  • Hello! I am an AI chatbot trained to assist you with the Castell Salvo Traffic Lights User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
49
Issue 1. April 2008
Salvo Traf c Lights
User Guide
Product Description
Product Code: 006538
Salvo TrafÞ c Lights are a means of communicating the
status of the loading bay door.
The lights can be mounted inside, outside or on both sides
of the loading bay.
When mounted inside, a red light indicates that the bay door
cannot be opened. A green light indicates that the door can
be opened and loading or unloading commenced.
When mounted outside, a red light indicates that the
door is open the the vehicle must not drive away. A green
light indicates that the door is closed and the vehicle can
depart.
Installation should be carried out by a qualiÞ ed electrician. Please retain this
document.
Specifi cations
Precautions
Description Specifi cation
Dimensions 180mm (h) x 90mm (w) x 81mm (d)
Termination 2.5mm² in and out
Cable Entries 1 x 5-7mm push through grommet
Mounting Surface
Housing/Lens PC (Flame Retardant)
IP Rating IP65
Temp. Range -20°C - +40°C
Light Source High Output LED
Light Output 12 x LED Array
Voltage 24VDC
Step 01: All units are supplied separate from the back box. The back box must be mounted with
the two cable entries at the top or bottom.
Step 02: 20mm cable entries are provided on all sides and in the base. The back box should be
mounted to a suitable surface or to a standard wiring box, using any of the mounting holes.
Step 03: The supplied gasket should be used if the surface is uneven or if the unit is to be used
in wet conditions.
Step 04: To remove the required knockout, the box should be turned on its face. A 6mm screw
driver blade should be placed in the knockout recess and given a sharp tap. The plastic will break
away cleanly.
Step 05: Connect the power supply to the appropriate terminals (see Salvo Control Panel).
Step 06: Earth continuity of cable sheath or conduit may be maintained by Þ tting earth tags to the
entry Þ ttings and linking them together inside the back box.
Step 07: The installation is completed by Þ tting the beacon onto the back box by means of the
supplied screws.
Step 08: The terminals will accept wires of I4-18AWG. Use the duplicated terminals to route the
in and out wires through the system loop.
Issue 1. April 2008
50
Installation
1
Salvo Traf c Lights
User Guide
Wiring
2
Refer to SCP wiring schematic diagram on page 29.
29
Issue 1. April 2008
Salvo Control Panel (SCP) — User Guide
Wiring Diagram
/