Posiflex CD-3x04U_R & CD-3301U Advanced Manual

Type
Advanced Manual
CD-3x04U/R &
CD-3301U
Advanced Manual
Version: A0
REVISION HISTORY
Date
Version
Description
2023/10/17
A0
For preliminary release
i
CONTENTS
REVISION HISTORY ........................................................................................................... 3
CONTENTS ..............................................................................................................................i
CHAPTER 1: FACTORY DEFAULTS ................................................................................. - 15 -
CHAPTER 2: USER DEFAULT SETTINGS ........................................................................ - 15 -
CHAPTER 3: OUTPUT SETTINGS .................................................................................... - 16 -
3.1 USB Interface Settings ............................................................................................... - 16 -
3.2 RS232 Interface Setting ............................................................................................. - 18 -
3.3 Keyboard Language ................................................................................................... - 20 -
3.4 Character Encoding ................................................................................................... - 23 -
3.5 Invoice Scan Mode .................................................................................................... - 26 -
3.6 Invisible Character Output Control Settings .............................................................. - 26 -
3.7 Keyboard Mode Settings ........................................................................................... - 27 -
CHAPTER 4: SYSTEM SETTINGS ..................................................................................... - 30 -
4.1 Enter Setup and Exit Setup ........................................................................................ - 30 -
4.2 Scan Mode ................................................................................................................. - 30 -
4.3 Sleep Settings ............................................................................................................ - 34 -
4.4 Successful Reading Setting ........................................................................................ - 35 -
4.5 Other Sound Settings ................................................................................................. - 38 -
4.6 Image Property Settings ............................................................................................ - 39 -
4.7 Lighting Settings ........................................................................................................ - 42 -
CHAPTER 5: DATA EDITING ........................................................................................... - 44 -
5.1 Prefix/Suffix Setting ................................................................................................... - 44 -
5.2 Prefix Sequence Setting ............................................................................................. - 44 -
ii
5.3 Customized Prefix ...................................................................................................... - 45 -
5.4 Code Type Name Display ........................................................................................... - 46 -
5.5 AIM ID Prefix .............................................................................................................. - 46 -
5.6 CODE ID Prefix ........................................................................................................... - 47 -
5.7 Customized Suffix ...................................................................................................... - 48 -
5.8 Suffix .......................................................................................................................... - 49 -
5.9 Field Interception ...................................................................................................... - 50 -
5.10 GS Character Conversion ......................................................................................... - 51 -
5.11 Character Replacement ........................................................................................... - 53 -
5.12 Set NGR Information ............................................................................................... - 54 -
CHAPTER 6: BARCODE PARAMETER SETTINGS.......................................................... - 56 -
6.1 Overall Settings .......................................................................................................... - 56 -
6.2 Code128/AIM128/EAN128/NL128 ............................................................................ - 57 -
6.3 UPC/EAN/ISSN/ISBN .................................................................................................. - 59 -
6.4 Codabar ..................................................................................................................... - 63 -
6.5 Code 39 ...................................................................................................................... - 66 -
6.6 Code 32 ...................................................................................................................... - 69 -
6.7 Code 93 ...................................................................................................................... - 71 -
6.8 Code 11 ...................................................................................................................... - 74 -
6.9 ITF-25/ITF-14/ITF-6/ Deutsche12/Deutsche14 ......................................................... - 76 -
6.10 Industrial 25 ............................................................................................................. - 78 -
6.11 Matrix 25 ................................................................................................................. - 81 -
6.12 NEC 25 /Japan Matrix 25 ......................................................................................... - 83 -
6.13 Standard 25 ............................................................................................................. - 85 -
6.14 Data Logic 25 ........................................................................................................... - 87 -
6.15 MSI-Plessey .............................................................................................................. - 89 -
6.16 Plessey ..................................................................................................................... - 92 -
6.17 RSS-EXP /RSS_14/GS1 Data ..................................................................................... - 93 -
iii
6.18 Telepen .................................................................................................................... - 95 -
6.19 Pharma Code One-Track .......................................................................................... - 96 -
6.20 PharmaCode Two-Track .......................................................................................... - 98 -
6.21 AZTEC ....................................................................................................................... - 99 -
6.22 CODABLOCK A........................................................................................................ - 101 -
6.23 CODABLOCK F ........................................................................................................ - 103 -
6.24 Data Matrix ............................................................................................................ - 104 -
6.25 MaxiCode ............................................................................................................... - 106 -
6.26 PDF417................................................................................................................... - 108 -
6.27 Micro PDF .............................................................................................................. - 110 -
6.28 QR Code ................................................................................................................. - 111 -
6.29 Micro QR ................................................................................................................ - 113 -
6.30 Han Xin Code ......................................................................................................... - 115 -
6.31 DOTCODE ............................................................................................................... - 117 -
6.32 OCR ........................................................................................................................ - 117 -
CHAPTER 7: BATCH PROCESSING ............................................................................... - 118 -
CHAPTER 8: APPENDIX ................................................................................................. - 120 -
8.1 System Default Setting Table .................................................................................. - 120 -
8.2 Barcode Default Setting Table ................................................................................. - 121 -
8.3 AIM ID List................................................................................................................ - 126 -
8.4 CODE ID List ............................................................................................................. - 128 -
8.5 ASCII code ................................................................................................................ - 129 -
8.6 CTRL+mode output .................................................................................................. - 134 -
8.7 Data code ................................................................................................................. - 135 -
Enter Setup
Exit Setup
- 15 -
CHAPTER 1: FACTORY DEFAULTS
Factory Defaults: The communication mode will be restored to HID-KBW. For other
default values, please refer the System Default Setting Table, “Barcode Default
Setting Table in the Appendix.
Restore All Factory Defaults
$>:S010186.<$
CHAPTER 2: USER DEFAULT SETTINGS
The user can set the required configuration according to the use environment, and
then scan “Save Current Setting to save the current configuration as the user
default configuration. If the user default settings have been set before, this operation
will replace the original user default settings information. The initial user default
configuration can be restored by scanning “Restore User Default Setting”.
Save Current Setting
$>:SVDEF02.<$
Restore User Default Setting
$>:S020286.<$
Enter Setup
Exit Setup
- 16 -
CHAPTER 3: OUTPUT SETTINGS
3.1 USB Interface Settings
When using USB to connect the scanner and host, users can choose USB HID-KBW,
USB virtual serial port or USB HID-POS according to actual needs.
3.1.1 USB HID
USB HID-KBW:
In keyboard mode, place the mouse cursor on the notepad, etc., and the data will be
entered into the notepad after successful decoding.
USB HID POS:
Use HID POS protocol to communicate
USB HID-KBW (Default)
$>:S0F0116.<$
USB HID POS
$>: S0F0516.<$
Upload Data Delay Setting
No Delay (Default)
$>:SC00037.<$
Delay (20ms)
$>:SC04037.<$
Enter Setup
Exit Setup
- 17 -
Delay (40ms)
$>:SC0C037.<$
Delay setting (Any interval)
$>:R0001E2.<$
The data delay is actually delayed according to the character, and the unit is 1ms
(milliseconds).
For Example: Set the delay 10ms (data code is expressed in hexadecimal)
1) Scan code “Enter Setup”
2) Scan code “Delay setting”
3) Scan Data code “0” “A” (in Appendix)
4) Scan code “Save” (in Appendix)
5) Scan code “Exit Setup”
3.1.2 USB Virtual Com
USB Virtual Com:
Enumerate into a virtual serial port. At this time, the PC needs to use the serial port
assistant to receive data.
USB Virtual Com
$>:S0F0216.<$
Enter Setup
Exit Setup
- 18 -
3.2 RS232 Interface Setting
Rs232 interface is a common way to connect scanner and host equipment (such as
PC, POS and other equipment). When using the RS232 interface, the scanner and the
host device must match the communication parameter configuration completely to
ensure smooth communication and correct content.
RS232
$>:S0F0016.<$
3.2.1 Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the baud rate to
match the host requirements.
1200bps
$>:S0F0047.<$
2400bps
$>:S0F0147.<$
4800bps
$>:S0F0247.<$
9600bps (Default)
$>:S0F0347.<$
Enter Setup
Exit Setup
- 19 -
19200bps
$>:S0F0547.<$
38400bps
$>:S0F0647.<$
57600bps
$>:S0F0747.<$
115200bps
$>:S0F0847.<$
3.2.2 Parity
No Parity (Default)
$>:S060046.<$
3.2.3 Stop Bits
1 Stop Bit (Default)
$>:S010046.<$
Enter Setup
Exit Setup
- 20 -
3.2.4 Data Bits
8 Data Bits (Default)
$>:S080846.<$
3.2.5 Flow Control
Non (Default)
$>:S600016.<$
3.3 Keyboard Language
The key arrangement, symbols, etc. of a keyboard is different due to different
national languages. The scanner can be virtualized into keyboard standards of
different countries according your needs, and the default is the US keyboard.
U.S.A (English) (Default)
$>:S1F001D.<$
Belgium
$>:S1F011D.<$
Enter Setup
Exit Setup
- 21 -
Brazil
$>:S1F021D.<$
Canada (French)
$>:S1F031D.<$
Czech slovakia
$>:S1F041D.<$
Denmark
$>:S1F051D.<$
Finland (Swedish)
$>:S1F061D.<$
France
$>:S1F071D.<$
Germany / Austria
$>:S1F081D.<$
Greece
$>:S1F091D.<$
Hungary
$>:S1F0A1D.<$
Israel (Hebrew)
$>:S1F0B1D.<$
Enter Setup
Exit Setup
- 22 -
Italy
$>:S1F0C1D.<$
Latin America
$>:S1F0D1D.<$
Netherlands (Dutch)
$>:S1F0E1D.<$
Norway
$>:S1F0F1D.<$
Poland
$>:S1F101D.<$
Portugal
$>:S1F111D.<$
Romania
$>:S1F121D.<$
Russia
$>:S1F131D.<$
Slovakia
$>:S1F151D.<$
Spain
$>:S1F161D.$
Enter Setup
Exit Setup
- 23 -
Sweden
$>:S1F171D.<$
Switzerland
$>:S1F181D.<$
Turkey_F
$>:S1F191D.<$
Turkey_Q
$>:S1F1A1D.<$
UK
$>:S1F1B1D.<$
Japan
$>:S1F1C1D.<$
Italy 142
$>:S1F1F1D.<$
Thailand
$>:S203F1D.<$
3.4 Character Encoding
Original data transmission: The original decoded data adopts decimal encoding.
Transfer to internal code to send: According to the keyboard language settings of
different countries, the decoded data will be converted into the corresponding
national internal code and sent; please accord with the “keyboard format setting
Enter Setup
Exit Setup
- 24 -
HID-KBW” setting.
Send Original data (Default)
$>:S070019.<$
Convert to internal code to send
$>:S070319.<$
Convert to UNICODE
$>:S070519.<$
3.4.1 Encoding Preset
Example: If the barcodes binary code is SHIFT JIS and the content is Russian, at this
time, turn off the Chinese output first, select RUSSIA in Keyboard Language, and the
HID input code is preset to SHIFT JIS, converted to internal code and sent, it will be
output correctly Russian.
When HID transmission mode-original data transmission, HID input code
preset-invalid! ! !
Auto (Default)
$>:SF0000C.<$
GBK2312
$>:SF0100C.<$
Enter Setup
Exit Setup
- 25 -
UTF-8
$>:SF0200C.<$
BIG-5
$>:SF0300C.<$
SHIFT JIS
$>:SF0400C.<$
3.4.2 Chinese Output Quick Settings
You can set Chinese output to TXT or WORD.
Chinese output to TXT
$>:SHTCT01.<$
Chinese output to WORD
$>:SHTCT02.<$
Disable Chinese output
$>:SHTCT03.<$
Enter Setup
Exit Setup
- 26 -
3.5 Invoice Scan Mode
The QR content format of different invoices is different. After enabling this function,
the decoded result will be analyzed and reorganized according to certain rules. Only
the national tax is supported.
National tax regulations: Start character $+version number
01+base64(name</>taxpayer identification number</>address telephone</>account
opening bank and account number</>CRC)+terminator $.
Disable (Default)
$>:S0F002A.<$
National tax
$>:S01002A.<$
3.6 Invisible Character Output Control Settings
3.6.1 Disable/Enable Invisible Character Output
Enable
$>:S070236.<$
Disable (Default)
$>:S070736.<$
3.6.2 F1-F12 Function Key Settings
Function keys refer to F1-F12. To output “Enter”, need to set “output function keys”.
Enter Setup
Exit Setup
- 27 -
Output function key (Default)
$>:S070036.<$
Output CTRL key combination
$>:S070136.<$
Example: Set the prefix “F8” (Hexadecimal value is 0x1D)
1) Scan code “Enter setup”
2) Scan code “Allow adding custom prefix”
3) Scan code “Set Custom Prefix”
4) Scan Data code: 1” “D” (in Appendix)
5) Scan code “Save” (in Appendix)
6) Scan code “Output CTRL key combination”
7) Scan code “Exit setup”
3.7 Keyboard Mode Settings
3.7.1 Keyboard Input Mode
Standard keyboard input mode
$>:S030037.<$
Virtual keyboard input mode
ALT+NUM
$>:S030337.<$
3.7.2 Analog Numeric Keypad
Analog numeric keypad: Before sending the result of scan code, it will first judge
whether num lock is turned on. If it is not turned on, then send a command to turn it
on.
Enter Setup
Exit Setup
- 28 -
Analog numeric keypad
$>:S040437.<$
NO simulate the numeric keypad
(Default)
$>:S040037.<$
3.7.3 Caps Lock
No Case Conversion
$>:S380037.<$
Letter case interchange
$>:S380837.<$
Convert All to Upper Case
$>:S382037.<$
Convert All to Lower Case
$>:S383037.<$
3.7.4 ALT+NUM Special Settings
When outputting internal code, if use alt+Num model, the first number is 0, the
received input method needs to set the corresponding national keyboard, otherwise
it may be garbled; if the first digit does not add zero, the received system code needs
to be consistent with the internal code output from the scanner, otherwise it may be
garbled. When the keyboard can not output standard ASCII characters, you can
choose to use ALT+number instead of output.
Enter Setup
Exit Setup
- 29 -
Not output the leading 0
$>:S080036.<$
Output leading 0 (Default)
$>:S080836.<$
Keyless ASCII is not output
(Default)
$>:S100036.<$
ALT+Numbers instead of keyless
ASCII
$>:S101036.<$
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128

Posiflex CD-3x04U_R & CD-3301U Advanced Manual

Type
Advanced Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI