S G C □ - □ □ □ □ - □ - □
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
0: 100 to 240 V AC, 1: 24 V AC/DC
*2
Output 2
*1
Output
*2
, Output 1
*1
Input
Series name
SGC: 1-output, SGCW: 2-outputs
SGCL: 1-output + Serial communication
*1: For SGCW only
*2: For SGC, SGCL only
or detailed input/output spec, refer to the full Instruction Manual.
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
key
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
key
key
key
key
key
key
Custom display
mode 2
key
key
key
key
key
key
MODE
key
for 5 sec
MODE
key
Input
setting mode
Output 1
setting mode
Output 2
setting mode
Instrument
setting mode
Communication
setting mode
display
setting mode
Manual mode
key for
3 sec
key
for 3 sec
Input type
key
Decimal
point place
key
Output 0%
value
key
Output
100% value
key
Indication
unit
key
Save
settings
key
Output 1
type
decimal
point place
value at
output 0%
value at
output 100%
Output 1
low limit
Output 1
high limit
Output 1
Normal/Reverse
Save
settings
Output 2
type
decimal
point place
value at
output 0%
value at
output 100%
Output 2
low limit
Output 2
high limit
Output 2
Normal/Reverse
Save
settings
Filter time
constant
Sensor
correction
Indication
time
Auto/Manual
Manual mode
auto return time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default DisplayDefault Display
Default Display
Default Display
Default Display
Default Display
Manual mode auto return
time has elapsed
key
key
key
key
for 3 sec
key
key
key
key
key
key
for 3 sec
key
key
key
key
key
key
key
key
MODE
key
MODE
key
MODE
key
MODE
key
MODE
key
key
for 3 sec
key
key
key
key
key
key
key
key
key
key
key
key
key
for 3 sec
key
key
key
key
for 3 sec
No. 6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
QUICK REFERENCE [Applicable model: SGC, SGCW, SGCL] No. SGC12JE1 2018.10
Input type
4 to 20 mA (
Built-in
50 Ω shunt resistor
)
4 to 20 mA
(250Ω
shunt resistor
)
4 to 20 mA
(50 Ω
shunt resistor
)
0 to 20 mA
(250Ω
shunt resistor
)
0 to 16 mA
(62.5Ω shunt resistor)
2 to 10 mA
(250Ω
shunt resistor
)
0 to 10 mA
(100Ω shunt resistor)
1 to 5 mA
(100Ω shunt resistor)
0 to 1 mA
1000Ω shunt resistor)
10 to 50 mA
(10 Ω shunt resistor)
0 to 10 mV
(Input resi. 1 MΩ)
0 to 50 mV
(Input resi. 1 MΩ)
0 to 60 mV
(Input resi. 1 MΩ)
0 to 100 mV
(Input resi. 1 MΩ)
0 to 1 V
(Input resi. 1 MΩ)
0 to 5 V
(Input resi. 1 MΩ)
1 to 5 V
(Input resi. 1 MΩ)
-5 to 5 V
(Input resi. 1 MΩ)
0 to 10 V
(Input resi. 1 MΩ)
-10 to 10 V
(Input resi. 1 MΩ)
Decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Indication unit
No unit
%
mA
V
°C
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
※1
Output 1,2 decimal point
No decimal point
1 digit after point
2 digits after point
3 digits after point
Output 1,2 Normal/Reverse
Normal
Reverse
Auto/Manual
Auto
Manual
Communication speed
9600 bps
19200 bps
Model Name
Circuit Configuration
SGC, SGCL
SGCW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
lphabet A B C D E F G H I J K L M
Indication
lphabet N O P Q R S T U V W X Y Z
Terminal Arrangement
SGC, SGCL SGCW SGCL only
RS-485 serial communication
Modular jack pin arrangement
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
Key Operation Flowchart
Display Mode
• : Available only for the SGCW.
• For the details of the display mode, refer to the full Instruction Manual.
Default Display
• If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
• Once the Default Display is set, the DISP key will be in lock status.
• If the DISP key is pressed for approx. 3 seconds, the key lock status will be
cancelled.
• If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
Setting Mode
• Output 2 setting mode is available only for the SGCW.
• Communication setting mode is available only for the SGCL.
• If the MODE key is pressed for approx. 5 seconds in each setting mode, the unit
will move to the Default Display.
Abbreviation: Input resi.: Input resistance)
※1 Not available for the SGCW.
For SGCL
和文は裏面をご覧下さい。