MAINTENANCE
• Before starting any kind of maintenance and repair operations, always disconnect.
• Maintenance only concerns the burner outlet cleaning, the possible replacement of the calibrated nozzle and the
replacement of the flexible hose, in the event of extended use.
• Air outlet and nozzle are on the device upper part so being easily accessible by removing the control box by means
of its 4 screws.
• Maintenance procedures are quite simple and do not require technical expertise.
Check the distance of the elec-
trode and the safety thermostat.
Intervene only if necessary.
PROBLEM CAUSE REMEDY
The motor does not start
The flame does not ignite
The flame extinguishes after
a few
seconds of ignition
The flame has a white
luminous outline
1. Faulty power supply cable
2. Faulty fan
3. Faulty switch
1. Excessive distance between electrode and burner
2. There is no gas
3. Faulty gas valve
1. Excessive distance between the temperature
2. Gas button not held down long enough
3. Faulty safety chain
1. Air fault in the burner
2. Excess of gas in the burner
1. Replace or repair
2. Replace or repair
3. Replace or repair
1. Adjust distance
2. Replace cylinder
3. Specialized work needed
1. Adjust distance sensor and the
burner
2. Keep the button pressed down
slightly longer (max 20 seconds)
3. Specialized work needed
1. Clean air inlet
2. Adjust pressure and/or
replace nozzle
TROUBLESHOOTING
Push button to
restore the safety
valve.
SCHEMA ELETTRICO - ELECTRICAL DIAGRAM - SCHEMA ELECTRIQUE - ELEKTRISCHE DIAGRAM
- DISENO ELÉCTRICO - ESQUEMA ELÉCTRICO - ΗΛΕΚΤΡΙΚΟ ΚΥΚΛΩΜΑ - ELEKTRISCH SCHEMA -
SĂHKÔTAULU - KOPPLINGSSCHEMA
ES PT EL
A Cable de alimentación Cabo de alimentação Καλώδιο τροφοδοσίας
B Interruptor Interruptor ∆ιακόπτης
C Válvula gas Válvula gás Βαλβίδα αερίου
D Piezoeléctrico Piezoeléctrico Πιεζοηλεκτρικό
E Cable piezoeléctrico Cabo piezoeléctrico Πιεζοηλεκτρικό καλώδιο
F Electrodo Eléctrodo Ηλεκτρόδιο
G Termopar Termo-par Θερµοζεύγος
H Termostato de seguridad Termóstato de segurança Θερµοστάτης ασφαλείας
K Motor ventilador Motor ventilador Κινητήρας Ανεµιστήρα
L Cable de masa Cabo de massa Καλώδιο γείωσης
M Electroválvula Válvula eléctrica Ηλεκτροβαλβίδα
NL FI SE
A Gasleiding Johto Matarkabel
B Schakelaar Katkaisin Brytare
C Regelventiel Kaasuventtiili Gasventil
D Piezo ontsteking Pietsosytytin Piezoelektrisk
E Kabel Pietsojohto Piezoelektrisk kabel
F Ontstekings elektrode Elektrodi Elektrod
G Thermisch koppel Lämpöanturi Termokors
H Thermostaat Liekinvarmistin kerhetstermostat
K Motor v.d. ventilator Puhaltimen moottori Fläktmotor
L Aarding Maadoitusjohto Jordkabel
M Schakel relais Magneettiventtiili Elektromagnetisk ventil
IT GB
A Cavo di alimentazione Power cable
B Interruttore Switch
C Valvola gas Gas valve
D Piezoelettrico Piezo lighter
E Cavo piezoelettrico Piezo cable
F Elettrodo Electrode
G Termocoppia Thermocouple
H Termostato di sicurezza Safety thermostat
K Motore ventilatore Ventilation motor
L Cavo di massa Earth wire
M Elettrovalvola Electrovalve
FR DE
A Câble alimentation Versorgungskabel
B Interrupteur Schalter
C Soupape à gaz Gasventil
D Piézo-électrique Piezozündung
E Câble piezo-électrique Piezoelektrokabel
F Electrode Elektrode
G Thermocouple Thermoelement
H Thermostat de sécuri Sicherheitsthermostat
K Moteur ventilateur Ventilatormotor
L Câble de masse Erdungskabel
M Electrovanne Elektroventil
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Itm ITMG12 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages