch,theappropriaterestrictor
isthe.055”and5ouncesofchargewillneedtobeadded.(CHANGEIN
CHARGE)
• FortheNS6BD-042K/GB5BMM042K-Bmatch,therestrictorwillneed
tobechangedtothe.072”,andnoadditionalchargeneedstobeadded.
(CHANGEINRESTRICTOR)
Table 4. Restrictor or TXV / Charge Addition (Oz) - Continued
ID Restrictor Installed With ID Unit
MODEL NUMBER: NS6BD 018KA 024K 030K 036K 042KA 048KA 060KA
ID RESTRICTOR SUPPLIED WITH OD UNIT: 0.050, 0.054 0.055 0.058, 0.061 0.067, 0.069 0.071, 0.072 0.076, 0.077 0.087
OUTDOOR UNIT BOM CHARGE (OZ.) 43 52 54 59 59 60 69.6
MODELS
SUPPLIED
WITH ID
REQUIRED RESTRICTOR OR TXV / CHARGE ADDITION (OZ) / RATED AIRFLOW (SCFM)
B6BW
B6BW-018K(*) 0.056
0.050
(3 / 620)
-- -- -- -- -- --
B6BW-024K(*) 0.057 --
0.057
(0 / 850)
-- -- -- -- --
B6BW-030K(*) 0.060 -- --
0.060
(0 / 950)
-- -- -- --
B6BW-036K(*) 0.069 -- -- --
0.069
(0 / 1080)
-- -- --
C5
C5(Q,D)A-X25U-B 669564 --
669564
(26 / 800)
-- -- -- -- --
C5(Q,D)A-X30U-B 669565 -- --
669565
(26 / 900)
-- -- -- --
C5(Q,D)A-X36U-B 669566 -- -- --
669566
(30 / 1140)
-- -- --
C5(Q,D)A-X37U-B 669566 -- -- --
669566
(30 / 1140)
-- -- --
C8
C8(B,D)AM01830U-B 0.061
0.054
(24 / 650)
0.055
(0 / 805)
0.061
(3 / 930)
-- -- -- --
C8(B,D)AM036U-B 0.067 -- -- --
0.067
(2 / 1245)
-- -- --
C8(B,D)AM042U-B 0.071 -- -- -- --
0.071
(7 / 1290)
-- --
CM4
CM4Q-53U TXV -- -- -- --
TXV
(36 / 1250)
-- --
CM4Q-54U TXV -- -- -- --
TXV
(36 / 1250)
TXV
(43 / 1450)
TXV
(36 / 1450)
CM4Q-56U TXV -- -- -- -- --
TXV
(43 / 1600)
TXV
(36 / 1600)
NOTES:
• The charges listed are only valid for the standard 15’ lineset.
• Numberslistedas0.***arerestrictordiameters,whilenumberslistedas669***areTXVpartnumbers.
Specifications & illustrations subject to change without notice or incurring obligations.
O'Fallon, MO | Printed in U.S.A. (11/12)
7095390 (Replaces 7093180)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Medallion NS6BD-KA User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI