Wind Crest WER User manual

Type
User manual

This manual is also suitable for

PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:
Save these Instructions for the Local Electrical Inspector's use.
INSTALLER:
Please leave these Installation Instructions with this unit for owner.
OWNER: Please retain these Instructions for future reference
IMPROTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
HOODS SHOULD BR INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD.
SEE TABLE 1 OF THIS INSTRUCTION FOR APPROVED VENTILATORS.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and Electrical
Wiring Must be Be Done By Qualified
Person(s) In Accordance With All
Applicable Codes & Standards.
Including Fire-Rated Construction.
 To Reduce The Risk Of
Fire, Use Only Metal Duct Work.
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent
backdrafting. Follow the heating
equipment manufactures guideline and
safety standard such as those published
by the National Fire Protection
Association (NFPA) and the American
Society for Heating, Refrigeration and
Air Conditioning Engineers
(ASHRAE),
and the local code authorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
D. Before Servicing or Cleaning Unit,
Switch Power off At Service Panel And
Lock Service Disconnecting Means to
Prevent Power From Being Switched On
Accidentally. When The Service
Disconnecting Means Cannot be Locked,
securely Fasten A Prominent Warning
Device, Such As A Tag, To The Service
Panel
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO
DUCT AIR OUTSIDE FOR DUCTED FANS DO NOT VENT EXHAUST AIR INTO SPACE WITHIN
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.
Read this instruction completely before starting installation. Planning the complete installation before starting any work is
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,
and adequacy of mounting surfaces.
DUCTING: Use a minimum 8" round duct for VEN030I, VEN060I and VEN060E installations. Use a minimum 10" round
duct for VEN120E, VEN100E, VEN140E and VEN060I-Dual installations. Use #10100 8" - round transition or #10287 10"-
round transition from hood to ducting. Other Transition options are available See your Dealer for details.
INSTALLATION INSTRUCTIONS
HOOD MODELS WSL, WCL, & WER
TABLE - 1
Use model VEN030I or VEN060I
for internal ventilator. Use
VEN060E, VEN120E, VEN100E
or VEN140E for remote ventilator
This hood has been designed to be used with the ventilators shown in Table-1.
Before cutting into cabinets, it is necessary to confirm that the correct ventilator
is being used. Your dealer should have reviewed your needs prior to your
purchase. Be sure you have the correct ventilation system.
CAUTION: To Reduce The Risk Of Fire And Electrical Shock, Install This
Rangehood Only With Blowers Manufactured By Wind Crest.
By CNP INDUSTRIES, INC.
P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721
.
NOTE: Unit must be vented
to outside of the building.
Prepare cabinet for mounting the hood per FIG-2. Use
furring strips to level cabinet mounting surface with any
cabinet trims. If your hoods accepts and your using dual
internal ventilators refer to that instruction section.
Attach and secure the transition to the hood with #6x3/8
sheet metal screws and tape all joints prior to installing the
hood. Attach hood to cabinet using #10 wood screws.
Holes are located in the back panel and top panel of the
hood for mounting. Use a minimum of four #10x3/4 wood
screws to mount the hood. Longer screws are required if
wall board or other nonstructural surfaces are used
between the hood and main mounting surface which

holes for additional mounting use appropriate anchors if
not engaging the wood structure.
HINT: If you find vibration noise is present because of
cabinet structure use additional screws, in holes available,
to rigidize mounting.
Connect 120 volt, 60 Hz power through the conduit hole
in top of hood, connecting to pigtail in hood junction box,
white to white, black to black and connect green ground
wire to the power supply ground wire per local codes.
The recommended height from countertop or cooking
surface to the bottom edge of the hood is 30 to 36 inches.
Hood is recommended for use over domestic gas or
electric appliances. Not recommended for use over solid
fuel fired appliances.
After installing the hood, install the internal blower
(see FIG-1) unit by positioning the blower onto
bracket-A, notched blower bracket will center
blower. Rotate into position against hood top and
secure with #8 sheet metal screws via bracket-B. To
ease assembly you should predrive and then remove
the #8 screws before installing the blower. If the
remote ventilator is used see related instructions. The
VEN100E/140E ventilator will require revision of
some wiring in the hood receptacle box and possible
modification of air discharge opening See
VEN100E/140E instructions.
NOTE: VEN140E requires a 20 AMP Power Supply.
CAUTION: The hood is of sufficient weight that two
installers are recommended to prevent injury or damage to
the hood in handling.
Turn the power on at the service entrance and check the
operation of the controls.
NOTE: be sure that all dampers are operating properly and
are free to open.
BACKDRAFT DAMPER
: It is recommended that a backdraft damper be used
in all installations. In cold weather installations it is necessary to use a backdraft
damper to minimize backflow of cold air into room. A non-metallic thermal
break should also be used to minimize conduction of outside temperatures
through the ductwork. The thermal break should be located as close as possible
to where the ducting enters the heated portion of the house.
SAFTY WARNING:
Turn off power circuit at
the service entrance and
lockout panel before
wiring the range hood.
A
B
FIG-1
ROTATE
INTO
POSITION
WIRING ACCESS
SINGLE VENTILATOR - INTERNAL OR REMOTE
ADD FURRING STRIPS TO PROVIDE AN EVEN
BOTTOM SURFACE FOR THE HOOD MOUNTING.
BOTTOM VIEW OF CABINET - FOR MODELS WSL & WCL 30" - 48"
HOOD WIDTH
2
3
4
60"
48"/54"
42"
WIRING ACCESS
5
23 1/8
17 1/2
11 1/4
8 3/8
DIM A
"A"
C
L
7
1
8
4
7
3
1
8
5
2
2
1
FIG-2
BACK WALL
1
10
2
4
1
4
12
18"
24"/27"
ALL HOODS
2"
12"
8" OR 10" DUCT
TO DISCHARGE
W/ROOF OR WALL CAP
TRANSITION #10100 OR #10287
FIG - 4
THE 8" DISCHARGE WITH THE TRANSITION # 10100,
WILL BE ON THE CENTER LINE OF HOOD WIDTH
AND ON CENTER LINE OF 12" DIMENSION
OR 10" DISCHARGE WITH TRANSITION # 10287
WER MODELS
WSL & WCL MODELS
30"/36"
REMOVE COVER PLATE
2
BOTTOM SURFACE FOR THE HOOD MOUNTING.
ADD FURRING STRIPS TO PROVIDE AN EVEN
2
BACK WALL
12
4
1
4
1
10
3
4
L
7
1
8
C
1
7
8
5
BOTTOM VIEW OF CABINET - FOR MODELS WER36" - 48"
WIRING ACCESS
1
2
FIG-3
1
2
3
44
3
2
1
LIGHT
LEFT
RIGHT
LIGHT
12 B # 1
18 B # 6
18 R # 22
18 BL #23
18 B # 24
18 W # 9
18 B # 8
18 W # 10
18 B # 7
18 W
18 B
18 BL
18 R
18 W # 5
18 W # 25
18 B # 12
18 W # 13
18 G # 11
18 BL # 3
18 B # 2
18 R # 4
BLOWER
MOTOR
ROTARY
3-SPD
SWITCH
BOX
RECEPTACLE
RECEPTACLE
PLUG
POWER SUPPLY
N G L1
WIRING DIAGRAM-INTERNAL BLOWER & LIGHTING
A
B
1
2
3
SWITCH
LIGHT
I
I
I
I
I
I
1 2 3
4 5 6
18 W # 5
1
22
1
1
2
3
44
3
2
1
RIGHT
HEAT
LIGHT
HEAT
LIGHT
LEFT
LIGHT
LEFT
RIGHT
LIGHT
12 B # 1
18 R # 22
18 BL #23
18 B # 24
18 B # 14 18 B # 15
18 W # 21
18 B # 16
18 B # 18
18 B # 19
18 B # 17
18 W # 20
18 W # 10
18 W
18 B
18 BL
18 R
18 W # 25
18 B # 12
18 W # 13
18 G # 11
18 BL # 3
18 B # 2
18 R # 4
BLOWER
MOTOR
18 W # 26
HEAT
LIGHT
SWITCH
LEFT
SWITCH
HEAT
LIGHT
RIGHT
BOX
RECEPTACLE
RECEPTACLE
PLUG
POWER SUPPLY
N G L1
WIRING DIAGRAM-INTERNAL BLOWER, LIGHTING & HEAT LAMPS
18 W # 5
SWITCH
18 W # 5
I
I
1
LIGHT
4
32
I
65
I
I
I
18 B # 6
B
A
18 B # 8
SWITCH
3-SPD
ROTARY
2
3
1
18 W # 9
18 B # 7
Dual Internal Ventilators
NOTE: Wiring harness #10220 is required to complete the installation
of dual VEN060I ventilators and must be ordered separately.
Cabinet Mounting
When using two (2) VEN060I ventilators the cabinet mounting must accommodate two discharge transitions. Wiring
and discharge holes are shown in FIG 6.
HINT: Transition dimensions may very. Before assembling transitions to hood, fit them into the prepared cabinet
opening to be sure the openings are large enough to accommodate the transition. Enlarge the hole if required
Hood Preparation
The hood must be prepared for dual ventilat
discharge hole plates. To remove, break the metal webs holding the plate and remove completely. See FIG 5. Break the
metal webs by placing a screwdriver at one corner of the plate and hitting screwdriver sharply with a hammer. After breaking
a second web the plate can be flexed to break other webs
.
Wear eye protection when using tools.
Attach the transition (See DUCTING, pg 1), obtained separately from your local hardware or available through your dealer,
and install the hood as described previously in this instruction.
Ventilator Installation
Install the ventilators as previously described, see FIG 1 and instruction on same page of this document. Connect the
ventilators to the receptacle in the hood junction box using Harness #10220, ordered separately. Dress the wires and
 5, using the wire tie supplied with the harness. Follow the remaining instructions for
operating checks to complete the installation.
FIG - 5
HOOD BACK
"A"
TIE
AIR DISCHARGE
HOOD TOP
KNOCKOUTSKNOCKOUTS
AIR DISCHARGE
18"
24"/27"
ALL HOODS
2"
12"
10"
TO DISCHARGE
W/ROOF OF WALL CAP
TRANSITION #10100
FIG - 8
THE 8" DISCHARGE WITH THE TRANSITION # 10100
- TO Y-ADAPTER/10" DISCHARGE
BOTTOM VIEW OF CABINET - FOR MODELS WSL, WCL 48, 54 & 60
FIG-6
HOOD WIDTH
DIM A
48" & 54"
8 1/8
ADD FURRING STRIPS TO PROVIDE AN EVEN
BOTTOM SURFACE FOR THE HOOD MOUNTING.
13 3/4
60"
DUAL INTERNAL VENTILATORS
BACK WALL
4
3
WIRING ACCESS
18 R # 22
18 BL #23
18 B # 24
18 W # 25
18 B # 12
18 W # 13
18 G # 11
BOX
RECEPTACLE
RECEPTACLE
PLUG
POWER SUPPLY
N
G
L1
WIRING - DUAL INTERNAL BLOWERS
BLOWER
MOTOR
BLOWER
MOTOR
1
1
2
2
3
3
4
4
2
4
3
1
2
4
3
1
WIRE HARNESS # 10220
HOOD CONTROL PANEL
SEE WIRING DIAGRAM FOR DETAILS.
RECEPTACLE BOX WIRING SHOWN IS
FOR MODELS WITH HEAT LAMP.
FIG-7
2
4
1
5
5
5
12
8
3
7
5
"A"
7
3
8
3
7
8
7
3
8
3
4
4
1
10
8
3
9
8
9
3
1
1
2
2
3
3
4
4
18 BL
18 R
18 B
18 W
WILL BE ON A LINE 9-3/8 TO THE LEFT
& RIGHT OF THE HOOD CENTER LINE
& ON CENTER LINE OF 12" DIMENSION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Wind Crest WER User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI