Pepperl+Fuchs LGC2 is a level probe designed for use in hazardous areas. It has an Equipment Protection Level (EPL) of Gb and a type of protection of Ex ia IIC T6...T4. This means that it can be used in areas where there is a risk of explosion due to the presence of flammable gases or vapors.

The LGC2 is a versatile device that can be used for a variety of applications, including:

  • Level measurement in tanks and vessels
  • Interface measurement
  • Overfill protection
  • Dry run protection

The LGC2 is easy to install and maintain. It is also highly accurate and reliable.

Here are some of the key features of the LGC2:

Pepperl+Fuchs LGC2 is a level probe designed for use in hazardous areas. It has an Equipment Protection Level (EPL) of Gb and a type of protection of Ex ia IIC T6...T4. This means that it can be used in areas where there is a risk of explosion due to the presence of flammable gases or vapors.

The LGC2 is a versatile device that can be used for a variety of applications, including:

  • Level measurement in tanks and vessels
  • Interface measurement
  • Overfill protection
  • Dry run protection

The LGC2 is easy to install and maintain. It is also highly accurate and reliable.

Here are some of the key features of the LGC2:

SI00455O-A/98/EN/06.09
71342916
Instruction Manual
Level Probe
LGC2
IECEx: Ex ia IIC T6...T4 Gb
SI00455O-A
Safety instructions for electrical apparatus for explosion-hazardous
areas according to IEC standards
Level Probe LGC2
SI00455O-A
DOCT-5523 2017-12 303225
2
Level Probe LGC2
SI00455O-A
DOCT-5523 2017-12 303225
3
EN
Level Probe
LGC2
Associated
Documentation
This document is an integral part of the following documents:
BA01605O, KA01244O
The documents which are supplied and correspond to the device type apply.
Supplementary
Documentation
Explosion protection manual
Manufacturer's
certificates
IECEx certificate
Certificate number: IECEx DEK 17.0045
Affixing the certificate number certifies conformity with the standards under www.IECEx.com
(depending on the device version).
IEC 60079-0:2011
IEC 60079-11:2011
Designation Explanation of the labelling and type of protection can be found in the explosion protection manual.
Designation according to IECEx
Equipment protection level (EPL)
Gb
Designation of type of protection Ex ia IIC T6...T4
Level Probe LGC2
SI00455O-A
DOCT-5523 2017-12 303225
4
EN
Safety instructions:
Installation
Figure 1
A Zone 1 or Zone 2
BZone 1
1
only for versions with outside diameters 22 mm and 42 mm.
Comply with the installation and safety instructions in the manual.
Install the device according to the manufacturer's instructions and any other valid standards and
regulations (e. g. IEC/EN 60079-14).
The type of protection changes as follows when the devices are connected to certified
intrinsically safe circuits of Category ib: Ex ib.
When interconnecting intrinsically safe circuits, take into account sensor capacitance and
length-dependent cable capacitance and inductance (see table).
Connect cable screen to earth ground of the installation.
The intrinsically safe input power circuit of the device is isolated from ground potential and has a
dielectric strength of at least 500 V
rms
with respect to it.
When shortening the length of the cable ensure that this dielectric strength is maintained for
connection wires and earth grounded screen.
Avoid impact and friction sparks (anchor equipment if necessary/secure against swinging).
Avoid electrostatic charging of the plastic surfaces (especially at the version with outside
diameter 29 mm and at the terminal box).
Do not rub. Do not use in media or environments which may generate electrostatic charges on
the plastic surfaces.
(+)
(–)
1
A
B
Level Probe LGC2
SI00455O-A
DOCT-5523 2017-12 303225
5
EN
Terminal Box
Figure 2
1 Functional earth terminals
2Isolation platesn
3 Signal terminals
Use a connecting cable for continuous duty temperature
85 °C.
Do not remove or move terminal blocks, isolation plates or fastening elements.
Do not build in additional components.
Temperature tables
Terminal box
Connection data
1
2
3
Ambient temperature range Temperature class Max. ambient temperature
-10 °C  T
amb
 +70 °C T4 +70 °C
T5 +55 °C
T6 +40 °C
Ambient temperature range Temperature class
-40 °C  T
amb
 +80 °C T6
Electrical data
U
i
30 V DC
l
i
133 mA
P
i
1 W
Sensor:
C
i
10.3 nF, L
i
= 0
Cable:
C
i
180 pF/m, L
i
1 H/m
Level Probe LGC2
SI00455O-A
DOCT-5523 2017-12 303225
6
EN
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of
Delivery for Products and Services of the Electrical Industry, published by the Central Association of the
"Elektrotechnik und Elektroindustrie (ZVEI) e.V." including the supplementary clause: "Erweiterter Eigentumsvorbehalt".
Subject to modifications
Copyright Pepperl+Fuchs Printed in Germany
www.pepperl-fuchs.com
Worldwide Headquarters
Pepperl+Fuchs GmbH
68307 Mannheim · Germany
Tel. +49 621 776-0
For the Pepperl+Fuchs representative
closest to you check www.pepperl-fuchs.com/pfcontact
PROCESS AUTOMATION
PROTECTING YOUR PROCESS
SI00455O-A/98/EN/06.09
FM7.2
DOCT-5523 303225
12/2017
71342916
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Pepperl+Fuchs LGC2 User manual

Type
User manual

Pepperl+Fuchs LGC2 is a level probe designed for use in hazardous areas. It has an Equipment Protection Level (EPL) of Gb and a type of protection of Ex ia IIC T6...T4. This means that it can be used in areas where there is a risk of explosion due to the presence of flammable gases or vapors.

The LGC2 is a versatile device that can be used for a variety of applications, including:

  • Level measurement in tanks and vessels
  • Interface measurement
  • Overfill protection
  • Dry run protection

The LGC2 is easy to install and maintain. It is also highly accurate and reliable.

Here are some of the key features of the LGC2:

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI