Keating MG-4 E Datasheet

Type
Datasheet

This manual is also suitable for

SPECIFICATIONS
FAX: 708-246-3100PHONE: 708-246-30001-800-KEATINGMcCOOK, IL, 60525 USA8901 WEST 50th STREETKEATING OF CHICAGO, INC.
ww w.keatingofchicago.com
PROJECT
QUANTITY
ITEM NO.
DATE
APPROVAL
SIGNATURE
Hot Plate
PRINTED IN THE USA 07/2011 Hotplate_2011
Hot Plate
Keating heavy duty Hot Plates are designed to provide the
energy input needed to heat up quickly, and the control to
maintain temperature.
Performance
The MG-2 and MG-4 gas models deliver 15,000 BTU/hr.
input per burner at 4" water column pressure. The Keating
electric models provide 2600 watts per element operating
on a 240 volt line.
Compact size
The MG-2 is only 13" wide by 24" or 30" deep. The MG-4
is 26" wide. A perfect size for equipment stands or in a
Keating Custom Line-Up, the Hot Plate complements any
kitchen decor.
Rugged design
The Hot Plate gas models feature removable grates and
drip pans and stainless steel burners. Electric models
utilize heavy duty coil elements which are 7-1/2" in
diameter.
Options
Options include stainless steel fi nish, extended fronts,
matching dummy cabinets, spark ignition for Natural Gas
Hot Plates, and 480 voltage (for 30" only).
Available in gas or electric, with two
or four burners
Gas model features 15,000 BTU/hr. input
Electric model features infi nite controls
at 240V per element
Compact size is perfect for Kiosks
Stainless Steel Finish
Extended Fronts
Matching Dummy Cabinets
Spark Ignition for
Natural Gas Hot Plates
480 Voltage (for 30" Only)
Standard Features:
Options:
As continuous product improvement occurs, specifi cations
may be changed without notice.
9902091 9902091
MG-2 Electric
MG-2 Gas
FAX: 708-246-3100PHONE: 708-246-30001-800-KEATINGMcCOOK, IL, 60525 USA8901 WEST 50th STREETKEATING OF CHICAGO, INC.
ww w.keatingofchicago.com
Hot Plate
PRINTED IN THE USA 07/2011 Hotplate_2011
Hot Plate
GAS MODEL SPECIFICATIONS
The Keating Hot Plate is available with 2 (MG 2) or 4 (MG 4)
burners in a cabinet with a splashback. Each burner is rated
at 15,000 BTU/hr.
Burner - Stainless Steel burners, rated at 15,000 BTU/hr.
The MG 4 has four burners.
Grates - Cast iron grates, removable for cleaning.
Burner Control - Manual gas valves (infi nite controls) are
mounted in the front with constant pilots. Spark ignitors are
available.
Drip Tray - The drip tray is removable from the front for easy
cleaning.
Gas Connection - 3/4" NPT male connection located in the
rear of the unit.
As continuous product improvement occurs, specifi cations may be changed without notice.
ELECTRIC MODEL SPECIFICATIONS
The Keating Hot Plate is available with 2 (MG 2 E)
or 4 (MG 4 E) two coil elements in a cabinet with a
splashback. Each element is controlled by a sepa-
rate infi nite control, and is rated at 2,600 watts at
240 volts.
Elements - 7 1/2" coils encased in Stainless Steel
top rated at 2,600 watts at 240 volts single phase.
Element Control - Infi nte controls are mounted in
the front of the unit.
Drip Pan - The drip pan is removable from the top
for easy cleaning.
Electrical Connection - Located at the rear of the
unit per local and national codes.
Note: Special order may include Spark Ignition (gas models) and 480 voltage for 30" only.
GAS/ELECTRICAL REQUIREMENTS AND DIMENSIONS*
BURNER/ BTU INPUT/ KW @ 240V AMPS @ 240V Height (A) Depth (B) Width Weight
MODEL ELEMENTS BURNER
MG 2 24 CP NAT GAS 2 15,000 16 5/8" 24 1/2" 13" 140 lbs.
MG 2 24 LP GAS 2 15,000 16 5/8" 24 1/2" 13" 140 lbs.
MG 2 E 24 208-240/1 2 5.2 22 16 5/8" 24 1/2" 13" 140 lbs.
MG 2 30 CP NAT GAS 2 15,000 16 5/8" 30 1/2" 13" 140 lbs.
MG 2 30 LP GAS 2 15,000 16 5/8" 30 1/2" 13" 140 lbs.
MG 2 E 30 208-240/1 2 5.2 22 16 5/8" 30 1/2" 13" 140 lbs.
MG 4 24 CP NAT GAS 4 15,000 16 5/8" 24 1/2" 26" 150 lbs.
MG 4 24 LP GAS 4 15,000 16 5/8" 24 1/2" 26" 150 lbs.
MG 4 E 24 208-240/1 4 10.4 43 16 5/8" 24 1/2" 26" 135 lbs.
MG 4 30 CP NAT GAS 4 15,000 16 5/8" 30 1/2" 26" 150 lbs.
MG 4 30 LP GAS 4 15,000 16 5/8" 30 1/2" 26" 150 lbs.
MG 4 E 30 208-240/1 4 10.4 43 16 5/8" 30 1/2" 26" 135 lbs.
*All Models have a 12" Working Height
INSTALLER - Check plumbing and gas codes for proper gas supply line sizing to sustain burner pressure when all gas
appliances are full on. Supply pressure must NOT be above 13.84" WC or gas valve damage may occur.
FRONT VIEW
SIDE VIEW
GAS / ELECTRIC MODELS
TOP VIEW FRONT VIEW TOP VIEW
GAS MODELS ELECTRIC MODELS
A minimum of 24" at the front of the unit should be allowed
for servicing and operation; a minimum of
6" on each side
and at the rear of each unit for combustible materials.
  • Page 1 1
  • Page 2 2

Keating MG-4 E Datasheet

Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI