Artico SY-AC900 User manual

Category
Mobile air conditioners
Type
User manual

This manual is also suitable for

Welcome
Thank you for purchasing the new Portable Air Condition SY-AC1200. Read this
instruction booklet carefully in order to benefit fully from this product. Store the user
manual in a safe place for future reference.
Important Safeguards
Please read the Manual carefully before operating the machine
ELECTRICAL CONNECTIONS:
Before plugging the appliance into the socket, check that:
. The voltage corresponds to the value indicated on the rating plate
that is located on the back of the appliance.
. The power socket and the electrical circuit are suitable for the
device.
. The socket matches the plug. If not, have the plug replaced.
. The power outlet is properly grounded. Failure to comply with these
instructions
exempts the manufacturer from all liability.
The appliance is for indoor use only.
Place the air conditioner on a fat surface and keep it placed vertically to ensure the
normal operation of its compressor.
This appliance is for domestic use only and not for commercial use.
Before inserting, the mains plug into the socket, check that the mains supply voltage
and current rating corresponds with the power supply details shown on the rear
specification plate of the unit.
Read all instructions, Rated Power Supply: Please connect the unit with Grounded
Power Source: 220-240VAC, 50HZ.
Never share the power outlet with other appliances
Never connect or disconnect the power plug with wet hands to avoid electric shocks
Disconnect the power plug before dismantling, assembling or before cleaning.
Avoid touching mobile parts of the appliance.
Never insert fingers, pencils or any other objects though the guard whenever the
power plug is connected, especially while running.
Persons (including children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge do not intend this appliance for use, unless
a person responsible for their safety has given them supervision or instruction
concerning use of the appliance
The appliance is not intended for use by young children or infirm persons unless
they have been adequately supervised by a responsible person to ensure that
they can use the unit safely.
Young children should be supervised to ensure that they do not play with the
appliance.
Do not use the appliance for any other purposes than its intended use.
The appliance must not be used if the guards are not fasten according to the
instructions.
When the power cord is damaged, it must be replaced by the manufacturer or its
service agent or a similar qualified person in order to avoid hazard
Do not use your appliance with an extension cord or adapter unless it has been
checked and tested by a qualified electrician or electrical supplier
In the case of any malfunction, return to an authorized service agent. Never open the
unit and try to repair it by yourself.
The air conditioner unit must always be stored and transported upright,
otherwise you may cause irreparable damage to the compressor; in case of
doubt we suggest to wait for at least 24 hours before you start air-
conditioning unit.
Avoid restarting the air conditioning unit unless 3 minutes have passed since
being turned off, or the compressor may be damaged.
Never use the mains plug as a switch to start and turn off the air conditioning
unit. Use the provided ON/OFF switch located on the control panel.
Do not place the Portable Air conditioner next to heat sources or direct sunlight.
Always place the portable air conditioner on a dry stable place.
Always use the original supplied accessories. Any third party accessory might
damage the appliance.
The ideal environmental temperature for the portable air conditioner should be 15-
35ºC.
The appliance shall not be installed in the laundry.
The appliance must be positioned so that the plug is accessible and it shall be
installed in accordance with national wiring regulations.
Clean the portable air conditioner according to the manual reference
The tension of the portable air conditioner must meet the requirements. Any damage
incurred by an incorrect power source is not included in the warranty.
Do not place the portable air conditioner in any place with water or other liquid.
Prevent water or any liquid from entering the portable air conditioner.
Use the accessories provided by the manufacturer of the portable air conditioner;
otherwise, the portable air conditioner may damage.
The following ambient temperature is suggested for the portable air conditioner
(cooling / heating): 15-35 ºC / 5-27 ºC.
Special warning
Place the A/C on even ground and install it vertically so as to ensure normal
operation of the compressor.
The A/C should be at least 50cm away from surrounding objects. Keep air inlet
and outlet smooth.
Do not operate the A/C near gasoline or any other inflammable liquid.
Do not use spraying agent and other solvent or flammable substances near the
A/C; otherwise, its plastic may deform and electric parts may be damaged.
Do not expose the unit under direct sun light to avoid surface color fading
Do not tilt the unit more than 35 degrees or upside-down while transporting
Energy Saving Tips
Do not cover or restrict the airflow from the Outlet or Inlet grills.
The minimum distance from furniture and wall should be 50CM.
Keep the filters clean. Under normal conditions, the filters should be cleaned
approximately every 30 days. Since the filters remove airborne particles, more
frequent cleaning maybe necessary, depending on the indoor air quality.
Set the fan speed switch to high cool and the thermostat to the coolest position for
the initial start-up, then set the fan switch to Low cool and lower the thermostat to a
comfortable setting.
Suggestions
If you want to get better effect, we suggest you not to use cooling function when
ambient environment is higher than 35 ºC.
Basic functions
This unit offers cooling, dehumidifier and fan mode, ideal for home and office
use.
The unit include 3 fan-speed level accessible by the panel control or the remote
control.
This unit is designed with various protection functions such as 24 hours
programmable timer, auto condensation, intelligent temperature sensor and
water control with warning.
The ideal temperature for using the portable air conditions is from 15ºC~35ºC.
Parts of the SY-AC1200
1. Top cover
2. Air outlet grille
3. Control panel
4. Front cover
5. Caster
6. Handle
7. Power cord
8. Drain port
9. Upper filter frame
10. Protective net
11. Lower filter frame
12. Water plug
13. Remote control
14. Exhaust hose
15. Window kits
16. Hose adaptor
Installation
Warning: Before using this unit, it is important to keep it upright for at least 2 hours.
The unit can later transported to another room. Please note the following instructions:
Assemble hose adaptor (picture 1)
Picture 1
1. Prepare the male and female parts of the hose adaptor.
2. Each side holds one part and can be assembled easily.
Remark: Do not push too hard to prevent any damage.
Assembly of the exhaust hose (picture 2)
(Picture 2)
1. Lengthen one head of the hose; screw it into the unit in an anti-clockwise manner.
2. Remarks: screw it into its place, no less than three rounds.
3. The same way to connect the hose to the assembled adaptor( At least three circles)
Installation of window kits
1.
Partially open the window and then fix the window kits to the window (pictures 3 & 4 below).
2.
The window kits can be installed on most normal and vertical windows, and adjustable.
(Picture3) (Picture 4)
Please make sure the unit is upright.
1.
The unit should be placed on a flat floor and 50cm away from surrounding objects
(Picture 5)
(Picture 5)
2.
Fix the other end of the exhaust hose to the air-outlet window kit (pictures 6 & 7)
(Picture 6) (Picture 7)
Warning:
The length of the soft tube extends from 28cm to 150cm, which is exclusively built for this model.
Do not use the fully lengthened hose or any other hoses instead as this will cause damage to the
unit. The air-exhaustion pipes and openings must have a good ventilation If not the unit may
overheat causing it to malfunction.
Please note: Do not bend the tube at any time, as this will cause damage to the tube.
Controls and Settings
The portable air conditioner (Cooling only) has three main functions: cooling, dehumidifying and fan.
(Please refer to the below diagram picture)
Display Fan
Timer Mode Sleeping area Swing speed Max cool
Up On/Off
Down Signal
Receptor
1.1
When you first plug in the unit, it will enter into standby status. The digital screen will
indicate the temperature (Range: 535 ºC / 4195 ºF). If the ambient temperature is
above 35 ºC, the screen will show “H”. If it is below 5 ºC, it will indicate “L” and the unit
will enter into standby status.
1.2
ON/OFF button: When you press the On/Off button, the unit will enter into cooling
mode (Setting temperature 24 ºC /75 ºF), and the speed of the fan will be on high. Press it
once again to turn off the unit.
1.3
Mode button
Press the Mode button to select between Cooling, Fan, or Dehumidifying Mode.
1.4
Fan Speed button
Press the Fan button to change between the 3 speed levels.
HIGH MEDIUM LOW
a. Under cooling mode (High/Medium/Low)
b. Under fan mode: (High/Medium/Low)
c. Under dehumidifying mode, the fan only works on low speed.
d. If you switch between cooling and fan modes, the fan speed will not change.
1.5
Timer button:
Press the button and the icon will start to flash. Set the hours and minutes using the
buttons.
Adjust the hours and the minutes as per your choice. The interval in the hours is one hour
and those in the minutes in intervals of 10.
The Auto-shut-off timer is only available when the unit is on.
The Auto-run timer is only available when the unit is off.
Once the timer is set, the icon will keep on flashing until it reaches the due time. If
the timer needs to be set again, the previous record will be deleted automatically.
1.6
Up and Down buttons
Use the Up and Down buttons to set the temperature and timer.
When in cooling mode, the temperature ranges from 1830 ºC / 6486 ºF.
Press the Up and Down buttons simultaneously to switch between ºC and ºF
1.7
Sleeping key :
When in cooling mode, press the Sleep key to turn the unit into sleeping mode.
The temperature will automatically adjust to 27ºC and the fan will run at the low speed. If the room
temperature is <27ºC the compressor will be off. When the temperature of the room raises over
>27ºC, the compressor will automatically start to work. The LCD will indicate icon. Press the
same button once again to cancel the Sleeping function.
1.8
Swing button :
Press the swing key to activate the auto swing function. This will circulate the air in a uniformly
manner in the room. Press it once more to off the function.
1.9
Max cool key :
The portable Air conditioner cooling mode only works when the room temperatures is above
18ºC. If the temperature ambiance is below 18ºC, the unit will only work under Fan mode or
dehumidifying mode.
The Max Cool function ignores all the above and when activated will work under cooling mode
under any temperature range. The speed of the fan is automatically set to the highest level.
(This function is ideal to lower quickly the temperature of a room)
Remote control
LOCK RESET
Pow
er
:
Press the Power key to turn on or off the unit.
Mode :
Press the Mode key to select between cooling, dehumidifying or fan function.
Up :
Press the Up key to increase the temperature or adjust the time.
Down :
Press this down key to decrease the temperature or adjust the time.
Fan :
Press the Fan key to set the fan speed.
Swing :
Press the Swing key to activate the Auto swing function.
Temperature :
Press this key to select between Celsius and Fahrenheit.
Sleeping :
Press the Sleeping key to
enable
this function. (Only
under
cooling
function
)
Timer :
Press the Timer key to set the time. The first 5 hours can be set in intervals of 30 minutes. The
remaining hours can only be set in fractions of hours. Once the timer has been set, the number will
blink 5 times on the remote control to confirm the setting.
Max. Cool :
Under cooling mode, press the Max key to achieve the maximum output.
Keypad lock: Use a thin pointed device to lock the buttons of the remote control. A lock appears on
the display as per the following picture . Press the same key once again to unlock all the buttons
and be able to use the remote control again. (This function can prevent children from using the unit
without supervision)
Reset: Use a thin pointed device to press the “Reset” key on the remote control. The remote will set
all its parameters back to the default settings.
Important Note:
Never turn off the air conditioner by unplugging it from the power supply or pulling it from
the cord. Always press the "On/Off" button and wait a few minutes before unplugging it. This
allows the device to perform a check cycle to verify operation.
Anti-freezing protection control
When in Cooling mode, if the compressor has worked for over 10 minutes and the copper coil
temperature is continuously <2ºC for over 20 seconds, then the compressor and water motor will stop
working and the LCD will display E4. The unit at this moment initiates the anti-frost protection and all
buttons on the control panel (except for power button) are inactive.
Once the copper coil temperature increases back to >8ºC, the anti-freezing protection will stop
automatically and the compressor, water motor will start working once again and the machine will
recover back to its previous operating state, (in order to protect the compressor, it will be restarted 3min.
later)
Water-full protection
When the water level in the water plate exceeds the warning level, the machine will alert the user
automatically and the LCD will display “FL”. You will need to drain the water from the machine following
the section of “Water Drainage”
Compressor delay-protection
The compressor will always have a small delay of about 3 minutes in order for it to begin. This means
that the compressor is in recovery mode. Only during the first use of the unit, the compressor will come
on immediately.
No refrigerant protection
When in Cooling mode and dehumidifying mode, if the compressor has worked for over 10 minutes, but
the temperature difference between the coil temperature and the room temperature is still less than 3
ºC and this temperature difference has lasted for over 30 minutes, the machine will enter into no-
refrigerant protection. This means, there is no refrigerant in the unit, so the compressor and water
spring motors will stop working, the down fan will stop running, the up fan will run at low speed and
lastly the LCD will display E3.
Water Drainage
The product has an automatic water evaporation system. The circulation of condensed water, cools
down the condenser. This not only increases refrigeration efficiency but also saves energy.
1. Manual drainage :
a. When the water tank is full and the unit stops working, please turn off the unit and unplug it
from the mains. Please do not move the unit abruptly, or the water will spilt out from water
recipient.
b. Screw off the water cover and unplug the water blocker. (Please see part 12 under section
“Parts of the SY-AC1200”)
c. Use a water container to remove the water from under the unit.
d. When the water is out, plug in the water blocker once again and screw on the water cover
properly. (Please see part 12 under section “Parts of the SY-AC1200”)
2. Continuous drainage:
a. Screw off the water plug and unplug the water blocker. (Please see part 12 under section
“Parts of the SY-AC1200”)
b. Use a water pipe to connect it to the water outlet. Lead the pipe to the outside or
washroom.
c. When the water is out , plug in the water blocker and screw on the water cover (Please
see part 12 under section “Parts of the SY-AC1200”)
This model has a self-evaporative function, under the cooling mode it is recommended not to use
continuous drainage in order to get a better cooling effect.
Maintenance
Cleaning
Please turn off the unit and unplug the unit before cleaning or carrying out any sort of maintenance
Cleaning the surface
Clean the housing with a duster or a soft wet cloth. Do not use any chemical solvent (such as benzene,
alcohol, gasoline). The surface may damage or may even deform the complete outer casing.
Air filter cleaning
Clean the air filters every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce.
1)
Pull the filter out towards you and then pull it up as shown below.
2)
Wash the air filters by immersing it gently into warm water (about 40
ºC
) with a neutral detergent,
rinse it and dry it thoroughly in a dry place.
3)
Install the air filters carefully after cleaning the filters. Make sure these are well assembled before
using the unit again.
Open from here
If the filter is not too dirty, If the filter is very dirty,
use a vacuum cleaner clean it with warm water
to suck the dust. The ideal temperature of the water is 40ºC
(Picture 8)
After Season Maintenance
1.
Pull out the plug in a drainage hole and empty the water-receiving plate, or drain out the water by
leaning the unit. Then enter into the fan mode, and press the button for 5 seconds until it sets to the
low fan speed. Keep this mode on for half a day until its inside becomes dry.
2.
Turn off the unit and pull out the plug.
3.
Clean its filter screen and reinstall back.
4.
Tie the wire and bind it together, then put it into the accessories storage space.
5.
Remove the exhaust pipe and accessories and keep them safely.
6.
Put the unit into a plastic bag, and then keep it in a cool and dry place.
7.
Take out the batteries of remote control and safely keep them.
* All accessories can be placed in the accessories storage on the back of the unit.
Using the unit after a long time
1. Check whether the water plug and filter screen are installed.
2. Check whether the power cord is intact. If it has any signs of breakage, do not use the A/C
3. Reinstall the remote control batteries.
4. Reinstall other parts following the installation instructions.
Troubleshooting
Do not attempt to disassemble, repair or alter the equipment yourself. This will void the warranty.
The following table lists the common failures and maintenance methods of the series of portable air
conditioners. When the machine runs abnormally, the following table can be a simple diagnose and
repair prescription. If the problem persists, contact Sytech Technical service center.
TROUBLE POSSIBLE CAUSE SOLUTION
The A/C doesn’t
work
Not plug in Plug in
The display panel displays
“P2”
Restart the A/C after power off and
drainage process. The unit should work
fine.
The Off timer function is activated
Restart the unit after turning it off for 3
minutes.
The refrigeration
effect of the
conditioner is not
good
Direct sunlight Draw the curtain
Doors or windows
are open. Room
is too crowded or heat source
placed in the room
Close the doors and windows and remove
the heat source
Dirty filter screen Clean or replace the filter screen
Air inlet or air outlet is blocked
Remove the blockage
The air conditioner
makes too much
noise
The A/C is not placed on a flat
level
Place it on a flat and solid surface and try
avoid shaking.
The compressor
Does not work
The compressor delay protection
has been activated
Wait 3 minutes and restart the machine
when its temperature is reduced.
E1 on LCD Coil temperature sensor failure check coil temperature sensor or relevant
circuit
E2 on LCD
Indoor temperature sensor failure
check room temperature sensor or
relevant circuit
E4 on LCD
Anti
-freeze protection. When the
coil temperature is below 0ºC, the
whole machine will stop. When the
coil temperatures raises to 8ºC or
more, the protection will
disconnect and the unit will restore
to its original working state.
Wait for the coil to defrost. The machine
will
restart automatically.
Remote control
doesn’t work
The distance is too far.
Get closer to the unit and aim the remote
control to the Air outlet grille
Control panel has not received the
signal from remote control.
The batteries are weak.
Change the batteries
Important information for the correct disposal of the product in accordance with
directive 2002/96 / EC.
At the end of its useful life, the product should not be disposed off with household
waste. It must be taken to a special selective collection center of the municipal
agencies or to a distributor who presents this service. The correct elimination of an
electrical appliance avoids possible negative consequences for the environment and
health derived from an inadequate elimination and allows to recover its materials to
obtain significant savings in energy and resources. As a reminder of the need to
dispose of the appliances selectively, the product is marked with a trash can with
wheels crossed with an X.
DECLARATION OF CONFORMITY
Manufacturer Name: Satyatrade S. L.
Address: Pol. Ind. La Raya. C/ Guadalquivir, 2.
Camarma de Esteruelas, 28816 Madrid
Tel: 902 430 967
Fax: 91 8864285
NIF: B83254763
Manufacturing country: China
Description: Portable Air Condition
Sytech® SY-AC1200 complies with the following directives:
EMC Standard: Directive 2014/30/EU
LVD Standard: Directive 2014/35/EU
EER Standard: Directive 2009/125/EC
ROHS Standard: Directive 2011/65/EU Restriction of Hazardous Substances
Signed: Ajeet Nebhwani Utamchandani
Sole Administrator
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Artico SY-AC900 User manual

Category
Mobile air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI