Installation
332291U 13
Choose an Installation Location
• Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
• Refer to the mounting hole layouts provided in
the Mounting Pattern section of this manual,
page 38. No other installation configuration
should be used.
• Use designated mounting holes and provided
configurations only.
• Always mount the G3 oil models upright.
• Mount top fill G3 pump models so that there is
a a minimum clearance of four inches (4.0 in.)
(10.2 cm) above the reservoir to allow for lid
removal and filling.
• If the G3 grease model is going to be operated
in a tilted or inverted position for any period of
time, you must use a model that includes a fol-
lower plate, otherwise the G3 must be mounted
upright. Refer to your model number to confirm
if a follower plate was installed on your pump.
See page 5, Understanding the Model Num-
ber to identify this character in your model
number.
• Use the three fasteners (included) to secure the
G3 to the mounting surface.
• Some installations may require an additional
reservoir support bracket. See table below for
bracket information.
• In high vibration environments, additional isola-
tion at mounting point is necessary. See table
below.
• AC pumps are not recommended when high
vibration or shock is present.
System Configuration and
Wiring
Grounding
If the product is permanently connected, it must be:
• installed by a qualified electrician or serviceman.
• connected to a grounded, permanent wiring sys-
tem.
If an attachment plug is required in the end use
application:
• it must be rated for the product electrical specifica-
tions.
• it must be an approved, 3-wire grounding type
attachment plug.
• it must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
• when repair or replacement of the power cord or
plug is required, do not connect the grounding wire
to either flat blade terminal.
AUTOMATIC SYSTEM ACTIVATION HAZARD
The system is equipped with an automatic timer that
activates the pump lubrication system when power
is connected or when exiting the programming func-
tion. Unexpected activation of the system could
result in serious injury, including skin injection and
amputation.
Before you install or remove the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
Part No Description
571159 Reservoir bracket and strap
125910 L-Bracket for pump
127665 USP to G-Series mounting
bracket
132187 Isolator mounting kit
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Improper installation of the grounding conductor may
result in a risk of electric shock. This product must be
installed by a qualified electrician in compliance with
all state and local codes and regulations.