SICK GRTB18S Operating instructions

Type
Operating instructions

This manual is also suitable for

GRTB18(S)
Operating Instruction
DE/EN/FR/PT/IT/ES/ZH/JA/RU
8019057.16B5
OPERATING INSTRUCTION
Described product
GR18(S)
GRTB18(S)
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is only
permissible within the limits of the legal determination of Copyright Law. Any modifica‐
tion, abridgment or translation of this document is prohibited without the express writ‐
ten permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2006/42/EC
NO
SAFETY
8019057.16B5 | SICK
Subject to change without notice
1
Photoelectric proximity sensor
Operating instructions
1
Safety notes
R
ead t
he operating instructions before commissioning.
Connection, mounting, and setting may only be performed by trained specialists.
Not a safety component in accordance with the EU Machinery Directive.
UL: Only for use in applications in accordance with NFPA 79. These devices shall
be protected by a 1 A fuse suitable for 30 V DC. Adapters listed by UL with connec‐
tion cables are available. Enclosure type 1.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of
the sensor.
2 Correct use
The GRTB18(S) is an opto-electronic photoelectric proximity sensor (referred to as "sen‐
sor" in the f
ollowing) for the optical, non-contact detection of objects, animals, and per‐
sons. If the product is used for any other purpose or modified in any way, any warranty
claim against SICK AG shall become void.
Photoelectric proximity sensor with background suppression.
8019057.16B5 | SICK
Subject to c
hange without notice
1
Dimensional drawing see page 55.
+
Sensitivity
Sensitivity
+
Image: A -2
3 Commissioning
1 Check the application conditions: Adjust the sensing range and distance to the
object or background and the remission capability of the object according to the
corresponding diagram [H] (x = sensing range, y = transition range between the set
sensing range and suppression of the background as a % of the sensing range
(object remission / background remission). Remission: 6% = black , 18% = grey
, 90% = white (referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be determined from
diagram [H] as follows:
Example: x = 40 mm, y = 10% => 10% % of 40 mm = 4 mm. That is, the back‐
ground is suppressed at a distance of > 44mm from the sensor.
6%/90%
18%/90%
90%/90%
25
20
15
10
5
0
mm
(inch)
50
(1.57)
100
(3.94)
150
(5.91)
200
(7.87)
250
(9.84)
300
(11.81)
Distance in mm (inch)
1
2
3
Image: H
2 Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sor
ies).
The maximum permissible tightening torque is listed in Table K.
Note the preferred direction of the object relative to the sensor.
3 The sensors must be connected in a voltage-free state (V
S
= 0 V). The inf
ormation
in the graphics [B] must be observed, depending on the type of connection:
Male connector connection: pin assignment
Cable: core color
2 C
ORRECT USE
2
8019057.16B5 | SICK
Subject to change without notice
+ (L+)
-
(M)
Q
brn
blu
blk
Image: B GRTB18(S)-
x13xx,GR
TB18(S)-
x14xx
+ (L+)
- (M)
Q
brn
blu
blk
1
3
4
Image: B-2 -x23xx
+ (L+)
Q
- (M)
brn
wht
blu
Q
blk
Image: B-3 -x11xx,-
x12xx
+ (L+)
Q
- (M)
brn
wht
blu
blk
1
2
3
Q
4
Image: B-4 -x24xx
Only apply voltage / switch on the power supply (V
S
> 0 V) once all electr
ical con‐
nections have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (graphic B):
Switching outputs Q and /Q (according to graphic B):
GRTB18(S)-P (PNP)
GRTB18(S)-F (PNP)
GRTB18(S)-N (NPN)
GRTB18(S)-E (NPN)
L: light switching
D: dark switching
Q: light switching
Q/: dark switching
Q: dark switching/, object will not be detected
4 Align the sensor with the object. Select the position so that the red emitted light
beam hits t
he center of the object. You must ensure that the optical opening (front
screen) of the sensor is completely clear [E]. We recommend making the adjust‐
ments using an object with a low remission.
Image: E
5
y
x
Image: F
COMMISSIONING 3
8019057.16B5 | SICK
Subject t
o change without notice
3
Sensor with potentiometer:
The sensing rang
e is adjusted with the potentiometer (type: 270°). Clockwise rota‐
tion: sensing range increased; counterclockwise rotation: sensing range reduced.
We recommend placing the switching state in the object, e. g., see graphic F. Once
the sensing range has been adjusted, the object is removed from the path of the
beam, which causes the background to be suppressed and the switching output to
change (see graphic C).
The sensor is adjusted and ready for operation. Refer to graphics C and G to check
the function. If the switching output fails to behave in accordance with graphic C,
check application conditions. See section Fault diagnosis.
Image: C
Image: G
5 Fault diagnosis
Table indicates which measures are to be taken if the sensor stops working.
4
4
8019057.16B5 | SICK
Q
(PNP)
(NPN)
Q
q
1
0
q
1
0
1
0
1
0
Q (PNP)
L
1
0
1
0
1
0
1
0
Q (NPN)
L
Q (PNP)
Q (NPN)
D
D
GRTB18(S)-x24xx
GRTB18(S)-x11xx
GRTB18(S)-x12xx
GRTB18(S)-x23xx
GRTB18(S)-x13xx
GRTB18(S)-x14xx
Subject to change without notice
6 Table Fault diagnosis
LED indicator/fault pattern /
LED indicat
or/fault pattern
Cause /
Cause
Green LED does not light up
No voltage or voltage below
the limit values
Measures /
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Green LED does not light up
Voltage interruptions Ensure there is a stable power
supply without interruptions
Green LED does not light up
Sensor is faulty If the power supply is OK,
replace the sensor
Yellow LED flashes
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
object. / Clean the optical sur‐
faces . / Readjust the sensitiv‐
ity (potentiometer) / Check
sensing range and adjust if
necessary; see graphic F.
Yellow LED lights up, no object
in the path of the beam
Distance between the sen‐
sor and the background is too
short
Reduce the sensing range,
see graphic F
Object is in the path of the
beam, yellow LED does not
light up
Distance between the sensor
and the object is too long or
sensing range is set too
short
Increase the sensing range,
see graphic F
7 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Ef
forts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
TABLE FAULT DIAGNOSIS 6
8019057.16B5 | SICK
Subject t
o change without notice
5
8 Maintenance
SICK sensors are maintenance-free.
We r
ecommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
9 Technical data
GRTB18(S)-
Sensing range 3 ... 300 mm
Sensing range max. 3 ... 300 mm
1)
Light spot diameter/distance 7 mm / 100 mm
Supply voltage V
S
DC 10 ... 30 V
2)
Output current I
max.
100 mA
3)
Max. switching frequency 1,000 Hz
4)
Max. response time < 0.5 ms
5)
Enclosure rating IP 67
Protection class III
Circuit protection A,B,D
6)
Ambient operating temperature -25 °C ... +55 °C
1)
Object with 90 % r
emission (based on standard white DIN 5033)
2)
Limit value: operation in short-circuit protection mains max. 8 A; residual ripple max.
5 Vss
3)
When UV > 24 V and ambient temperature > 49°C IAmax. = 50 mA.
4)
With light / dark ratio 1:1
5)
Signal transit time with resistive load
6)
A = UV-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
8 MAINTENANCE
6
8019057.16B5 | SICK
Subject to change without notice
Dimensional drawing
GRTB18S-X2xx7
GRTB18S-X1xx2
GRTB18S-X1xxZ
GRTB18S-X1xx7
GRTB18S-X2xx7
GRTB18S-X2xxZ
36,1 (1.42)
17,5
(0.69)
2
5
4
1
6
19,2 (0.76)
4 (0.16)
3
M18x1
9,5
(0.37)
1,5
(0.06)
16
3)(0.6
1 x M18
2
6
19,2
(0.76)
4
(0.16)
5
1
9,5
(0.37)
36,1 1.42)(
4
3
38,1 (1.5)
11,5
(0.45)
19,2 (0.76)
Ø 16,7
(0.66)
2 (0.08)
22,6 (0.89)
M12x1
8,2
(0.32)
2,2 (0.09)
Ø 27 (1.06)
M18x1
2
6
7
5
1
4
3
38,1 (1.5)
11,5
(0.45)
17,5
(0.69)
M18x1
2
5
4
1
6
19,2 0.76)(
4
(0.16)
M12x1
3
1,5
0( .06(
16
(0.63)
M18x1
2
6
19,2
(0.76)
4
(0.16)
11,5
(0.45)
38,1 (1.5)
5
1
4
3
M12x1
8,2
(0.32)
2,2 (0.09)
Ø 27 (1.06)
6
7
36,1 1.42)(
9,5
(0.37)
19,2
0.76)(
Ø 16,7
(0.66)
2 0.08)(
22,6 (0.89)
M18x1
2
5
1
4
3
9
8
8019057.16B5 | SICK
Subject to change without notice
55
GRTB18-X1xx2
GRTB18-X1xx7
GRTB18-X2xx2
GRTB18-X2xx7
2.08)(52,9
11,5
(0.45)
54,6 (2.15)
2.89)
73,5
(
2
M18 x 1
6
5
1
4
3
4 (0.16)
2.28)(58
2.81)(71,5
2.15)(54,6
2
Ø 16,7
(0.66)
M18 x 1
9,5
(0.37)
0.08)(
2
6
8,2 0.32)(
1
4
5
3
9,5
(0.37)
52,9 (2.08)
54,6 (2.15)
2
71,5 (2.81)
M18 x 1
5
1
4
3
6
4 (0.16)
2.15)54,6 (
M12 x 1
58 (2.28)
11,5
(0.45)
2.89)(
73,5
0.08)(
2
2
M18 x 1
Ø 16,7
(0.66)
6
8,2 0.32)(
1
4
3
5
1
connection / Anschluss
Threaded sleeve M18 x / Gewindehülse M18 x 1
LED indicator yellow / LED-Anzeige gelb
4 LED indicator green / LED-Anzeige grün
5 Sensitivity control: potentiometer / Empndlichkeitseinsteller: Potentiometer
6 fastening nut, 22 mm hex / Befestigungsmutter 22 mm hex
15
(0.59)
0,6
(0.02)
0,6
(0.02)
25°
M18x1
4,7
(0.19)
9
8
ß
5
7 Mounting ring / Montagering
8 Optical axis, sender / Optikachse, Sender
9 Optical axis, receiver / Optikachse, Empfänger
Standard direction of the material being detected /
Vorzugsrichtung
56
8019057.16B5 | SICK
Subject to change without notice
8019057.16B5 | SICK
Subject to change without notice
57
Table K
Length of thread /
Gewindelänge
mm (inch)
Plastic nut /
Kunststoff mutter
mm (inch)
Metal nut /
Metallmutter
Max. tightening
torque /
Max. Anzugs-
drehmoment
Max. installation
wall thickness /
Max. Einbau-
wandstärke
mm (inch)
= w
Number of M18
nuts /
Anzahl der M18-
Gewindemuttern
short / kurz
GRTB18S-xxxx6 22,6 (0.89) 8,2 (0.32) 0,9 Nm 4,5 (0.18) 2
GRTB18S-xxxx7
GRTB18S-xxxx1 17,5 (0.69) 4 (0.16) 2 Nm 8,1 (0.32)
GRTB18S-xxxx2
GRTB18S-xxxxY 16 (0.63) 11,4 (0.45) 1 + flush ring
GRTB18S-xxxxZ
standard / Standard
GRTB18-xxxx6 58 (2.28) 8,2 (0.32) 0,9 Nm 40,6 (1.6) 2
GRTB18-xxxx7
GRTB18-xxxx1 52,9 (2.08) 4 (0.16) 2 Nm 43,5 (1.71)
GRTB18-xxxx2
W
w = max. installation wall thickness / max. Einbauwandstärke
mm (inch)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

SICK GRTB18S Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI