SPECIFICATIONS
Delivery Delivery Max. Capacity
Pressure Pressure for Nitrogen
Regulator Range, Gauge, ft
3
/hr (L/min)
psig psig "C" Size 1/2" NPT
Model Part No. (bar) (bar) Outlet Outlet
R-6701 22234 0-15 0-30 2,000 6,000
(0-1.0) (0-2.1) (945) (2830)
R-6702 22235 0-75 0-100 6,000 13,000
(0-5.2) (6.9) (2830) (6150)
R-6703 22236 0-150 0-200 10,000 13,000
(0-10.3) (0-13.8) (4720) (6150)
R-6704 2227920 0-200 0-400 12,000 13,000
(0-13.7) (0-27.6) (5680) (6150)
Capacity will depend on the inlet and delivery pressures, outlet
restriction, and type of gas used (see capacity curves on pg.2).
For other gases, multiply the given nitrogen flow rate by the
following correction factors:
acetylene 1.03 hydrogen 3.68
air 0.97 methane or natural gas 1.31
argon 0.83 oxygen 0.92
carbon dioxide 0.79 propane 0.79
helium 2.61
NOTE: Piped or distributed acetylene pressure should
never exceed 15 psig (1.0 bar).
Gas Service: Any noncorrosive industrial gas.
Max. Inlet Pressure: 400 psig (27.6 bar).
Max. Inlet Pressure: 400 psig (27.6 bar).
Inlet and Outlet Connections: 1/2-in.—14 NPT fe-
male.
Operating Temp. Range:–40 to160
o
F; (-40 to 71
o
C).
Dimensions: 3-in. dia. x 6-in. (89 mm dia. x 165 mm).
Weight: 4.8 lbs. (2.2 kg)
DESCRIPTION
The R-6700 Series Regulators were designed for high
capacity service, such as multiple-torch or multi-sta-
tion operators or a single equipment requiring high
gas consumption. They can be installed for either
station service or for supplying gas through a pipe-
line. The 1/2-in. NPT inlet and outlet female connec-
tions are "in-line" or 180
o
apart, as well as the 1/4-in.
NPT gauge ports. Each regulator is equipped with
the delivery pressure gauge with the other gauge port
plugged. The gauge and the pipe plug may be inter-
INSTRUCTIONS for
F-15-396-B
January, 2000
R-6700 HIGH CAPACITY
PIPELINE - STATION REGULATORS
Be sure this information reaches the operator.
You can get extra copies through your supplier.
changed if a more convenient reading position is de-
sired after installation.
NOTE: If regulator is to be used for supplying oxygen
or a fuel gas from a station outlet for an oxy-
fuel gas process, a suitable shut-off valve and
check valve (or hydraulic back-pressure valve
for fuel gas if desired) must be installed be-
tween station outlet and regulator to prevent
possible backflow. For additional information,
refer to the latest National Fire Protection
Association's Standard, NFPA No. 51.
OPTIONAL ACCESSORIES
Shutoff Valve (V-35, P/N 998210; V-53, P/N 639674;
or V-54, P/N 998184) and CV-5 Check Valve Adaptor
(P/N 639717); Available to meet the latest requirements
of NFPA No. 51 when using an R-6700 regulator for sta-
tion service. The V-35 and V-53 are in-line, ball-seat
type valves with 3/4-in. NPT female connections that
fully opens on 1/4 turn of the handle. The V-35 has
replaceable seat seals. The V-54 is a 90
o
throttle type
valve with 3/4-in. NPT male inlet and female outlet. The
CV-5 is a 3/4-in. NPT male x 1/2-in. NPT male adaptor
with a built-in check valve for coupling any of the shutoff
valves to an R-6700 regulator.
Hose Outlet Adaptor: The following 1/2-in. NPT male
x "C"-size adaptors are available for connecting "C"-
size hose from outlet of regulator to the gas using equip-
ment:
Oxygen "C" ................ (7/8 - 14 male R.H.)P/N 18Z55
Fuel Gas "C"...............(7/8 - 14 male L.H.)P/N 18Z08
Inert Gas "C"......... (7/8 - 14 female R.H.)P/N 639377
INSTALLATION
Since the regulators are provided with pipe con-
nections for direct attachment to any pipeline, a
responsible person must determine that a regula-
tor is installed in the correct, properly labeled pipe-
line. Also a regulator must not be changed from
one gas service to another until a responsible per-
son has determined that it is safe to do so.
These INSTRUCTIONS are for experienced operators who are familiar with the principles of operation and safe practices in handling
gases and gas regulation equipment. If you are not sure that you understand the principles fully, your ESAB representative can supply
you with additional instructions.