  • Hello! I am an AI chatbot trained to assist you with the GE ISOVOLT Titan E Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the maximum tube voltage of the GE ISOVOLT Titan E?
    What is the maximum anode dissipation?
    What is the large focal spot size?
    What is the small focal spot size?
    What is the inherent filtration?
    What is the cooling oil flow rate?
    What is the maximum cooling oil temperature?
    What is the maximum cooling oil pressure?
ISOVOLT X-ray Tubehousing
ISOVOLT 420M1/25-55
Application
Radiographic and radioscopic inspections of welds and castings.
Radiometric and dosimetry applications.
Features
Direct radiating tube with double focus, bipolar, oil-cooled anode,
axial high voltage connections with maintenance-free radial HV plugs
Metal-ceramic tube with oblique anode and Beryllium window
Compatible with X-ray equipment of the ISOVOLT series
• ProducedunderISO9001certiedqualitymanagementsystem
Options
Centering and collimator attachment with laser centering device
Tube yokes
GE
Measurement & Control
©2012GeneralElectricCompany.AllRightsReserved.Specicationsaresubjecttochangewithoutnotice.GEisaregisteredtrademarkofGeneralElectricCompany.Othercompanyorproductnames
mentionedinthisdocumentmaybetrademarksorregisteredtrademarksoftheirrespectivecompanies,whicharenotaliatedwithGE.
Contact: GE Sensing & Inspection Technologies GmbH, Bogenstrasse 41, 22926 Ahrensburg, Germany, T +49 (0)4102 807 0
GEIT-30191EN (07/12)
www.gesensinginspection.com
Large focal spot Small focal spot
Maximum tube voltage 420 kV
Maximum anode dissipation 4500 W 1500 W
Tube current at max. tube voltage 10.7 mA 3.5 mA
Focal spot size (EN 12 543) 5.5 mm (~3.0 IEC 336) 2.5 mm (~1.2 IEC 336)
Emergent beam angle 40°
Inherent filtration 7 mm Be + 2 mm Al (removable)
High voltage connection 2 disk connections for 225 kV
Cooling oil flow rate min. 17 l/min
Cooling oil temperature max. 50° C (inlet)
Cooling oil pressure max. 9 bar
Weight (with optional cable quick-lock) 90 kg (198 lbs)
Dimensions see drawing
Technical Data
The generation of radiation in an X-ray
tube solely depends on the operation
values, not on the make. The dose rate
relevant in practice and suitable for
calculations of radiation protection
valuesisdenedbynationalstandards;
Dose Rate within the Central Beam
thus the dose rate of the tubehousing
ISOVOLT 420M1/25-55, measured at
a distance of 1 m from the focal spot,
amounts to 37 Sv/h at maximum tube
voltage and maximum anode dissipa-
tion.
This value must not be used to assess
biologicaleects.
The dose rate of the leakage radiation is
< 10 mSv/h.
40°
292 (11.5")
180 (7.1")
577 (22.7")
798 (31.4")
Ø 362 (14.3)
10 15 706520 25 30 35 40 45 50 55 60 959075 80 85 110105100
D7
Belichtungsdiagramm
FFA = 900 mm D7Pb S = 2,0
Exposure Diagram
FFD = 900 mm D7Pb D = 2.0
mA x min
mm Fe
450 kV
420 kV
400 kV
380 kV
360 kV
340 kV
320 kV
300 kV
280 kV
260 kV
240 kV
220 kV
10
20
50
100
200
1
2
5
/