Gigabyte GS-ST590V System Installation Manual

Category
Server barebones
Type
System Installation Manual
System Installation Guide
GS-ST590V
5U RackMount /Tower Server
Dual Intel
®
Pentium Xeon
TM
(Nocona/Iwindale) Processor Serverboard
Rev. 1.0
25A080-05900-F00
2
GS-ST590V Rack Mount Server
Table of Content
Safety, Care and Regulatory Information................................................4
Introduction..............................................................................................8
Contents Packages ................................................................................8
WARNING!...............................................................................................8
Chapter 1 Features Summary.................................................................9
Chapter 2 System Overview................................................................. 11
Chapter 3 System Hardware Installation ...............................................12
Step 3-1: Chassis Removal and Installation ................................................................ 12
Step 3-2: CPU Installation............................................................................................... 13
Step 3-3: Heat Sink Installation....................................................................................... 14
Step 3-4: Memory Installation ........................................................................................ 14
Step 3-5: PCI Expansion Card Installation.................................................................... 15
Step 3-6: Hard Disk Drive Installation ............................................................................ 16
Chapter 4 Appearance of GS-ST590V..................................................17
4-1: Front View of GS-ST590V ...................................................................................... 17
4-2: Rear View of GS-ST590V ...................................................................................... 18
4-3: Switch and LED Indicators Introduction ................................................................. 19
4-4: LAN LED Description............................................................................................... 20
4-5 : Connector Icon Description ................................................................................... 21
Chapter 5 Motherboard Layout & Jumper Setting................................22
5-1: GA-9IVDT Motherboard Layout .............................................................................. 22
5-2: DDR DIMM Slot Population ..................................................................................... 24
5-3: Jumper Setting ......................................................................................................... 25
3
Table of Content
Chapter 6 BIOS Setup ..........................................................................28
Main...........................................................................................................30
Advanced ...................................................................................................33
PCI Configuration............................................................................................................. 34
Advanced Chipset Control ............................................................................................. 36
Advanced Processor Options ........................................................................................ 38
Peripheral Configuration .................................................................................................. 40
Hardware Monitor ............................................................................................................ 43
Security ......................................................................................................47
Server.........................................................................................................49
Console Redirection........................................................................................................ 49
Boot............................................................................................................53
Exit .............................................................................................................54
Chapter 7Driver Installation ...................................................................57
7-1: Intel Chipset Software Installation Utility................................................................ 57
7-2: Broadcom BCM5705/5721 Driver Installation....................................................... 59
7-3: Broadcom LAN Utility Software Installation .......................................................... 61
7-4: Adapetc 8130 Host Raid Driver Installation........................................................... 63
7-5: Adaptec Storage Manager Utility Installation......................................................... 64
7-6: DirectX 9.0C Driver Installation .............................................................................. 66
Chapter 8 Appendix..............................................................................67
8-1: Acronyms................................................................................................................. 67
4
GS-ST590V Rack Mount Server
Safety, Care and Regulatory Information
Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratings and product usage instructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
* Allow the product to cool before removing covers or touching internal components.
Precaution for Product with Laser Devices
Observe the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than
those specified in the product's documentation.
* Only authorized service technicians should repair laser devices.
Precaution for Product with Modems, Telecommunications, ot Local Area
Network Options
Observe the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
5
Safety Information
* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
FCC part 68 (applicable to products fitted with USA modems)
The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with
the FCC.
6
GS-ST590V Rack Mount Server
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunity to maintain uninterrupted telephone service.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux
appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. The Department does not guarantee the equipment will operate to the user satisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
local Telecommunications Company. The equipment must also be installed using an acceptable method
of connection. The customer should be aware that compliance with the above conditions might not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
7
Safety Information
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
CAUTION
Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.
8
GS-ST590V Rack Mount Server
Introduction
Contents Packages
When opening the package, please ensure the system components are not damaged during the shipping.
Using the following checklist to verify the contents. If any component is missing or damaged in the
system, please contact your vendor immediately.
; Chassis ; Power Supply (Installed)
; The GA-9IVDT motherboard ; Silm Type CD-ROM drive (Installed)
; Silm type Floppy drive (Installed)
; Six Hadr Disk Drive Trays
; Two CPU Heat Sinks ; Driver CD for motherboard driver & utility
;
GS-ST590V System Installation Guide ; Tower Kits
Welcome to the Gigabyte GS-ST590V Rack mount / Tower Server System Installation Guide. The
guidebook provides instructions for configuration hardware for the GS-ST590V to your system.
This installation guide will assiste you in installing all the essential components for the sever system.
For your protection, please read and undertand all of the safety and operating instructions regarding your
Gigabyte Server and retain for future reference. The procedures in this guidebook assusme that your are
a system or network administrator experienced in installing similar hardware.
Computer motherboards and expansion cards contain very delicate Integrated Circuit (IC) chips. To
protect them against damage from static electricity, you should follow some precautions whenever you
work on your computer.
1. Unplug your computer when working on the inside.
2. Use a grounded wrist strap before handling computer components. If you do not have
one, touch both of your hands to a safely grounded object or to a metal object, such as
the power supply case.
3. Hold components by the edges and try not touch the IC chips, leads or connectors, or
other components.
4. Place components on a grounded antistatic pad or on the bag that came with the
components whenever the components are separated from the system.
5. Ensure that the ATX power supply is switched off before you plug in or remove the ATX
power connector on the motherboard.
WARNING!
9
Feature Summary
Motherboard GA-9IVDT
Processor Supported Dual socket 604 for Intel
®
Xeon(Nocona/Iwindale)
processor suopprts 3.6 GB and upper
Intel
®
Xeon (Nocona/Irwindale) CPUs supports 800 MHz FSB
L2 cache depend on CPU
Chipset Intel
®
E7320 Chipset
Intel
®
6300ESB
System Memory:
Memory Capacity 6 x 240-pin DDRII DIMM up to 12 GB DRAM (Max)
Memory Type Registered DDRII 400
DIMM Size Support 128MB, 256MB, 512MB, and 1GB memory
Error Correction: Single-bit Errors Correction, Multiple Bit Errors Detection
Expansion Slot 2 PCI-X slot support 64/66MHz (3.3V / The Green slot supports
ZCR)
1 PCI slot supports 32/33MHz (5V)
1 PCI-E slot by x4
SATA controller
Controller Adaptec
®
AIC-8130 supports SATAII 4 ports
Intel
®
6300ESB chipset (without RAID function)
Features Supports Host RAID ( RAID 0,1)
Mirroring supports automatic background rebuilds
Supports RAID 0,1 5 10with ZCR card (2020s)Features LBA and
Extended Interrupt 13 drive translation in controller onboard BIOS
On-Board SATA RAID
Controller Adaptec
®
AIC-8130 supports SATAII interface
Features RAID 0,1,5,10 are supported when ZCR card is populated (Optional)
Cooling Fans: 1 X System Fan
1 X Power Fan
Integrated LANs:
Controller Broadcom
®
BCM 5705 and 5721 LAN Chipset
Integrated Graphics:
Controller ATI Rage-XL
Graphics Memory 8Mb DDR SDRAM
Chapter 1 Features Summary
10
GS-ST590V Rack Mount Server
Mass Storage System 4 x Hot-Swap SATAII HDDs
1 x Standard FDD
1 Standard CD-ROM
Super I/O
Controller ITE IT8712FIX
Built-in I/O 2 x Serial port (1 at front panel)
4 x USB 2.0 dual-port connector (2 at front panel)
1 x VGA connector
2 x RJ45 LAN ports
P/S 2 Keyboard and Mouse Connectors
System BIOS:
BIOS Type Phoenix
®
BIOS, Multi-boot BBS 1.0 Compliant 8Mb Flash Memory
Special Features BIOS HW Monitoring reporting (The values monitored by HW
Monitoring chipset)
Console Redirection via COM ports
Intel
®
Hyper Threading Support
Resume after AC Back
Wake On LAN
ACPI 1.0 Compliant/ ACPI defined S1, S4, and S5
Server Management Functions: (Optional)
BMC Chip NS IPMI 1.5 controller
Failure Detection IPMI 1.5 specification of Server management
Event Logging 32KB Nonvolatile Memory to Log System Failure Events
Remote Management Follow the IPMI 1.5 specification of Server management
Environment
Ambient Temperature Operating Temperature: 5
o
C to 35
o
C
Non-operating Temperature: 0
o
C to 50
o
C
Relative Humidity 10-80% operating Humidity at 30
o
C
Safety Regulations FCC, CE, BSMI, CB, Win2000, 2003 WHQLIPMI 1.5 ( Option)
System Dimention: 8.5” x 17.0” x 19.1”
Electrical Power Supply Single Power Supply 480W
If you are installing Windows
®
XP operating system, please
install Windows
®
XP service pack, otherwise system
may not run properly.
11
System Overview
Chapter 2 System Overview
I
A. Top Chassis Cover H. Blower Cover
B. Side Chassis Cover I. System Fan
C. Motehrboard - GA-9IVDT J. PCI Card Bracket
D. Hard Disk Drive Cage K. Rear Plate
E. ODD Dummy Cover L. FDD Supporter
F. FDD Dummy Cover M. FDD Cage
G. Front Bezel Door
B
A
C
D
E
G
F
H
J
K
L
M
12
GS-ST590V Rack Mount Server
Please observe the safety information in chapter “Important Safety Information”
Do not expose the server to extreme environmental conditions. Protect it from dust,
humidity, and heat.
Step 3-1: Chassis Removal and Installation
Step 1 Unlock the release button from the back of the server.
Step 2 Slide toward to remove the side cover.
Step 3 Reverse Step 1, and 2 to replace the chassis cover.
Chapter 3 System Hardware Installation
Step 1
Step 2
13
GS-ST590V Rack Mount Server
Step 1 Raise the locking bar on the socket.
Step 2 Aligning the pins of the processor with the socket, insert the processor into the socket.
Step 3 Close the handle completely and finish CPU installation.
Step 3-2: CPU Installation
Please make sure the CPU type and speed that are supported by the motherboard.
Step 1
Step 2
Step 3
Pin1 indicator
14
GS-ST590V Rack Mount Server
Step 3-3: Heat Sink Installation
Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Lock the heat sink with the four screws. Installation completed.
Step 3-4: Memory Installation
1. The DIMM slot has a notch, so the DIMM memory module can only fit in one direction.
2. Insert the DIMM memory module vertically into the DIMM slot. Then push it down.
3. Close the plastic clip at both edges of theDIMM slots to lock the DIMM module.
4. DIMM must be populated in order starting at the farthest slot from the MCH chipset.
Each logical DIMM must be made of two identical DIMMs having the same device size on
each and the same DIMM size.
5. Reverse the installation steps when you wish to remove the DIMM module.
For detail DIMM Population, please refer to section 5-2: DDR DIMM Slot Population
Notch
Locked Retaining Clip
15
GS-ST590V Rack Mount Server
Step 3-5: PCI Expansion Card Installation
Step 1 Press the release button to remove the PCI bracket.
Step 2 Push the expansion board into the slot until the board firmly seats.
Repeat Step 1 & 2 to install remaining add-on cards.
Step 3 Reverse step 1 to complete installation.
Step 1
Release button
PCI bracket
Step 2
16
GS-ST590V Rack Mount Server
Step 3-6: Hard Disk Drive Installation
Step 1 Unlock the front bezel door.
Step 2 Open the front bezel by press down the indentation on the front bezel.
Step 3 Press the release button and pull the blank out of the drive bay.
Step 4 Slide hard disk into blank and secure it with screws.
Step 5 To replace the hard drive blank, slide the blank into the bay until it locks into place. Connect cable
and power.
Step 6 Place the hard disk into the server system.
Step 1
Step 2
Release button
Step 3
Step 4
17
GS-ST590V Rack Mount Server
4-1: Front View of GS-ST590V
Chapter 4 Appearance of GS-ST590V
11
1
11
nottuBrewoP
22
2
22
evirDyppolFdradnatS
33
3
33
stroPBSU
44
4
44
troPMOC
55
5
55
sDELtnorF
66
6
66
MOR-DCdradnatS
18
GS-ST590V Rack Mount Server
4-2: Rear View of GS-ST590V
1
droCrewoP
2
hctiwSrewoP
3
esuoM
4
draobyeK
5
stroPBSU
6
troPMOC
7
troPAGV
8
troPNAL54JR
9
troPNAL54JR
19
GS-ST590V Rack Mount Server
4-3: Switch and LED Indicators Introduction
L1
L2
STS
HDD
PWR/SLP
NMI
RST
Name
PWR/SLP
STS
(System)
HDD
L1
Activity
L2
Activity
Color Condition Description
Green On Power On
Green & Amber Blink Sleep (S1)
Amber On Power Off (S4/S5)
Green On System healthy.
Amber On Critical Alarm: Critical Power Module Failure,
Critical FANs Failure, Voltage (Power Supply)
Critical Teemperature and Voltage
Green Blink Hard Disk Drive Access
Green On LAN Link / No access
Green Blink LAN access
-- Off LAN is idle
Green On LAN Link / No access
Green Blink LAN access
-- Off LAN is idle
20
GS-ST590V Rack Mount Server
4-4: LAN LED Description
Color Condition Description
Green ON LAN Link / no Access
Green BLINK LAN Access
Yellow ON 1Gbps connection
Green ON 100Mbps connection
- OFF 10Mbps connection
Name
LAN
Link/Activity
GbE LAN
Speed
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Gigabyte GS-ST590V System Installation Manual

Category
Server barebones
Type
System Installation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI