Dacor Range ER30DSR User manual

Type
User manual

This manual is also suitable for

PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.7
Epicure™ Ranges
ER30D/ER30DSR
1/3
103107
ELECTRIC CIRCUIT REQUIREMENTS
Range Model Circuit Required
Total Connected
Load
ER30D/ER30DSR
240VAC,
60Hz, 30A
5.6kW (23A)
The ratings above are for reference only -
refer to the range rating label
28 5/8” (727mm)
37 7/8”
(962mm)
to
35 3/4”
(908mm)
46 1/16” (1170mm)
27 1/8” (689mm)
26 1/8” (663mm)
24 1/16” (611mm)
23” (584mm)
Rear of Front Panel
to Back of Chassis
MoDEL ER30
SIDE DIMENSIoNS
SELf RIMMING wIth ERv
1 1/16” (27mm)
26 3/8” (670mm)
27 5/16” (694mm)
28 13/16” (732mm)
24 1/4” (616mm)
3” (76mm)
Backguard*
6” (152mm)
Backguard**
** Optional
* Standard
37 7/8”
(962mm)
to
35 3/4”
(908mm)
46 1/4” (1175mm)
9” (229mm)
Backguard**
Finished Side
Panel
MoDEL ER30D
37 7/8”
(962mm)
to
35 3/4”
(908mm)
Rear of Front Panel
to Back of Chassis
28 1/8” (714mm)
45 9/16” (1157mm)
26 5/8” (676mm)
25 5/8” (651mm)
23 9/16” (598mm)
23” (584mm)
MoDEL ER30D
SIDE DIMENSIoNS
wIth StANDARD tRIM
All tolerances: +1/16”, -0 (+1.6mm, -0)
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.8
Epicure™ Ranges
ER30D/ER30DSR
103107
24” Typ.
(610mm)
25” Typ.
(635mm)
F
G
All tolerances: +1/16”, -0 (+1.6mm, -0)
CUT-OUT DIMENSIONS
“F” “G”
36” (914mm)*
30” (762mm)**
30
1
/
16
(916mm)*
* Recommended
** Minimum
2/3
Gas and Electrical Service
The shaded area shown denotes the location of the gas ◊
inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the
location of the existing utilities may be utilized provided they
do not interfere with the sides or rear of the range. Check
local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between ◊
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. ◊
Access to the remote circuit breaker panel/fuse box, when ◊
the range is in place.
The gas supply piping and shut-off valve, and the electrical ◊
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located ◊
so that the range can be pulled out for service while the
appliance remains connected.
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
Non-Combustible
Rear Wall
Combustible Side
Wall Above Range
Countertop
Opening
29 1/4” (743mm)
30 1/16” (764mm)
Cabinet
Opening
23 9/16”
(598mm)
7/16”
(11mm)
10” Min.
(254mm)
Both Sides
1”
(25mm)
Rear Wall
Countertop
Opening
29 1/4” (743mm)
ERV Opening
27 7/8” (708mm)
Minimum Cabinet depth: 27 1/8” (688mm)
Minumum Countertop depth: 28 1/8” (714mm)
30 1/16” (764mm)
Cabinet
Opening
24 1/16”
(611mm)
2 13/16” (71mm)
1”
(25mm)
1/4” Min.
(6mm)
Combustible Side
Wall Above Range
10” Min.
(254mm)
Both Sides
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
wIth ERv RAISED vENt
CAbINEt CUt-oUt DIMENSIoNS
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.9
Epicure™ Ranges
ER30D/ER30DSR
3/3
082007
GAS SUPPLY PRESSURE REQUIREMENTS
Gas Type Manifold Pressure
Minimum Gas
Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Petroleum (LP) 10” Water Column 11Water Column
GAS - ELECTRICAL ACCESS DIMENSIONS
“A” “B” “C”
“D” “E”
4 7/8”
(124mm)
21 3/4”
(552mm)
8 5/8”
(219mm)
10 3/16”
(259mm)
7/8”*
(22mm)
* The hole size can be increased to 1 1/8” by removing the conduit
bracket inside the range electrical access box.
B
E
A
C
D
Gas Inlet
Electrical Connection
Hole in Bottom
Range Electrical Access,
Cover Removed
bACk of RANGE