Chamberlain LiftMaster CB124EV Installation guide

Type
Installation guide

Chamberlain LiftMaster CB124EV is a simplified setup device that allows you to control your gate motors and safety photocells. With its easy-to-follow instructions, you can ensure that your motors are operating in the right direction, program the motors' travel distances and safety circuits, and program radio transmitters. Additionally, you can set automatic closure and integrate your device with the Chamberlain My Q Starter Kit for remote access and control. The CB124EV is a versatile and user-friendly device that provides enhanced security and convenience for your gate system.

Chamberlain LiftMaster CB124EV is a simplified setup device that allows you to control your gate motors and safety photocells. With its easy-to-follow instructions, you can ensure that your motors are operating in the right direction, program the motors' travel distances and safety circuits, and program radio transmitters. Additionally, you can set automatic closure and integrate your device with the Chamberlain My Q Starter Kit for remote access and control. The CB124EV is a versatile and user-friendly device that provides enhanced security and convenience for your gate system.

LiftMaster CB124EV Simplified Set Up With My Q Starter
Device
Step 1 Ensure all the connections for the motors and safety photocells are wired correctly as per the
diagram below.
Step 2 Check the Dip Switch Settings are correct.
1. All Dipswitch settings should be set to off unless only one motor is being used. If only one
motor is used, set dip switch 4 to on.
Step 3 Testing the polarity of the motors to ensure they are operating in the right direction.
1. Press and hold P1, P2 & P3 simultaneously for 2-3 seconds until the Learn LED begins to flash
yellow and release.
2. Press P1 until motor 1 begins to move in the opening direction. If motor 1 closes first the
polarity needs to be changed by swapping the red & blue cable of motor 1.
3. Press P2 until motor 2 begins to move in the opening direction. If motor 2 closes first the
polarity needs to be changed by swapping the red & blue cable of motor 2.
4. Once the motors are operating in the right direction, move the gates to the close position
manually.
Step 4 Programming the motors travel distances and safety circuits. Please note once the travel is
complete the safety circuits already wired in will be detected.
1. Press P1 until motor 1 begins to open and release.
Motor 1 will reach the open position and stop.
Motor 2 will then start to open and stop in the open position.
Motor 2 will then move to the close position and stop.
Motor 1 will then move to the close position and stop.
Wait for the Learn LED to turn off.
Programming complete.
Step 5 Programming Radio Transmitters.
1. Turn the Radio dip switch on.
2. Press the P1 button once and release.
3. Press and hold the desired button on the remote until you see the CH1 button flash 5
times and release.
4. Turn Radio dip switch off.
5. Programming complete.
Step 6 Setting automatic closure (If required). This is only possible if photocells are connected into
Com & Photo 1.
1. Press & hold P2 until the yellow LED starts flashing.
2. Now count how long you want the gates to automatically close after.
3. Press P2 again.
4. Programming complete.
Please note.
If the DGN LED is still flashing after this basic setup, this will refer to an error within your installation.
See the table of diagnostics on the page below. Correct the issue and restart the programming
sequence from the beginning.
After all diagnostic issues are resolved, please move to the next page if you require installing &
programming the My Q gateway kit.
Step 7 - Programming the Chamberlain My Q Starter Kit. This is only possible if photocells are connected
into Com & Photo 1.
1. Plug the My Q Gateway into your WIFI Router, Connect power to the My Q Gateway.
2. On your Smart phone, download the LiftMaster My Q application from your app store.
3. Create an account for the application.
4. Stand next to your gate whilst completing the following steps.
Press the + sign.
Select add new place.
Enter the serial number found
on the back of the gateway
module.
Give your place a name. I.E.
Building Name.
Select add new device.
Locate the reset button on
your CB124EV control board
but do not press it yet!
Trigger the gate to open via a
programmed remote. Once
the gate begins opening press
the reset button three times.
You will hear a tone for each
press.
Reset button shown in the
picture above.
After Success of
programming the device, it
will require naming. I.E. Front
Gate. All Programming
Complete.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Chamberlain LiftMaster CB124EV Installation guide

Type
Installation guide

Chamberlain LiftMaster CB124EV is a simplified setup device that allows you to control your gate motors and safety photocells. With its easy-to-follow instructions, you can ensure that your motors are operating in the right direction, program the motors' travel distances and safety circuits, and program radio transmitters. Additionally, you can set automatic closure and integrate your device with the Chamberlain My Q Starter Kit for remote access and control. The CB124EV is a versatile and user-friendly device that provides enhanced security and convenience for your gate system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI