Warning
• Donotinstallthisequipmentinaconfinedspacesuchasabookcaseorsimilarunit.
• WiringmethodsshallbeinaccordancewiththeNationalElectricCode,ANSI/NFPA70.
• ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerference
inwhichcasetheusermayberequiredtotakeadequatemeasures.
• Toreduceariskoffireorelectricshock,donotexposethisproducttorainormoisture.
Caution
• Thisinstallationshouldbemadebyaqualifiedservicepersonandshouldconformtoalllocal
codes.
• Toavoidelectricalshock,donotopenthecabinet.Referservicingtoqualifiedpersonnelonly.
• Theapparatusshallnotbeexposedtowater(drippingorsplashing)andnoobjectsfilledwith
liquids,suchasvases,shallbeplacedontheapparatus.
LGElectronicsherebydeclaresthatthis/theseproduct(s)is/arein
compliancewiththeessentialrequirementsandotherrelevantprovisions
ofDirective2004/108/ECand2011/65/EU.
Contact office for compliance of this product:
LGElectronicsInc.
EURepresentative,Krijgsman1,1186DMAmstelveen,TheNetherlands
• PleasenotethatthisisNOTaCustomerServicecontactpoint.ForCustomerService
Information,seeWarrantyCardorcontactthedealerthatyoupurchasedthisproduct.
Disposal of your old appliance
1. Allelectricalandelectronicproductsshouldbedisposedofseparatelyfrom
themunicipalwastestreamviadesignatedcollectionfacilitiesappointedby
thegovernmentorthelocalauthorities.
2. Thecorrectdisposalofyouroldappliancewillhelppreventpotentialnegative
consequencesfortheenvironmentandhumanhealth.
3. Formoredetailedinformationaboutdisposalofyouroldappliance,please
contactyourcityoffice,wastedisposalserviceortheshopwhereyou
purchasedtheproduct.
Important Safety Instructions
1. Readtheseinstructions.
2. Keeptheseinstructions.
3. Heedallwarnings.
4. Followallinstructions.
5. Donotusethisapparatusnearwater.
6. Cleanonlywithdrycloth.
7. Donotblockanyventilationopenings.Installinaccordancewiththemanufacturer’s
instructions.
8. Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus
(includingamplifiers)thatproduceheat.
9. Donotdefeatthesafetypurposeofthepolarizedorgrounding-typeplug.Apolarizedplug
hastwobladeswithonewiderthantheother.Agroundingtypeplughastwobladesand
athirdgroundingprong.Thewidebladeorthethirdprongareprovidedforyoursafety.If
theprovidedplugdoesnotfitintoyouroutlet,consultanelectricianforreplacementofthe
obsoleteoutlet.
10. Protectthepowercordfrombeingwalkedonorpinchedparticularlyatplugs,convenience
receptacles,andthepointwheretheyexitfromtheapparatus.
11. Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12. Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,or
soldwiththeapparatus.Whenacartisused,usecautionwhenmovingthecart/apparatus
combinationtoavoidinjuryfromtip-over.
13. Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14. Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushas
beendamagedinanyway,suchaspower-supplycordorplugisdamaged,liquidhasbeen
spilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainor
moisture,doesnotoperatenormally,orhasbeendropped.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TOREDUCETHERISKOFELECTRICSHOCK
DONOTREMOVECOVER(ORBACK)
NOUSER-SERVICEABLEPARTSINSIDE
REFERSERVICINGTOQUALIFIEDSERVICEPERSONNEL.
Thislightningflashwitharrowheadsymbolwithinanequilateraltriangleis
intendedtoalerttheusertothepresenceofuninsulateddangerousvoltage
withintheproduct’senclosurethatmaybeofsufficientmagnitudeto
constituteariskofelectricshocktopersons.
Theexclamationpointwithinanequilateraltriangleisintendedtoalertthe
usertothepresenceofimportantoperatingandmaintenance(servicing)
instructionsintheliteratureaccompanyingtheproduct.
FCC WARNING: Thisequipmentmaygenerateoruseradiofrequencyenergy.Changesor
modificationstothisequipmentmaycauseharmfulinterferenceunlessthemodificationsare
expresslyapprovedintheinstructionmanual.Theusercouldlosetheauthoritytooperatethis
equipmentifanunauthorizedchangeormodificationismade.
REGULATORY INFORMATION: FCC Part 15
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,
pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection
againstharmfulinterferencewhentheequipmentisoperatedinacommercialenvironment.
Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalled
andusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradio
communications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhich
casetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
• Asuitableconduitentries,knock-outsorglandsshallbeprovidedinthecableentriesofthis
productintheenduser.
• Caution:Dangerofexplosionifbatteryisincorrectlyreplaced.Replacedonlywiththesameor
equivalenttyperecommendedbythemanufacturer.Disposeofusedbatteriesaccordingto
themanufacturer’sinstructions.
• Holesinmetal,throughwhichinsulatedwirespass,shallhavesmoothwellroundedsurfaces
orshallbeprovidedwithbrushings.
ThisClassAdigitalapparatuscomplieswithCanadianICES-003.
CetappareilnumériquedelaclasseAestconformeàlanormeNMB-003duCanada.
OWNER'S MANUAL
IR Bullet Camera
Please read this manual carefully before operating
your set and retain it for future reference.
MODEL
LCU5500R-BN
LCU5500R-BP
Item LCU5500R-BN LCU5500R-BP
Signal System NTSC PAL
Image Sensor 6 mm (1/3 Type) Super HAD CCD II
Lens 2.8 mm to 11 mm Vari-focal Lens, F1.2
Horizontal
Resolution
Color 650 TV Lines
B/W 700 TV Lines
Day & Night ICR (AUTO / DAY / NIGHT)
Sens-up OFF / AUTO(x2, ... x512)
Minimum
Illumination
(30 IRE)
Color 0. 2 lx @ Sens-up OFF, F1.2
B / W 0 lx @ IR LED ON
S/N Ratio 50 dB
Digital Zoom X16
Sync. System Internal / Line Lock
Video Output 1 Vp-p Composite (75 Ω)
Electronic Shutter 1/60 to 1/120 000 1/50 to 1/120 000
Motion Detection 8 Zones
IR LED IR LED 32 EA, 50 M Distance, SmartIR
Communication RS-485, Coaxial Communication
RS-485 LG, Pelco-D, Pelco-P
Item LCU5500R-BN LCU5500R-BP
Backlight Compensation OFF / WDR / BLC / HSBLC
Privacy Masking 14 Masks
DNR 2D + 3D-DNR
Protection IP66
Power Source DC 12 V / AC 24 V
Power
Consumption
DC 12 V 490 mA
AC 24 V 390 mA
Operating Temperature/
Humidity
-10 ºC to 50 ºC / 0 % RH to 80 % RH
Storage Temperature/
Humidity
-20 ºC to 60 ºC / 0 % RH to 90 % RH
Dimension (W x H x D) 84 mm x 83.5 mm x 320 mm
Weight 1.3 kg
IRBulletcamera SunshieldandFixingscrew
Installationsticker Wrench
M3TappingScrews
Contents
Power Supply
ThiscameramustalwaysbeoperatedDC12VorAC24V.Certified/ListedAdaptorwhichcomply
withLPS.
Handling of the unit
Becarefulnottospillwaterorotherliquidsontheunit.Becautionsnottogetcombustibleor
metallicmaterialinsidethebody.Ifusedwithforeignmatterinside,thecameraisliabletofailorto
getcauseoffireorelectricshock.
• Removedustordirtonthesurfaceofthelenswithablower.
• Useadrysoftclothtocleanthebody.Ifitisverydirty,useaclothdampenedwithasmall
quantityofneutraldetergentthenwipedry.
• Avoidtheuseofvolatilesolventssuchasthinners,alcohol,benzeneandinsecticides.They
maydamagethesurfacefinishand/orimpairtheoperationofthecamera.
Operating and storage location
Avoidviewingaverybrightobject(suchaslightfittings)duringanextendedperiod.Avoid
operatingorstoringtheunitinthefollowinglocations.
• Extremelyhotorcoldplaces(operatingtemperature-10°Cto50°C,however,we
recommendthattheunitbeusedwithinatemperaturerangeof0°Cto45°C)
• Dampordustplace
• Placesexposedtorain
• Placessubjecttostrongvibration
• ClosetogeneratorsofpowerfulelectromagneticradiationsuchasradioorTV
transmitters.
NOTE:
Pleasemakesuretheproductisinstalledappropriateplaceswheresecuredfromflood,suchas
undertheeaves,tooperateproperly.ThisproductiscertifiedasIP66standard.However,ifthere
isanyfloodconcerns,itishighlyrecommendedtouseanoutdoorHousingWhenyouinstallthe
camerainsideanoutdoorHousing,pleaseuseoneofthefollowingmethods:
1. RemovethefrontglassofHousingbeforeinstallingthecamera.
2. TokeepthefrontglassofHousing,removethefrontcover,andthenputthecameracloseto
thefrontglass.
Specification