GARO GC12EV40PMEDLMB User manual

Type
User manual

GARO GC12EV40PMEDLMB is a domestic consumer unit with advanced features for electric vehicle (EV) charging and electrical safety. It combines a 40A RCBO Type B with PME fault detection and load management capabilities. The device offers protection against electric shock and ensures that the EV charger is disconnected from live conductors within 5 seconds if the voltage exceeds 253V rms or drops below 207V rms. It also includes voltage and current relay settings for customizable load management. With an IP65 rating, the unit is suitable for outdoor installations.

GARO GC12EV40PMEDLMB is a domestic consumer unit with advanced features for electric vehicle (EV) charging and electrical safety. It combines a 40A RCBO Type B with PME fault detection and load management capabilities. The device offers protection against electric shock and ensures that the EV charger is disconnected from live conductors within 5 seconds if the voltage exceeds 253V rms or drops below 207V rms. It also includes voltage and current relay settings for customizable load management. With an IP65 rating, the unit is suitable for outdoor installations.

Domestic Consumer Units (18 Edition)
PME Fault detection - Type B RCBO - Load Management
Technical data GC12EV40PMEDLMB
Rated current 40A
Rated voltage 230 V AC
Frequency 50/60 Hz
Rated Conditional Short Circuit (Icc) Annex ZB: 16kA rms at 250V
Main Device 40A RCBO Type B
Additional Devices PME Fault detection & D L M
Operation 207V - 253V (4 seconds)
Degree of protection IP65
Total number of ways 12
Total Number of free ways 1
Height..mm (H) 246
Width..mm (W) 310
Depth..mm (D) 148
Ambient temperature (C) -25.....+55
Storage temperature (C) -35.....+55
Terminals 25mm
Material ABS
Standard EN 61439-3
Compliance with BS 7671
For EV chargers without DC leakage protection & PME fault detection
Warranty (Mechanical Components) 5 Years
Warranty (Electronic Components) 2 Years
Load Management Current 10 - 110 Amps
i
Y1
Red
Y2
BL
i = current
Split core CT
Maximum Current 100 Amps
Outside Diameter 45mm
Inner Diameter 24m
Lead lenght 500mm
Standard EN61010-1
EN61000-6-2
EN61000-6-3
Relay settings
Voltage relay: 1 OFF, 2 OFF, 3 ON, 4 OFF.
Current Relay: 1 OFF, 2 ON, 3 OFF, 4 ON, 5 ON, 6 ON.
HYS
LEVEL
0
Set to Max current Level 10 -100 Amps
DELAY 30secs
SHEETDRAWING No.
PROJECT No
CHECKNAMEDATEDESCRIPTION
PROJECT
=
+
NO
4 7 85 61 2 3
APPD
GC12EV40PMEDLMB1
& Load Management
MCU 40A Type B RCBO, PME Fault Detection
GC12EV40PMEDLMB
(ABS IP65)
310mm
246mm
148mm
INCOMING
EARTH
NOTE:
INCOMING (RCBO)
TERMINAL 4: PHASE
TERMINAL 2: NEUTRAL
EARTH BAR: EARTH
OUTGOING (CONTACTOR)
TERMINAL 1: EARTH
TERMINAL 3: PHASE
TERMINAL 5: NEUTRAL
CONT.
4P.
40A
VOLTAGE
RELAY
6A
B
TEST
RCBO B
C40A
CURRENT
LEVEL RELAY
MAIN CONSUMER UNIT
RED
BLACK
CT
MAINS CABLE
CONT.
4P.
40A
VOLTAGE
RELAY
6A
B
TEST
RCBO B
C40A
CURRENT
LEVEL RELAY
NL
CABLE
ENTRY
NL
E
TO CAR
CHARGER
4
2
A1
A2 86
31 75 42
31
14 A2
A1 11
18
A1
A2
15 Y2 Y1
IET BS:7671:2018
722.411.4 TN system (Amendment 1:2020)
(iv) Protection against electric shock in a single-phase installation is provided by a device which
electrically disconnects the vehicle from the live conductors of the supply and from protective earth
in accordance with Regulation 543.3.3.101(ii) within 5 s in the event of the utilisation voltage at the
charging point, between the line and neutral conductors, being greater than 253 V rms or less than
207 V rms. The device shall provide isolation and be selected in accordance with Table 537.4.
Equivalent means of functionality could be included within the charging equipment. Closing or
resetting of the device shall be possible only if the voltage between line and neutral conductors is in
the range 207 to 253 V rms.
Supplier/Tillverkare: GARO AB
Box 203
S-335 25 GNOSJO
Sweden Telephone:
Telefax:
+46 (0)370 33 28 00
+46 (0)370 33 28 50
Supplier established within EU/Ombud etablerad inom EG
Supplier of equipment /Materielslag : Consumer unit/Normcentral
Trade Mark/ Varumärke: GARO
Type Designation / Typbeteckning: G, C, GS, 4, 6, 8, 10, 12, 14,16,18, 21, 28, 32, EV, S,
R, C, PME, B , M, DLM, A, B.
We hereby declare that our product fulfils the requirements of following EC directives/
Vi intygar h
ä
rmed att vår produkt uppfyller krav enligt följande EU direktiv:
The following harmonised standards (latest edition) or technical specifications which comply with good engineering
practice
i
n safety matters in force within the EU have been used in the design:/
Följande harmoniserade standarder (senaste utgåva) eller tekniska specifikationer som uppfyller god säkerhetsteknik
praxis inom EG har använts i konstruktionen: SS EN 61439-3
The equipment conforms completely with the above stated harmonised standards or technical specifications./
Materielen överensstammer helt med ovan angivna harmoniserade standarder eller tekniska specifikationer.
Or/Eller
The equipment confirms only partially with the above stated harmonised standards or technical specifications but
complies with good practice in safety matters in force within the EU./
Materielen överensstammer endast delvis med ovan angivna harmoniserade standarder eller tekniska specifikationer,
men uppfyller god säkerhetsteknik praxis inom EG.
We have product surveillance according to CENELEC's harmonised requirements, documents CCA-201.
Garo AB 2018-06-14
Company/Företag Date/Datum
Sign/Underskrift
Environmental- and Quality Manager/Kvalitets- och Milj
ö
chef
Position/Befattning
Magnus Arvidsson
Name / Namnförtydligande
Dokument/documen
t
F
ö
rs
ä
kran om overensst
ä
mmelse/
Declaration of conformity
Utgava datum/edition date
2018-06-14
Avdelning/department
K
valite/Quality
Ansvarig/prepared
Magnus Arvidsson
Version
3
Sida/page
1 av/of 1
The Low Voltage Directive (LVD) 2014/35/EU I L
å
gsp
ä
nningsdirektivet (LVD) 2014/35/EU.
Electromagnetic compatibility (EMC) 2004/108/EU I Elektromagnetisk kompatibilitet (EMC) 2004/ 108/EG.
RoHS Directive (RoHS) 2011/65/EU I RoHS direktivet (RoHS) 2011/65/EG.
No electromagnetic compatibility (EMC) immunity or emission tests are required on the assembly/
Produkten inneh
ä
ller inte elektroniska apparater som p
å
verkas enligt rbehållen enligt direktivet
(EMC) 2004/108/EG.
  • Page 1 1
  • Page 2 2
  • Page 3 3

GARO GC12EV40PMEDLMB User manual

Type
User manual

GARO GC12EV40PMEDLMB is a domestic consumer unit with advanced features for electric vehicle (EV) charging and electrical safety. It combines a 40A RCBO Type B with PME fault detection and load management capabilities. The device offers protection against electric shock and ensures that the EV charger is disconnected from live conductors within 5 seconds if the voltage exceeds 253V rms or drops below 207V rms. It also includes voltage and current relay settings for customizable load management. With an IP65 rating, the unit is suitable for outdoor installations.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI