INSTRUCTIONS
HIPPO Deluxe
Room Steam Vaporiser
Congratulations on your purchase of the HIPPO Deluxe Room Steam Vaporiser.
Before using this appliance, read the following instructions carefully as they contain important information
on use, safeguards and maintenance. Always keep this instruction leaflet in handy place for easy reference.
The appliance must only be used for the intended purpose according to these instructions.
Observe the warnings on important precautions.
Eliminate the packaging properly.
IMPORTANT PRECAUTIONS
Before using the HIPPO Deluxe Room Steam Vaporiser for the first time, check for any sign of damage
either to the appliance or its power cord. If any damage is observed, DO NOT USE and return appliance
to place of sale.
WARNING: HOT STEAM is emitted from this appliance.
The HIPPO Deluxe Room Steam Vaporiser must be used under strict supervision of an adult who has read
and familiarised themselves with the following instructions to avoid the possibility of scalding. Do not use
near children, disabled persons and pets. Keep packaging materials like plastic bags out of reach of
children.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Use this unit only as described in this manual. Other uses not recommended may cause fire or electric
shock.
This appliance is intended for household use ONLY and not for commercial, industrial or outside use.
Position the appliance on a flat, stable, water-resistant surface.
Do not use this appliance near bath-tubs, washbasins, large water receptacles or expose it to rain and
moisture.
Do not expose to outside elements or direct sunlight.
Do not immerse base in water and ensure that no water enters into appliance’s interior.
Do not block or obstruct air vents. Keep ventilation openings free from dust. Never drop or insert any
objects into any of the openings.
Do not place the appliance directly on furniture, carpets or wooden floors.
Do not carry nor pull the appliance by the power cord.
Do not wind the power cord around the appliance.
Appliances fitted with a water reservoir can lead to water damages. Before every usage, please check
that the lid of the tank is securely closed, that the tank has no cracks or damages, and that the
membrane valve closes properly.
Do not direct the steam flow towards furniture, walls or floors.
Do not move or handle the appliance while in use and avoid bumping into it.
Do not touch the power cord with wet hands, move the appliance or switch on when in bare feet.
Never immerse the appliance in water.
•Should the appliance accidentally fall into the water, immediately disconnect the plug from the power
socket before removing from water. Do not use it until it has been inspected or serviced by an authorised
service centre.
Always let the appliance cool down and disconnect plug from power socket before cleaning or refilling
with water.
Ensure that the appliance is empty of water and preferably dry before storing away.
Discard any residual water and rinse out before refilling the tank.
1
Periodically carry out maintenance and cleaning operation as detailed in Maintenance and Cleaning
Section.
Do not operate the appliance unless the aromatic container is in place. All components of the appliance
must always be installed as per the description before it is operated.
Do not add any medications into the water tank or aromatic container.
Do not use hot water.
Use only TAP WATER.
Aromatic oils must never be added to the water in the reservoir.
Do not over fill the aromatic container as the spill may over flow into the water reservoir. Only a few
drops of essence is required to obtain the desired effect.
Plug the appliance into an electrical socket with the same voltage as shown on the rating label. Do
not connect appliance to a direct current (DC) supply.
Repairs must be carried out by an authorised service Centre. Unauthorised repairs may void warranty
and could be a potential electrical hazard.
INSTRUCTIONS FOR USE
1. Grasp the handle of the water tank firmly and
remove it from the base (Fig. 1).
2. Remove the cap from the water reservoir by
turning it counter-clockwise (Fig. 2).
Fill the water reservoir with (Max. 3.8 L) tap water
(cool water, not warmer than 40°C).
After filling the water reservoir with water secure the
reservoir cap firmly.
3. Carefully place the water reservoir back into the base.
4. Insert the essence (if desired) into the aromatic
container (b) (Fig. 3).
- Do not put the essence directly into the water.
- Do not overfill the aromatic container
or spill any into the Steam Chamber (c).
- Do not operate unit without the aromatic
container in place.
2
Fig.2
Fig.3
B
C
Fig.1
5. Connect the power cord to a power socket.
6. To turn the unit on, turn the Switch (L) clockwise,
to switch off turn anti clockwise.
The indicator lamp (m) will illuminate
green when the appliance is switched On (Fig. 4).
7. The appliance will take approx 4 minutes to heat
up and for steam to start being emitted from discharge opening.
8. WARNING: Do not direct the steam
jet towards objects, floors or walls (Fig. 5).
9. When the water in the reservoir has been exhausted, the water indicator lamp EMPTY (i) will illuminate
in red and the HIPPO Deluxe will shut off automatically.
10. Switch off the appliance, disconnect the power cord and let it cool off for 15 minutes before refilling
the water reservoir.
11. Always rinse the water reservoir after each use.
Caution!
The steam is very hot. Please keep your feet and hands away from the steam discharge opening. Do
not operate the air humidifier close to children. Danger of burning!
COMPONENT LIST
Water reservoir handle
Aromatic container
Steam chamber
Water reservoir (Max capacity 3.8 litre)
Heating chamber
Base
Heater cone
Heater cone release
Water level indicator lamp (EMPTY)
Switch (ON/OFF)
Operation indicator lamp (ON)
A
B
C
D
E
F
G
H
I
L
M
A
B
C
D
F
I
L
M
E
3
Fig.4
Fig.5
M
L
I
40cm40cm
40cm
EMPTY
OFF
ON
ON
MAINTENANCE and CLEANING
Disconnect the power cord from the power outlet and allow the appliance to cool before cleaning.
When not used for extended periods of time, place appliance in plastic bag, away from dirt and dust
and store in a cool dry area.
Failure to carry out maintenance and cleaning may cause excessive build up of scale on the heating
element preventing the unit from operating correctly. This may cause a false EMPTY water level warning and
for the RED light to illuminate even when the water tank is full.
Daily Maintenance:
Remove water reservoir from base (d) and rinse it
with warm water thoroughly a couple of times.
Repeat this process every time before refilling the
appliance with water prior to using. Wipe accessible
surfaces of the water reservoir with a soft cloth.
Remove the Aromatic container from the Steam
Chamber (c) (Fig. 6). Using the Heating Cone release (Fig. 7),
release the Steam Chamber (Fig. 8) from the Base.
Wipe the Aromatic container, Steam Chamber and
Removable Heating Cone (Fig. 9) clean with a soft damp cloth.
• Clean the base with a soft damp cloth. Ensure the
heater and heater chamber is cool before wiping dry.
- DO NOT use abrasive cleaners or brushes.
- DO NOT leave water in the Water Reservoir when the
unit is not in use. This may result in bacteria growth in the reservoir.
Fig.7
Fig.8
C
Fig.6
Fig.9
G
H
4
5
Weekly Maintenance:
•Thoroughly clean humidifier every week as described in Daily Maintenance.
Remove the water reservoir (d), the steam chamber (c), and the heating cone (g) from the appliance
and rinse all parts with vinegar water (25% vinegar / 75% water). Rinse thoroughly with clean water
after that.
•Remove any residual water from the water reservoir. Fill the reservoir with a mixture of 25% vinegar
(950ml) and 75% water (2850ml) and leave for 20 minutes to remove possible mineral deposits. Drain
vinegar water and rinse thoroughly with clean water.
Fill the heating chamber (e) with vinegar (50% vinegar / 50% water) and leave it to take effect for 20
minutes. Drain any residual water from the heating chamber and dry with damp soft clean cloth.
WARNING: Do not submerge or rinse the base in water.
- Do not use steel wool, scouring agents or abrasive material.
- Dry all parts properly.
- Reassemble the appliance as shown in the instruction manual.
Disinfecting the Removable Heating Cone and Water Reservoir:
Thoroughly clean humidifier every week using a solution of bleach and water (1 tea spoon of bleach
in 3.8 litre of water). Fill the reservoir partially with this solution and let it stand for 20 minutes shaking the
water reservoir vigorously every few minutes. Drain and rinse the reservoir with clean water until the
bleach smell is gone.
The Heating Cone, Aromatic container, and Steam Chamber are dishwasher safe.
N.B.: Place on the top shelf of the dishwasher only.
End of Season Maintenance:
Thoroughly follow Weekly Maintenance directions above. Make sure all parts of the humidifier are dry
before storing.
Leave the reservoir cap partially loosened during storage to prevent the reservoir cap and gasket from
sticking together.
Clean the reservoir and base after a long period of storage.
6
TROUBLE SHOOTING
PROBLEM
The switch is ON, but the
Operation indicator lamp (ON)
is off
No Mist
Condensation forms around
the humidifier or windows
Empty water level indicator
lamp (EMPTY) illuminates
Water overflows from the tank
CAUSE
Unit is not plugged in.
No power at the outlet.
No water in the reservoir.
Unit is not level.
Mineral deposits are on the
Heater or Removable Heat
Cone.
Water Reservoir was washed
with detergent.
Mist intensity is too high for the
room size or pre-existing
humidity level.
Water Reservoir is empty.
The unit was not switched off
and let cool after refilling the
water reservoir.
The heating element is
encrusted with scale and the
protection thermostat has
tripped.
Tank may be leaking.
Tank Cap is loose.
SOLUTION
Plug the unit in.
Have the circuits, fuses, and
test outlet with a tester.
Fill reservoir with water.
Place on a level surface
Clean the Heater and
Removable Heat Cone as
specified in the Weekly
maintenance.
Rinse thoroughly with clean
water and dry.
Open room door gradually
until condensation stops.
Refill water reservoir
Disconnect the power cord.
Switch off the unit, and let it
cool off for 15 minutes. Then
switch the unit on.
Unplug the power cord and
carry out the cleaning
procedure.
Check before every usage
that the lid of the tank is
securely closed, that the tank
has no cracks or damages,
and that the membrane valve
closes properly.
Tighten the Tank Cap.
TECHNICAL SPECIFICATIONS
The appliance is suitable for rooms up to 25 m
2
Voltage 230V~ 50Hz
Watt: 260
Tank capacity: 3.8 l approx.
Operating time: up to 10 hours
Dimension (cm): 27L x 22W x 32H
Weight (empty): 1.85 Kg
Manufactured to comply with EN 60335-2-98:2003+A1:2005+A2:2008,
used in conjunction with EN 60335-1:2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008.
(AS/NZS 3350.2.98 : 1998 A1)
Approval Number N21454
SYMBOLS
Alternating current
Warning: follow the “Instructions for use”
Warranty: 5 years from date of purchase; does not include damage due to misuse, negligence or
calcification of the heating element. Please retain your purchase receipt, as proof of purchase must be
presented if making a claim under warranty.
Ebos Group P/L reserves the right to make technical changes to this product with out prior notice.
For service, return the unit to your place of purchase
or telephone the Consumer Support centre 1300 300 330
Distributed by Ebos Group Pty Ltd
Unit 2, 109 Vanessa Street
Kingsgrove NSW 2208
ABN 77 000 060 364
10855D0-0 rev. 08/2010
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Allersearch HIPPO Deluxe Instructions Manual

Category
Humidifiers
Type
Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI