C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
©2006 ADTRAN, Inc.
All Rights Reserved.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails
while in service. Warranty information can be found online at www.adtran.com/warranty
.
MX2820
19-Inch
Chassis
P/N: 1186001E1
CLEI: M3M1R00B_ _
NOTE: PWR = Respective –48 VDC or ±24 VDC source, RET = respective return
13. Insert the appropriate fuses into the fuse panel.
14. Using a voltmeter, verify that the operating voltage is within specifications for A and B power.
15. Remove appropriate fuses from panel and replace the metal cover that was removed in step 5.
16. Insert appropriate fuses into panel, and if not done in step 2, attach cable tie bar.
17. Connect 10/100Base-T Ethernet and NTWK MGMT X.25 interfaces.
18. Route DSX-3 coax and tie to upper tie bar.
19. Route DSX-1 IN cables below upper tie bar and tie to upper tie bar.
20. Route DSX-1 OUT cables beneath lower tie bar and tie to lower tie bar.
OPERATIONAL SPECIFICATIONS
COMPLIANCE
The MX2820 Chassis complies with UL 60950, NEBS Level 3, and GR-1089-CORE. The MX2820 Chassis is
intended for installation in Restricted Access Areas only. The MX2820 Chassis meets the EU’s RoHS Directive
2002/95/EC and/or applicable exemptions. See www.adtran.com
for further information on RoHS/WEEE.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this
equipment.
CAUTION: The DSX-1, DSX-3, and 10/100Base-T Ethernet circuits are not to be connected to outside plant
facilities.
Specification Description
Operating Voltage –48 VDC Systems: –42 VDC to –56 VDC
–24 VDC Systems: –22 VDC to –27 VDC
+24 VDC Systems: +22 VDC to +27 VDC
Operating Temperature: –40ºC to +50ºC without fans
–40ºC to +65ºC with fans
Storage Temperature –40ºC to +85ºC (Relative humidity to 95 percent, noncondensing)
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) – –
Installation Code (IC) A –
DESCRIPTION
The MX2820 19-Inch Chassis (P/N 1186001E1) houses multiple M13 multiplexers that consolidate T1/E1 signals
into T3 circuits. The Chassis houses seven redundant M13 multiplexers. The Chassis also houses a single System
Controller Unit (SCU) that provides management capabilities to the MX2820 system.
Features of the MX2820 system include the following:
♦ 1-to-1 redundancy
♦ Hot-swappable MUX cards
♦ Embedded SNMP and Telnet management
♦ Simplified configuration through the VT100 terminal menu structure
♦ Meets the requirements for NEBS Level 3 compliance
TURN-UP STEPS
After unpacking the unit, inspect it for damage. If damage is noted, file a claim with the carrier and then contact
ADTRAN. For more information, refer to the warranty.
1. Attach mounting ears.
2. Attach cable tie bar, if necessary.
3. Mount chassis in rack.
WARNING: Care should be taken not to upset the stability of the equipment rack.
4. Remove appropriate fuses from fuse panel.
5. Remove metal cover from the right side of the back panel.
NOTE: Silk-screen on the metal cover references the following connections.
6. Wire wrap
CHN posts and MIN alarm relay posts and then route the wire downward.
7. If STS-1, wire wrap
CLKB and CLKA posts and then route the wire downward.
8. Wire wrap
ACO posts and then route the wire downward.
9. Wire wrap
AUX1, AUX2, and AUX3 alarm input posts and then route the wire downward.
10. Wire wrap
MAJ and CRIT alarm posts and then route the wire downward.
11. Connect the frame ground on the barrier strip.
CAUTION: Per GR-1089-CORE October 2002, Section 9, MX2820 system is designed and intended only for
installation in a DC-C (common) bonding and grounding system. The chassis ground wire must be of
equal or greater ampacity than the wire connected to the VDC return. The MX2820 system is not
intended or designed for installation in a DC-I (isolated) bonding and grounding system.
NOTE: A readily accessible disconnect device, such as a rackmount fuse and alarm panel that is suitably approved
and rated should be incorporated in the fixed wiring.
NOTE: Connect to a reliably, grounded VDC source, which is electrically isolated from the AC source.
12. Connect
RET B, PWR B, RET A, and PWR A on the barrier strip.
61186001E1-22C
0612
MX2820
19-Inch Chassis
*61186001E1-22C*
C
R
A
F
T
1186003
SCU
ACO
ALM
ACT
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
1A
CLKB
CLK A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
1B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
2A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
2B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
3A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
3B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
4A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
4B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
5A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
5B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
6A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
6B
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
7A
1186002
MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
7B
1186011
CLK
1186011
CLK
MX 2820
1186001L1