NEMAProtectionRating
Housing IP20
NEMAProtectionRating
Display IP65
PowerSupply 250VAC50/60Hz(10amp)
FireProtectionRating V‐0
PowerConsumption <3W
DisplayRange ‐45to120C
Accuracy +/‐0.5C
Resolution 0.1C
WIRINGDIAGRAM
ICONLEGEND
ICON MODE FUNCTION
On CoolingRelayOn
Flashing CoolingRelayDelayedStart
On HeatingRelayOn
On Alarm
oCoF On TemperatureUnit
SETTINGTHESETPOINT
1. PushandimmediatelyreleasetheSETkey.Thedisplaywill
showthesetpointvalue.
2. Usetheupanddownarrowkeystochangethesetpoint.
3. Wait6secondstoreturntothehomescreen.
RESUMEFACTORYDEFAULTSETTING
Pushthedownkeyfor1second.Whileholdingdownthedown
keyalsopushtheupkeyatthesametime.Oncetheupand
downkeyarebothdepressedthenreleasethedownkeyand
keepholdingtheupkeyforafurther6seconds.
CHANGINGTHEADVANCEDSETTINGS
FormoreadvanceduserstheMKIItemperaturecontrollerhas
asignificantlyadvancedsettingsmenuthatcanbeaccessed.
Theadvancedsettingsallowfurtherinstructionstobegivento
thecontrollersuchasdifferentcoolingstartdelaytimes,
tightertemperaturehysteresissettings,distillationcontrolor
evensequentialtemperaturesettings.Someoftheadvanced
settingsareshowinthetablebelow:
FunctionSetting Range Default
E3 Temphysteresis 0.1 ~10C 1C
E4 CoolingStartdelayatpoweron 0~10min 00
E5 CoolingStartdelay 0~10min 02
E6 Calibrationoffsetsetting ‐20C~+20C 00
t1 Delaytimebetweenheatingand
coolingturningon
0~30min 05
H1 Hightempalarm H2~120C 120
H2 Lowtempalarm ‐45C~H1 ‐45
H5 Alarmstartdelayatpoweron 00~180min 00
H6 Alarmdelaytime 00~180min 00
C1 Temperatureunit 00=oC
01=oF
00
d1 Advancedfunctionmode
(EXPLAINEDINDETAILBELOW)
00=Normal
01=Sequential
02=Distillation
00
d2 TimeUnit 00=Second
01=Minute
02=Hour
03=Day
01
d3 Timeallocatedtoeachsequential
step
00~200 01
SEQUENCIALTEMPSETTINGSBELOWBECOMEVISABLEWHENYOUSET
“d1”to“01”
F1 Sequential Temp1 ‐40~+120oC20C
F2 SequentialTemp2 ‐40~+120oC 20C
F3 SequentialTemp3 ‐40~+120oC 20C
F4 SequentialTemp4 ‐40~+120oC 20C
F5 SequentialTemp5 ‐40~+120oC 20C
F6 SequentialTemp6 ‐40~+120oC 20C
F7 SequentialTemp7 ‐40~+120oC 20C
F8 SequentialTemp8 ‐40~+120oC 20C
F9 SequentialTemp9 ‐40~+120oC 20C
F10 SequentialTemp10 ‐40~+120oC 20C
F11 SequentialTemp11 ‐40~+120oC 20C
F12 Sequential Temp12 ‐40~+120oC20C
1. Toaccesstheadvancedsettings(above)pushtheSETkey
for6secondsuntilE3flashes.
2. Usethearrowkeystonavigatetotheadvancedsettingand
thenusesetkeytoselecttheadvancedsettingthenuse
thearrowkeytochangetheadvancedsetting.
3. Aftertheadvancedsettingshavebeensetusethesetkey
toreturntotheadvancedsettingdisplayorjustwait6
secondstoreturntothehomescreen.Alternativelyifyou
wouldliketoreturntothehomescreenquicklysimply
pressthe“X”buttontoinstantlyreturntothehome
screen.
d1ADVANCEDFUNCTIONMODE
Theadvancedfunctionmodehasthreedifferentsettings:
d1=00–Thisisjustnormaloperation
d1=01–SequentialMode
Insequentialmodeaseriesofsettemperaturescanbe
setupsothetemperaturecontrolwillcyclethroughanumber
ofdifferentsettemperaturesbeforereturningtotheoriginal
settemp.Thiscanbeparticularlyusefulifyouwantedtoseta
fermentationtemperatureprofilesothatthetemperature
MKII Temp Controller