Lefroy Brooks BL 1550 Installation & Servicing Guide

Type
Installation & Servicing Guide

This manual is also suitable for

1180 / 1550
MONOBLOC MIXER
INSTALLATION GUIDE
2
IMPORTANT INFORMATION
Professional installation
We recommend that our products are fitted
by a fully qualified professional plumber. They
should be installed correctly and in accordance
with all local water regulations and the system
protected by non-return valves (not supplied).
All products should be accessible for routine
servicing.
Suits all systems
This Lefroy Brooks product is potentially
suitable for every possible application, type of
boiler and water supply pressure. However,
if your supply pressure is below 1 bar it is
advisable to fit a water pump. For systems with
combination boilers, it is not advisable to fit
pumps (refer to boiler manufacturer).
Supply temperature safety notice
A thermostatic mixing valve (TMV) should
be fitted (not supplied) to the hot supply to
restrict the temperature to a safe working/
maximum temperature to comply with local
building regulations, current legislation, relevant
standards and codes of practice. Maximum
allowed temperatures vary subject to type of
installation or specification of building.
Flushing system
It is most important to flush out all pipework
thoroughly before connecting the monobloc.
Failure to do so is the single most common cause
of cartridge failure.
Supply connections
We recommend the installation of individual
isolation valves. The hot and cold water hoses
should be connected to suitable ½" BSP
connectors.
Balancing flow
If a significant pressure dierence exists between
the hot and cold supplies, we advise fitting a
‘flow regulator’ (not supplied) to the higher or
both supplies.
Water quality
In hard water areas, a suitable water treatment
system should be provided to prevent limescale
deposits (calcium deposits) which may eect
the long term performance of the ceramic
cartridges. Exterior surfaces should be gently
wiped with a dry soft cloth after use to minimise
water stains and limescale deposits.
Servicing
All serviceable parts are available to maintain
your Lefroy Brooks product.
312mm
152mm
196mm
35mm maximum
mounting surface
Hoses:½" BSP x 350mm long
Ø50mm
Ø30mm
166mm
HOT supply COLD supply
The recommended mounting surface opening is Ø30mm nominal.
3
DIMENSIONS FOR 1180 MODELS
Not to scale
360mm 240mm
200mm
35mm maximum
mounting surface
The recommended mounting surface opening is Ø30mm nominal.
Hoses:½" BSP x 350mm long
Ø50mm
Ø30mm
166mm
HOT supply COLD supply
4
DIMENSIONS FOR 1550 MODELS
Not to scale
These results have been taken directly from the ow chart on the system
Flow (Litres/minute)
Static Pressure (Bar)
3.0
2.0
1.0
10 20 30
5
Note: The balanced pressures shown are applied directly to the inlets; flow rates indicated are free
flowing and may vary subject to restrictions created by installation, pipework, layout or application.
The mixer has a dual flow spout. This is a safety feature that provides a cold water jacket around the hot
water carrying central pipe. During normal use the spout will be cool to the touch. To benefit from this
safety feature the HOT supply must be connected to the LEFT hose and the COLD supply to the RIGHT
hose (facing the front of the mixer).
TYPICAL FLOW RATES
UNDERSTANDING THE DUAL FLOW SPOUT
Underside of monobloc
Underside of monobloc
6
INSTALLATION
A
1 There are three holes in the base of the
monobloc body. Use a flat bladed screwdriver
to screw the threaded tail into the smaller of
the three (A).
2 One of the hoses has a shorter connector
than the other. Screw the hose with the
shorter connector into one of the holes in
the underside of the monobloc. The ‘O’ ring
on the hose will provide a water tight seal
so additional sealing compound should be
required.
B
7
3 Place the deck plate and deck plate ‘O’ ring
over the hose (C).
4 Feed the hose on the monobloc through the
Ø30mm hole in the mounting surface (D).
5 From the underside of the mounting surface,
feed the remaining hose through the hole (E).
Screw this into the base of the monobloc.
C
D
E
Nut
‘C’ shaped clamp
‘O’ ring
Washer
Mounting surface
8
6 Feed the washer and ‘O’ ring onto the hoses.
7 With the recess facing upward, locate the ‘C
shaped metal clamp beneath the washer and
‘O’ ring. Slide all three along the hoses until
they come into contact with the underside of
the mounting surface, ensuring that the hole
in the ‘C’ shaped clamp has passed over the
threaded tail.
8 Locate and screw the locking nut onto the
threaded tail, but hand tight only. Ensure
the monobloc is positioned as required then
tighten the nut with a spanner to secure the
monobloc. Be careful not to over tighten as
this may cause damage.
Washer
Aerator
Cover
9
SERVICING – CLEANING THE SPOUT AERATOR
1 There is an aerator located in the end of the
spout. To remove the aerator unscrew and
remove the aerator cover.
2 The aerator can be cleaned in warm soapy
water or replaced. Rinse well after cleaning.
3 Check the spout for debris and limescale.
Wipe clean as required.
4 Assemble in the reverse order.
Shown with 1550 model fitted with white levers. The same procedure applies to all models.
Upper ‘O’ ring
Lower ‘O’ ring
Acetal bush
Front of spout
Gap
* Following ‘O’ ring replacement, before fitting the spout, ensure the gap in the acetal bush faces the
front of the spout.
PSH028 –
Aerator & housing
PSP067 * –
Spout ‘O’ rings
PHL016 – White lever ceramic (single)
PHL020 – Black lever ceramic (single)
PTS007 –
Fulcrum screw
PHL035 –
Cartridges (Pair)
PSH095 –
Braided hoses (Pair)
PSH126 * –
Acetal bush
10
REPLACEMENT PARTS
Shown with 1550 model. Applies to 1180 & 1550 models.
11
FAULT FINDING
The hot/cold valves are turned o but the spout drips continuously.
Replace the ceramic cartridge(s). See opposite for spare part number.
Water flow from the spout is reduced.
Debris from the water supply may be causing restriction at the aerator located in the end of the spout.
The aerator can be removed for cleaning. See ‘servicing – cleaning the spout aerator’ section.
Water leaks from the base of the spout.
Replace the spout ‘O’ rings. See opposite for spare part number.
Note: Following ‘O’ ring replacement, before fitting the spout, ensure the gap in the acetal bush faces the
front of the spout.
Whilst every effort is made to ensure the accuracy of these, they are subject to change without
notice as part of the company’s product development process. The use of trademarks, product design
and artwork is subject to licence or agreement with LBIP Ltd. The design registrations, trademark registrations
and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited.
The right to modify designs and dimensions is reserved. LBIP Ltd is a member of ACID (Anti Copying in Design). E&OE
© LBIP Ltd 2023
CONTRACT ENQUIRIES
+44 (0)1992 708 316
info@lefroybrooks.co.uk
CUSTOMER SERVICE, SPARES & TECHNICAL ENQUIRIES
+44 (0)1902 390 894
technical@lefroybrooks.co.uk
LEFROYBROOKS.CO.UK
20.065.099E / JUNE 2023
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Lefroy Brooks BL 1550 Installation & Servicing Guide

Type
Installation & Servicing Guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI