LMI 49146 Owner's manual

Type
Owner's manual

This manual is also suitable for

LIQUIPRO
®
3-Function Valve
For 300/400 Series Cartridge
Valve Type Liquid Ends
Information Sheet
Manual No : 2001
Rev. : B
Rev. Date : 11/2015
sales@novatech-usa.com
www.novatech-usa.com
Tel: (866) 433-6682 Fax: (866) 433-6684
Tel: (281) 359-8538 Fax: (281) 359-0084
1 Instruction Sheet
LIQUIPRO
®
3-FUNCTION VALVE
Priming
Priming the pump can be accomplished by a simple
1/4 turn of the Relief Knob. Prime your LMI
®
pump
while it is connected to a pressurized line.
Pressure Relief
Provides protection against excessive system
pressure.
Line Depressurization
By opening the Relief Valve, the discharge line
will depressurize without having to loosen or
disconnect discharge tubing.
Model Numbers
Note:
Part numbers are for 300/400 Series LIQUIPRO
®
cartridge valve type Liquid Ends only.
Valves supplied with a pump include connections
as specied by pump model number. All valves
sold as separate accessories are supplied with 1/2”
NPT connection. For tubing connection, order one
of the following kits:
Connection Kits
Valve
Number
Wetted Materials
Body Diaphragm “O” Ring
49146 PVDF
FLUOROFILM™
POLYPREL™
49147 PVDF PTFE
49148 PVC
POLYPREL™
Kit # LMI
®
Tubing Size Contents
77378 3 x 6 mm 1 Knob, 1 Ferrule
77379 6 x 8 mm 1 Knob, 1 Ferrule
77380 9 x 12 mm Insert, 1 Sleeve
77382 1/4” 1 Knob, 1 Ferrule
77383 3/8” 1 Knob, 1 Ferrule
77384 1/2” Insert, 1 Sleeve
Pressure Relief
Return Tubing
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
2Instruction Sheet 2
LIQUIPRO
®
3-FUNCTION VALVE
METHOD OF OPERATION
A. Priming
1. Connect return tubing to (relief) port.
2. Route tubing to solution tank. Be sure the end
of tubing is above the maximum solution level
(Do not submerge tubing in solution).
3. Turn Relief Knob 1/4 turn to open.
4. Set pump at 100% speed and 100% stroke. Start
pump. When solution begins to ow through
translucent return tubing, the pump is primed.
5. Stop pump. Turn Relief Knob 1/4 turn to
close.
Note:
(a) Pump is normally self-priming if suction lift
is no more than 5 ft (1.5 m), valves in the pump
are wet with water (pump is shipped from factory
with water in pump head) and the above steps
(A1 through A4) are followed.
(b) If the pump does not self-prime, remove
3-function valve and Discharge Cartridge Valve,
and pour water or solution slowly into discharge
port until it is lled. Replace Cartridge Valve, and
follow steps A1 through A4 thereafter.
B. Depressurizing Discharge Line
1. It is possible to depressurize discharge line
and pump head without removal of tubing or
loosening of ttings. Be sure injection check
valve is properly installed and is operating.
If a gate valve or globe has been installed
downstream of the injection check valve, it
should be closed. Be certain return tubing is
connected and run to solution supply tank.
2. Turn Relief Knob 1/4 turn to open.
Turn Pressure Relief Knob
90° counterclockwise to
prime pump
3. Solution should exit the return tubing. The
discharge line is now depressurized.
4. If injection check valve is of higher elevation than
pump head, disconnecting tubing at injection
check valve end will allow air to enter and cause
solution to drain back to tank.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
LMI
®
is a registered trademark of Milton Roy, LLC.
LIQUIPRO
®
is a registered trademark of Milton Roy, LLC.
FLUOROFILM™ is a trademark of Milton Roy, LLC.
POLYPREL™ is a trademark of Milton Roy, LLC.
© 2015, 2009 Milton Roy, LLC.
www.lmipumps.com
We are a proud member of Accudyne Industries, a leading
global provider of precision-engineered, process-critical,
and technologically advanced ow control systems and
industrial compressors. Delivering consistently high levels
of performance, we enable customers in the most important
industries and harshest environments around the world
to accomplish their missions.
sales@novatech-usa.com
www.novatech-usa.com
Tel: (866) 433-6682 Fax: (866) 433-6684
Tel: (281) 359-8538 Fax: (281) 359-0084
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

LMI 49146 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI