4
Main display: battery1 voltage, battery state of charge, charging
status.
If arrow is flashing charger is in float.
By arrow of: no solar available.
Press MENU to enter next display.
Main display.
Press the MENU
button for several
seconds until the
display flashes, you are
Battery type setting.
See table below.
The factory setting is b01
key again and you
are in:
Charging Ratio of Battery 1
Current ratio to battery1
20% means 20% of available current
to battery 1 and 80% to Battery2
during Bulk phase.
The factory setting is 50%
Note: In the normal charging status, the controller will divide the charging as the setting.
When battery #1 is fully charged, more charge current will go to battery #2.
When the controller detects that only battery #1 is connected, all the charge current will go
to the battery #1 automatically.
key again and you
are in:
Frequency switching between
Battery1 and Battery2: 25, 50 or
100Hz
The factory setting is 25Hz
voltage
voltage
disconnect
reconnect
b01
12.0V [24V] 14.4V [28.8V] 13.7V [27.4V] 11.2V [22.4V] 12.6V [25.2V]
b02
12.0V [24V] 14.2V [28.4V] 13.7V [27.4V] 11.2V [22.4V] 12.6V [25.2V]
b03
12.0V [24V] 14.6V [29.2V] 13.7V [27.4V] 11.2V [22.4V] 12.6V [25.2V]
b04 LiFePO4 12.8V 14.2V 13.35V 11.2V 12.6V
b05 LiFePO4 25.6V 28.4V 26.7V 22.4V 25.2V