• If a next command received contains byte data shorter than the Data length, the previous
command is abandoned.
4. TRANSMISSION DATA AFTER COMMAND RECEPTION
When normal data is received, the same data as the reception data is to be transmitted.
Example: 91H, 03H, 00H, 00H, 00H (Reception data)
91H, 03H, 00H, 00H, 00H (Transmission data)
When channel data is received and the data is outside of the range, the data is to be
inverted and transmitted.
Example: 91H, 03H, 00H, 08H, 00H (Reception data)
91H, 03H, 00H, 77H, 00H (Transmission data)
When abnormal data is received, the data is to be inverted and transmitted.
Example: 91H, 03H, 00H, 00H, 6AH (Reception data)
91H, 03H, 00H, 00H, 15H (Transmission data)
When data other than channel data is received and the data is outside of the range, no
data is transmitted.
Example: 91H, 03H, 05H, 00H, 6AH (Reception data)
No response
5. CONTROL COMMAND AND SETTING VALUE
5.1. Channel Fader Gain
5.1.1. Channel Fader Gain - Position setting
Set the input and output channel fader gains to a fixed value position.
Note: Command cannot be received during power off.
9000Series Amplifier responds with the same data as that received.
91H, 03H, <Channel Attribute>, <Channel Number>, <Value>
Page 4 of 24