  • Hello! I've reviewed the mounting and operating instructions for the Sentera AWP-10-13-13 All-Weather Protective Hood. This document provides guidance on how to mount the hood, which is designed to protect outdoor sensors from weather and sunlight. I am ready to answer your questions about the device.
  • What is the purpose of the AWP?
    What materials are used to make AWP?
    What standards does the AWP comply with?
AWP ALL-WEATHER PROTECTIVE
HOOD
Mounting and operating instructions
www.sentera.eu
MIW-AWP-EN-000 - 13 / 05 / 2022 2 - 5
back to the table of contents
AWP ALL-WEATHER PROTECTIVE
HOOD
Table of contents
PRODUCT DESCRIPTION 3
ARTICLE CODE 3
INTENDED AREA OF USE 3
CONTENTS IN THE BOX 3
STANDARDS 3
MOUNTING INSTRUCTIONS IN STEPS 4
TRANSPORT AND STORAGE 5
WARRANTY AND RESTRICTIONS 5
www.sentera.eu
MIW-AWP-EN-000 - 13 / 05 / 2022 3 - 5
back to the table of contents
AWP ALL-WEATHER PROTECTIVE
HOOD
PRODUCT DESCRIPTION
AWP is an all-weather protective hood for outdoor sensors that protects them
against variable weather factors and direct sunlight. It aims to increase the service
life of HVAC outdoor sensors and increase the reliability of their measurements.
ARTICLE CODE
Article codes
Code Width [mm](assembled) Depth [mm](assembled) Height [mm](assembled)
AWP-10-13-13 103 127 128
INTENDED AREA OF USE
Protects Sentera outdoor sensors against direct sunlight and variable weather
conditions.
For outside use.
CONTENTS IN THE BOX
Contents in the box
Element Pcs. Material Dimensions
SNAP-Rivet 7Polyamide, light grey
Sheet 4 Polypropylene, white
Sheet (back) 1 Polypropylene, white
STANDARDS
Coneg norm (USA) & Directive 94/62/EC
RoHS Directive 2002/95/EC (European Parliament and the Council of 27 January
2003)
www.sentera.eu
MIW-AWP-EN-000 - 13 / 05 / 2022 4 - 5
back to the table of contents
AWP ALL-WEATHER PROTECTIVE
HOOD
MOUNTING INSTRUCTIONS IN STEPS
1. Fix Part 1 to the wall together with the product.
2. Snap/connect part 2 to part 1 using part 5 (snap rivet).
3. Snap/assemble both parts 3 to part 4 and after that to part 2 using a snap rivet.
4. Snap/assemble fixed parts 3 and 4 to part 1 and 2 on the left side using a snap
rivet.
5. Snap all the free ends of the parts to part 1 and 2 on both sides using a snap
rivet.
Fig. 1 Mounting steps
Parts Step 1
Part 5
Part 1
Part 2
Part 3
Part 3
Part 4
Part 1
Step 2 Step 3
Part 2
Part 1
Part 3
Part 2
Part 3
Part 4
Part 1
Step 4 Step 5
www.sentera.eu
MIW-AWP-EN-000 - 13 / 05 / 2022 5 - 5
back to the table of contents
AWP ALL-WEATHER PROTECTIVE
HOOD
Fig. 2 Mounting dimensions - flush mounting
120 mm
127 mm
124 mm
130 mm
78 mm
64 mm
2 x Ø4 mm
4 x Ø5,5 mm
TRANSPORT AND STORAGE
Store in its original packaging in a dry and ventilated place, at a temperature around
20°C, away from light.
WARRANTY AND RESTRICTIONS
is warranty runs for two years from the delivery date for manufacturing defect.
Any modification or alteration to the product releases the manufacturer from all
responsibility. e manufacturer bears no responsibility for any misprint or mistake
in this data, modification or improvement to the product can be made at any time
after date of publication.
/