Soyal AR-PBI-888 Owner's manual

  • Hello! I've reviewed the user manual for the SOYAL AR-888-PBI Touchless Infrared Button. This document provides details on installation, configuration using dip switches, and wiring diagrams for various access control setups. It also explains how to adjust sensing distance and LED behavior. I'm ready to answer your questions about this device.
  • What are the standard LED ring colors?
    What is the default output mode?
    How do I adjust the sensing distance?
    Can the LED status be adjusted?
    What is the power requirement for the device?
V210908
SOYAL
ACCESS & INDUSTRIAL CONTROL
A.
MPLA-888XA18/19 (US / EU)
CN1
ON
1 2
J2 J1
N.C.
COM
PB
V+
GND
V+
GND
V+
GND
GND
9-24VDC
9-24VDC
N.O.
COM
N.C.
V+
V-
N.O.
COM
N.C.
V-
V+
or
Function Cable Color Description
Relay COM 1 Green DC24V / 1A
N.O. 2 Blue DC24V / 1A
N.C. 3 Purple DC24V / 1A
Power 4 Black DC 0V
5 Red DC 9-24V
Connector:
AR-888-PBI
Touchless Infrared Button
Installation
Connector Table / Dip_switch
AR-888-PBI: Touchless Infrared Button - LED Ring (Standard: Green/Red ; By Order: Blue/Red)
Product (US/EU) Tools Easy Install Kit (By Order)
123
Flat Head Hex Socket
Screw: M3x8
Bottom Cover Allen key
2MM / 48*15MM
Electric Bolt
Controller
Request To Exit
Magnetic Lock
Electric Strike
POWER
POWER
Wiring Diagrams
SW1 SW2 OUTPUT
ON ON Pulse
ON OFF Delay 3 Sec.
OFF ON Latch
OFF OFF Delay 6 Sec.
Standby mode Motion
LED G(Green)LED R(RED)
LED R(RED)LED G(Green)
LED GR
(Green/RED) --
-- LED GR
(Green/RED))
Turn around Sensing distance
Clockwise Sensing distance is greater
Counterclockwise Sensing distance is smaller
LED status adjustment
Dip_switch Output Mode
Sensing distance adjustment
2
3
4
#1 #2
#3 #4
ON
1 2
ON
1 2
ON
1 2
ON
1 2
(Example #2)
1
2
3
4
1
2
3
4
Default Value
Default Value
AR-888-PBI
Sensing distance
adjustment
Connector
Dip_switch
LED status
adjustment
3
4
2
1
J2(LED R)
J1(LED G)
Standby
mode Motion
NC NO
V210908
SOYAL
ACCESS & INDUSTRIAL CONTROL
75
81
84
118
20
15
51
3.3
3.3
24
23
86
88
52
51
13
10
60
18
13
16
12
66
3.3
Proportion 1:1
Unit: mm
US Mounting Hole: 73x48x40mm(HxWxD)
Screw hole pitch : 84mm
Suitable for 70X118 1-module ush-mounting box.
( Australian, Italy, USA(501E) Standard)
EU Mounting Hole: 57x53x40mm(HxWxD)
Screw hole pitch : 60mm
Suitable for 86X86 ush-mounting box.
(UK, Continental Europe, Germany Standard)
Cable selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring.
Use CAT5 for TCP/IP connection.
A.B.C.
D.
2
(Excluded)
By order
5
4
3
3
Pull the cables from the square holes of the eva foam gasket and mounting plate.
Use a screwdriver to screw the mounting plate B onto the wall with Flat Head Cap Philips Tapping Screws (Excluded, the Installer
should prepare before installation.
Connect the cables to the backside of body C and attach C to B at lower position of B. Push C up to make the cogging hooked completely.
Use the Allen key and screws to assemble the body C onto the mounting plate B. Attach the Back Cover D to C.
(Excluded)
In-wall
Depth
28mm
~35mm 1
Installation
/