TOA YM-1J, YM-3CF, YM-3CM, YS-4CF, YS-4CM User manual

  • Hello! I am an AI chatbot trained to assist you with the TOA YM-1J User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION MANUAL
MICROPHONE CONNECTORS
SPEAKER CONNECTORS
YM-1J
YM-3CF, YM-3CM
YS-4CF, YS-4CM
1. SPECIFICATIONS
2. DIMENSIONS OF MOUNTING OPENING
3. APPLICABLE CABLES
4. CONNECTIONS
Model No. Connector Applicable connector Allowable current (AC) Accessories
YM-1J Double pole jack Single or double pole plug
Screw ........... 2
YM-3CF XLM-3-31PCH-R XLR-3-12C 3 A
YM-3CM XLM-3-32PCH-R XLR-3-11C 3 A
YS-4CF XLR-4-31-F77 XLR-4-12C 10 A
YS-4CM XLR-4-32-F77 XLR-4-11C 10 A
Applicable plate (common to above all models): YP-1AF Plate (optional)
XLM type and XLR type connectors are the products of ITT Corporation.
Plate
Electrical box
83.5 (3.29)
90 – 98
(3.54 – 3.86)
46 – 50
(1.81 – 1.97)
Mounting diagram Dimensions of mounting
opening
according to the mounting dimensions shown at left.
Note
When a low-voltage circuit and a low-power circuit are
housed in the same box, provide a partition to isolate them
from each other.
YM-1J, YM-3CF, YM-3CM Microphone vinyl cable, Cross-sectional area: 0.75 – 2.0 mm² (AWG 18 – 14)
YS-4CF, YS-4CM 600 V vinyl-insulated cable or equivalent, Diameter: 0.8 – 1.6 mm (AWG 20 – 14) or
Cross-sectional area: 0.9 – 2.0 mm² (AWG 17 – 14)
Connection of balanced
double pole plug
Connection of unbalanced
single pole plug
H (+)
C (–) C (–)
E (Shield)
H (+)
E
(Shield) (
–)
[YM-1J]
Short C and E.
H [USA type : – (C)]
C [USA type : + (H)]
E (Shield)
[YM-3CF]
[YS-4CF] [YS-4CM]
[YM-3CM]
H [USA type : – (C)]
C [USA type : + (H)]
E (Shield)
H: Hot
C: Cold
E: Shield
URL: http://www.toa.jp/
133-05-469-30
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,Germany
Unit: mm (in)
Notes
For cables with sectional area of under 0.75 mm
2
, fold back their cores to increase the sectional area before connection.
If a thick cable is used , the circuit board can be damaged when mounting the connector in an electrical box.
Take care that excessive force is not applied to the circuit board when mounting.
Note: As H, C, and E are shorted when not used, mixers or
amplifiers using phantom power cannot be used.
/