MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
Steel barrel
Digital pressure gauge
Steel base
Valve
disconnected
Valve connected
= pump
Ergonomic two-component handle
Valve head
GERMANY
Inbus 10
18
18
MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
Exchange gauge oor pumps
1. Loosen the union nut on the pressure gauge cap. 2. Pull up the pressure gauge cap.
3.
Unscrew the pressure gauge at the bottom with
an Allen key (size 10).
4.
Insert a new pressure gauge into the pressure gauge holder.
5.
Screw on the pressure gauge with a
maximum torque of 2 Nm.
6.
Push the pressure gauge cap down again
and secure it with the union nut.
GERMANY
MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
Exchange rubber sealing cuff oor pumps
1. Remove the two Torx screws (T25)
of the hose holder. Pull the cylinder
rod out of the tube with a strong jerk.
3. Place the new cup over the cylinder rod until it is
positioned in the designated joint.
CAUTION: Make sure that it is on the correct side!
2. Remove the old cup seal. If necessary,
use a tool to do this (e.g. screwdriver).
4. Grease the rubber cup seal,
re-insert the cylinder rod and screw it in.
GERMANY
18
Inbus 10
45˚
MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
Exchange recovery system
1. Loosen the union nut on the pressure gauge cap.2. Pull up the pressure gauge cap.
3. Unscrew the pressure gauge at the bottom
with an Allen key (size 10).
4.
Turn the pressure gauge holder approximately
45° anti-clockwise until you feel resistance.
Then pull out the pressure gauge holder.
5. Replace the non-return valve system and follow
the steps mentioned above in reverse order.
6. ATTENTION: Please make sure that the non-return
valve system is correctly positioned in the designated
 xing.Checkthatthespringisttedsecurely!
GERMANY
AUTO
SCHRADER
SCLAVERAND
PRESTA
DUNLOP
MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
1. Remove cross-headed screws.
2. Remove the cap and seals.
3. Insert new seals.
4. Replace the cap and screw it tight.
ATTENTION: Different seals for Schrader and Presta.
Exchange valve seals
GERMANY
PSI
BAR
BAR/PSI
PSI
BAR
BAR/PSI
Please change the battery as follows:
2. Unscrew the two Phillips screws on the underside
 oftheoorpumpbase.
4. Now screw the battery compartment cover back on.
(CAUTION: only tighten the screws so that they are hand tight.)
3. Lift the battery compartment cover off and replace the batteries (2 x 1.5 V AAA). It is imperative that
you note the Plus and Minus symbols at the edge of the battery compartment. Insert the batteries so
that the plus terminal is placed on the positive side and the minus terminal of the battery is placed on
the negative terminal so that the symbols can be seen.
1. If the battery of the digital manometer is empty,
the following symbol appears in the lower right corner.
MANUAL ¬ AIR-X-PLORER DIGI 10.0 ¬ 11664 ALLROAD ROAD MOUNTAIN
Changing the battery
Plus terminal top
Minus terminal top
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

sks AIR-X-PLORER DIGI 10.0 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI