states a hazard
may cause serious injury or
death if precautions are not
followed.
Mechanical 30-Minute Timer
For MrSteam CU Commercial Steambaths
mr.steam® 30-MINUTE TIMER
_______________________________________________________________________________________________
Installation and Operating Manual
CU-99216B
IMPORTANT NOTE:
As you follow these instructions, you will notice
warning and caution symbols. This information is important for the safe
and efficient installation and operation of this generator. These are types
of potential hazards that may occur during this installation and operation:
FUNCTIONALITY OF THE TIME SWITCH
The CU Mechanical Timer will turn the steam solenoid on. During the preset running time, the
normally open (N.O) switch activates the connected steam solenoid by closing the circuit. After the
time has elapsed, the switch opens and deactivates the connected steam solenoid by opening the
circuit again. To set the timer to the desire time setting, turn clockwise. Timer circuit will remain
closed, until timer reaches the zero point. The boiler will no longer be energized at the zero point.
BEFORE USE
Before installing and using this timer, it is absolutely necessary that you read this operating manual thoroughly.
SAFETY INSTRUCTIONS
This timer may only be installed by a qualified, licensed electrician and must be installed in accordance with
National and local codes.
SHOCK HAZARD! Install the timer per these instructions before connecting to the main
supply. Never touch live contacts or components.
Protection from contact with the line voltage components must be achieved by proper installa-
tion in a 2 x 4 junction box. When installing the timer, ensure the fastening sliders prevent the timer from being
removed.
DO NOT install the timer in a wet or damp location.
DO NOT install the timer inside the steam room.
1. INSTALLING THE TIMER
Figure 1 shows the default position of the
normally open 30-minute timer switch
.
signals a
situation where minor injury or
product damage may occur if
you do not follow instruc
tions.
Maximum run time can be set up to 30 minutes.
CAUTION
!
WARNING
!WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
PUR 100565 REV 7/19
43-20 34th Street, Long Island City, NY 11101 718-937-4500 • 9410 S. La Cienega Blvd., Inglewood CA 90301 310-216-6565
Figure 1
MPORTANT NOTE:
Only use the normally open
(N.O.) terminal when wiring the mechanical timer.