ADJ VIZ160 User manual

Category
Floodlights
Type
User manual

This manual is also suitable for

VIZI CMY 16RX
User Instructions
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 2
Introduction .......................................................................................................... 3
Safety Precautions ................................................................................................ 5
Features, General Instructions, & Product Registration ....................................... 6
Handling Precautions & Important Discharge Lamp Warnings……………………7
Mounting .............................................................................................................. 9
Base Layout ....................................................................................................... 11
DMX Setup .......................................................................................................... 12
Control by Universal DMX Controller………………………………………………..15
Gobo and Color Wheels ..................................................................................... 16
DMX Mode Values and Traits ............................................................................. 17
System Menu ..................................................................................................... 26
Error Information ................................................................................................ 35!
Lamp and Fuse Replacement ............................................................................ 36
Cleaning ............................................................................................................. 37
Changing the Gobo ............................................................................................ 38
Trouble Shooting………………………………………………………………………39
Specifications ..................................................................................................... 40
Warranty ............................................................................................................. 41
Optional Accessories ......................................................................................... 42
! !
VIZI CMY 16RX
Table of Contents
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 3
!
©2021 ADJ Products, LLC all rights reserved. Information, specifications, diagrams,
images, and instructions herein are subject to change without notice. ADJ Products, LLC
logo and identifying product names and numbers herein are trademarks of ADJ Products,
LLC. Copyright protection claimed includes all forms and matters of copyrightable
materials and information now allowed by statutory or judicial law or hereinafter granted.
Product names used in this document may be trademarks or registered trademarks of
their respective companies and are hereby acknowledged. All non-ADJ Products, LLC
brands and product names are trademarks or registered trademarks of their respective
companies.
ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for
property, equipment, building, and electrical damages, injuries to any persons, and direct
or indirect economic loss associated with the use or reliance of any information contained
within this document, and/or as a result of thezaimproper, unsafe, insufficient and
negligent assembly, installation, rigging, and operation of this product.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This device uses and can radiate radio frequency
energy and, if not installed and used in accordance with the included instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the
device off and on, the user is encouraged to try to correct the interference by one or more
of the following methods:
Reorient or relocate the device.
Increase the separation between the device and the receiver.
Connect the device to an electrical outlet on a circuit different from which the
radio receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.!
!
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the environment. Please turn off all
electrical products when they are not in use. To avoid power consumption in idle mode,
disconnect all electrical equipment from power when not in use. Thank you!
! !
VIZI CMY 16RX
Introduction
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 4
Overview: The Vizi CMY 16RX is a DMX intelligent, moving head fixture. The Vizi CMY
16RX is a 22/24-channel DMX unit. This fixture is a DMX controlled unit. For best results
use fog or special effects smoke to enhance the beams projections. During the initial
start-up or use of this product a light smoke or smell may arise from the unit. This is a
normal process and is cause by the heat associated with the lamp.
This product is intended to be used by professionally trained personnel only and is
not suitable for private use
Unpacking: Thank you for purchasing the Vizi CMY 16RX by ADJ Products, LLC. Every
Vizi CMY 16RX has been thoroughly tested and has been shipped in perfect operating
condition. Carefully check the shipping carton for damage that may have occurred during
shipping. If the carton appears to be damaged, carefully inspect your fixture for any
damage and be sure all equipment necessary to operate the unit has arrived intact. In the
event damage has been found or parts are missing, please contact our toll free customer
support number for further instructions. Please do not return this unit to your dealer
without contacting customer support first.
CUSTOMER SUPPORT: Contact ADJ Service for any product related service and
support needs. Please visit forums.adj.com with questions, comments or suggestions.
REPLACEMENT PARTS please visit parts.adj.com
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
800-322-6337 | Fax 323-582-2941 | [email protected]
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
+31 45 546 85 60 | Fax +31 45 546 85 96 | suppor[email protected]
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040
323-582-2650 | Fax 323-532-2941 | www.adj.com | [email protected]
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99 | www.adj.eu | [email protected]
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070 | [email protected]
DOCUMENT VERSION
Date
Document Version
Software Version
DMX Channel
Mode
Notes
08/2018
1
1.0
22/24
Initial release
10/2018
1.1
1.1
22/24
Menu update
11/2018
1.2
1.1
22/24
Add static gobo images
11/19/19
1.3
NC
N/C
Updated DMX channel values.
02/23/21
1.4
NC
N/C
Updated Important Lamp Discharge Warnings
VIZI CMY 16RX
Introduction
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 5
Please Read and Understand
This
Manual Completely Before You Attempt
To Install Or Operate This Unit!
To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture.
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet matches that of the required voltage for your unit.
Do not attempt to operate this unit if the power cord has been frayed or broken.
Do not attempt to remove or break off the ground prong from the electrical cord. This
prong is used to reduce the risk of electrical shock and fire in case of an internal
short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable parts
inside.
Never operate this unit when its cover is removed.
Always be sure to mount this unit in an area that will allow proper ventilation. Allow
about 6” (15cm) between this device and a wall.
Do not attempt to operate this unit if it becomes damaged.
This unit is intended for indoor use only; use of this product outdoors voids all
warranties.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or
pinched by items placed upon or against them, paying particular attention to cords
at plugs, convenience receptacles and the point where they exit from the appliance.
The fixture should be cleaned only as recommended by the manufacturer. See page
36 for cleaning details.
This fixture should be situated away from heat sources such as radiators, heat
registers, stoves, or other appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water.
C. The appliance does not appear to operate normally or exhibits a marked change in
performance.
WARNING! CAUTION! FIRE HAZARD! DUE TO THE EXTREME HEAT CAUSED BY THIS
LAMP, THE MINIMUM DISTANCE TO LIGHTED OBJECTS IS 12 METERS (40FT).! !
VIZI CMY 16RX
Safety Precautions
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 6
!
Philips® Platinum 16R Discharge Lamp
Micro-Stepping Motors for Smooth Color and Gobo Transitions
DMX-512 Protocol Compatible (2 DMX Channel Modes: 22 or 24 channels)
3/5-Pin XLR In/Out
Full CMY Color Mixing
Independent Gobo and Color Wheels
2 Separate Gobo Wheels
9 static gobos and 6 static apertures
9 rotating, replaceable gobos
Frost Filter
Strobe Effect
Motorized Focus
Motorized Zoom
540˚ Pan Movement
270˚ Tilt Movement
Pan/Tilt Invert
Pan/Tilt Speed Adjustment
Digital Display for Address and Function Setting
!
To optimize the performance of this product, please read these operating instructions
carefully to become familiarized with the basic operations of this unit. These instructions
contain important safety information regarding the use and maintenance of this unit.
Please keep this manual with the unit, for future reference.
!
!
The Vizi CMY 16RX carries a one-year limited warranty. Please fill out the enclosed
warranty card to validate your purchase. All returned service items whether under
warranty or not, must be freight prepaid and accompany a return authorization (R.A.)
number. The R.A. number must be clearly written on the outside of the return package.
A brief description of the problem as well as the R.A. number must also be written down
on a piece of paper and included in the shipping carton. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. You may obtain a R.A. number
by contacting our customer support team on our toll free customer support number. All
packages returned to the service department not displaying a R.A. number on the outside
of the package will be returned to the shipper at the shippers cost.
VIZI CMY 16RX
Features
VIZI CMY 16RX
General Instructions
VIZI CMY 16RX
Product Registration
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 7
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself, doing so will void your manufactures warranty. In the unlikely event your unit
may require service please contact ADJ Products, LLC. During operation the housing
may become extremely hot. Avoid touching the unit with bare hands while in use. ADJ
will not accept any liability for any resulting damages caused by the non-observance.
This fixture is fitted with a discharge lamp, which is highly susceptible
to damage if improperly handled. Never touch the lamp with your bare
fingers, as the oil from your hands will shorten lamp life. Also, never
move the fixture until the lamps have had ample time to cool.
Remember, lamps are not covered under warranty conditions.
This unit emits intense UV radiation, which is harmful to the eyes and skin. The intense
luminance of the lamp can cause severe damage to the retina. Never operate this unit
without its covers, these covers have been specially designed to shield against UV
radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the
lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce
lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use gas sealed in
a high-pressure environment to emit a brilliant output. Due to the high pressure involved
with the construction of the lamp, the lamp may explode during prolonged extensive use.
This risk is increased with age; added care is encouraged when dealing with older lamps.
Extreme caution should be used when operating this or any fixture fitted with a gas
discharge lamp. Never open this unit while in use.
VERY IMPORTANT: This is for your safety and the life length of the unit. The Philips®
Platinum 16R Discharge lamp has lifetime of 1500 hours. ADJ recommends periodically
checking the lamp running time (see page 27 “Light Hour Use”). When the lamp reaches
the 1500-hour mark, or close to it, we strongly suggest you switch the lamp out.
Replace the lamp following the instructions on pages 35-36. After replacing the lamp you
must clear the LAMP RUNNING TIME (see page 27 “Light Hour Use”).
Warning: DO NOT use this lamp more then 1500 hours. Using the lamp any longer
then the set life could seriously damage your unit.
WARNING! CAUTION! FIRE HAZARD! DUE TO THE EXTREME HEAT CAUSED BY
THIS LAMP, THE MINIMUM DISTANCE TO LIGHTED OBJECTS IS 12 METERS (40FT).
VIZI CMY 16RX
Handling Precautions
VIZI CMY 16RX
Important Discharge Lamp Warnings
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 8
LAMP REPLACEMENT WARNING (Software Version > V1.4)
At 1200 hours, the display shall flash “Replace Lamp Soon” for up to 10 minutes. The
user may press Enter to acknowledge the warning and exit into the main menu for
normal operation.
At 1500 hours, the display shall flash “Replace Lamp Now” for up to 10 minutes. The
user may press Enter to acknowledge the warning and exit into the main menu for
normal operation. The fixture should continue to work normally when the lamp life
reaches its maximum operation hour mark during live use. Once the fixture is powered
OFF and back ON, the fixture display should flash “Replace Lamp Now”.
At 1700 hours, the display shall flash “Replace Lamp Now” and the fixture will no
longer respond to DMX commands and immediately enter a hibernation mode that will
electronically discontinue all fixture functionality with the exception of a few menu
commands. The fixture shall remain in hibernation mode until the lamp is replaced and
the lamp clock has been reset.
The only menu items that the user will have the ability to view or execute are “Fixture
Information” à “Light Use Hour” (in order to view the number of hours on the current
lamp) à “Reset Time” (which must be used after replacing the lamp to reset the lamp
time and regain access to the standard menu options).
VIZI CMY 16RX
Important Discharge Lamp Warnings
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 9
When installing the unit, the trussing or area of installation must be able to hold
10 times the weight without any deformation. When installing the unit must be
secured with a secondary safety attachment, e.g. and appropriate safety cable.
Never stand directly below the unit when mounting, removing, or servicing the
unit. Overhead mounting requires extensive experience, including calculating
working load limits, installation material being used, and periodic safety
inspection of all installation material and unit. If you lack these qualifications, do
not attempt the installation yourself. A skilled person should check the installation
once a year.
The Vizi CMY 16RX is fully operational in three different mounting positions,
hanging upside-down from a ceiling, sideways on trussing, or set on a flat level
surface. Be sure this fixture is kept at least 12m (40ft) away from any flammable
materials (decoration etc.). Always use and install the supplied safety cable as a
safety measure to prevent accidental damage and/or injury in the event the clamp
fails (see next page). Never use the carrying handles for secondary attachment.
VIZI CMY 16RX
Mounting
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 10
NOTICE: The suitable environmental temperature for this lighting fixture is
between -25˚ C to 45˚ C. Do not place this lighting fixture in an environment where
the temperatures are under or above the temperatures stated above. This will
allow the fixture to run at its best and help prolong the fixture life.
Screw one clamp each via a M12 screw and nut onto the Omega holders. Insert
the quick-lock fasteners of the first Omega holder into the respective holes on the
bottom of the Vizi CMY 16RX. Tighten the quick-lock fasteners fully clockwise.
Install the second Omega holder. Pull the safety cable through the openings
located on the base plate and over the trussing system or a safe fixation spot.
Insert the end in the carabineer and tighten the safety screw.
VIZI CMY 16RX
Mounting
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 11
1. USB:
2. LED:
POWER
ON
DMX
ON
3. Display: Shows the selected function or various menus.
4. Button:
MENU
To enter into, move backward or leave the
menu
UP
To go backward or to move up in the menu
DOWN
To go forward or to move down in the menu
ENTER
To perform the desired functions
5. DMX Input/Output: For DMX-512 Operation. Use 3 or 5-pin XLR cable to
link multiple units together.
6. Fuse (T-10A): Protect the unit from damage of over current
7. Power: To connect to the mains supply.
8. Power Switch: Turns On/Off the power.
VIZI CMY 16RX
Base Layout
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 12
Power Supply: The Vizi CMY 16RX contains an electronic ballast, which will auto
sense the voltage when it is plugged into the power source. With the electronic
ballast you do not need to worry about wall voltage, this unit can be plugged in
anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal
pro
tocol used
by most lighting and controller manufactures as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data
instructions from the controller to the fixture. DMX data is sent as serial data that
travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals
located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different
manufactures to be linked together and operate from a single controller, as
long as all fixtures and the controller are DMX compliant. To ensure proper
DMX data transmission, when using several DMX fixtures try to use the
shortest cable path possible. The order in which fixtures are connected in a DMX
line does not influence the DMX addressing. For example, a fixture assigned a
DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at
the end, or anywhere in the middle. Therefore, the first fixture controlled by the
controller could be the last fixture in the chain. When a fixture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address
1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements: The Vizi CMY 16RX can be controlled
via DMX-512 protocol. The Vizi CMY 16RX has two DMX channel modes (22
channel mode and 24 channel mode). The DMX address is set electronically using
the controls on the rear panel of the unit. Your unit and your DMX controller require
an approved DMX-512 110 Ohm Data cable for data input and data output (Figure
1). We recommend AccuCable DMX cables. If you
are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable be
purchased at almost all professional sound and
lighting stores). Your cables should be made with a
male and female XLR connector on either end of the
cable. Also remember that DMX cable must be daisy
chained and cannot be split.
VIZI CMY 16RX
DMX Setup
Figure 1
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 13
Notice: Be sure to follow figures two and three when making your own cables.
Do not use the ground lug on the XLR connector. Do not connect the cable’s
shield conductor to the ground lug or allow the shield conductor to come in
contact with the XLR’s outer casing. Grounding the shield could cause a short
circuit and erratic behavior.
Special Note: Line
Termination:
When longer runs of cable are used, you may
need to use a terminator on the last unit to avoid erratic behavior. A terminator is a
110-120 ohm 1/4 watt resistor, which is connected between pins 2 and 3 of a male
XLR connector (DATA + and DATA -). This unit is inserted in the female XLR
connector of the last unit in your daisy chain to terminate the line. Using a cable
terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
VIZI CMY 16RX
DMX Setup
Figure 4
DMX512 IN
3-PIN XLR
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 14
!
5-Pin
XLR DMX
Connectors:
Some manufactures use 5-pin DMX-512 data cables
for DATA transmission in place of 3-pin. 5-pin DMX fixtures may be implemented
in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a
cable adaptor must be used, these adaptors are readily available at most electric
stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
5-Pin XLR Male (In)
Ground/Shield
Pin 1
Pin 1
Data Compliment
(- signal)
Pin 2
Pin 2
Data True
(+ signal)
Pin 3
Pin 3
Not
Used
Pin
4 - Do
Not
Use
Not
Used
Pin
5 - Do
Not
Use
Universal DMX Control: This function allows you to use a universal DMX-512
controller. A DMX controller allows you to create unique programs tailored to your
individual needs.
1. The Vizi CMY 16RX has a 2 DMX channel modes (22 and 24 channels).
See pages 16-24 for detailed description of the DMX traits.
2. To control your fixture in DMX mode, follow the set-up procedures on
pages 14, 25-27 as well as the set-up specifications that are included with
your DMX controller.
3. Follow the instructions on page 26 to select your desired DMX addr
ess.
4. Use the controllers faders to control the various DMX fixture traits.
5. For longer cable runs (more than a 100 feet) use a terminator on the last
fixture.
6. For help operating in DMX mode consult the manual included with your
DMX controller.
VIZI CMY 16RX
DMX Setup
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 15
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120
ohm 1/4W resistor between pin 2(DMX) and pin 3(DMX+) into a 3pin XLRplug
and plug it in the DMXoutput of the last unit.
2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of
the unit to the input of the next unit. The cable cannot be branched or split to a
“Y” cable. DMX 512 is a very highspeed signal. Inadequate or damaged cables,
soldered joints or corroded connectors can easily
3. When power to one of the units is disconnected, the DMX output and input
connectors are passthrough to maintain the DMX circuit,
4. Each lighting unit needs to have a DMX address to receive the data by the
controller. The address number is between 0511 (usually 0 & 1 are equal to 1).
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 3 pin XLR connectors are more popular than 5 pin XLR connectors.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (), Pin 3: Positive signal (+),
Pin4, Pin5 not used.
VIZI CMY 16RX
Control By Universal DMX Controller
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 16
VIZI CMY 16RX
Gobo and Color Wheels
Color Wheel
DANGER!
Before installing or changing the gobo wheel, make sure the device has been switched off.
Static Gobo Wheel
Rotating Gobo Wheel
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 17
22 Channels:
Channel
Value
Function
1
000 - 255
Pan - 540°
2
000 - 255
Pan Fine
3
000 - 255
Tilt - 270°
4
000 - 255
Tilt Fine
5
000 255
Cyan 0% - 100%
6
000 - 255
Magenta 0% - 100%
7
000 - 255
Yellow 0% - 100%
8
Color
000005
White
006011
Red
012017
Dark Orange
018023
Dark Green
024029
Dark Blue
030035
Pink
036041
Light Purple
042047
Light Green
048053
Light Orange
054059
Cyan
060127
White to Cyan
128189
Clockwise Rotation Fast to Slow
190193
Stop
194255
Counter-Clockwise Rotation Slow To Fast
! !
VIZI CMY 16RX
DMX Mode Values and Traits
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 18
! !
Channel
Value
Function
9
Static Gobo
000002
White
003005
Gobo 1
006008
Gobo 2
009011
Gobo 3
012014
Gobo 4
015017
Gobo 5
018020
Gobo 6
021023
Gobo 7
024026
Gobo 8
027029
Gobo 9
030032
Gobo 10
033035
Gobo 11
036038
Gobo 12
039041
Gobo 13
042044
Gobo 14
045054
Gobo15
055058
Gobo1 Shaking Slow To Fast
059062
Gobo2 Shaking Slow To Fast
063066
Gobo3 Shaking Slow To Fast
067070
Gobo4 Shaking Slow To Fast
071074
Gobo5 Shaking Slow To Fast
075078
Gobo6 Shaking Slow To Fast
079082
Gobo7 Shaking Slow To Fast
083086
Gobo8 Shaking Slow To Fast
087090
Gobo9 Shaking Slow To Fast
091094
Gobo10 Shaking Slow To Fast
095098
Gobo11 Shaking Slow To Fast
099102
Gobo12 Shaking Slow To Fast
103106
Gobo13 Shaking Slow To Fast
107110
Gobo14 Shaking Slow To Fast
111127
Gobo15 Shaking Slow To Fast
128189
Clockwise Rotation Fast to Slow
190193
Stop
194255
CounterClockwise Rotation Slow To
Fast
VIZI CMY 16RX
DMX Mode Values and Traits
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 19
!
!
!
! !
Channel
Value
Function
10
Rotating Gobo
000006
White
007013
Gobo1
014020
Gobo2
021027
Gobo3
028034
Gobo4
035041
Gobo5
042048
Gobo6
049055
Gobo7
056062
Gobo8
063083
Gobo9
084087
Gobo1 Shaking Slow To Fast
088092
Gobo2 Shaking Slow To Fast
093097
Gobo3 Shaking Slow To Fast
098102
Gobo4 Shaking Slow To Fast
103107
Gobo5 Shaking Slow To Fast
108112
Gobo6 Shaking Slow To Fast
113117
Gobo7 Shaking Slow To Fast
118122
Gobo8 Shaking Slow To Fast
123127
Gobo9 Shaking Slow To Fast
128189
Clockwise Rotation Fast to Slow
190193
Stop
194255
CounterClockwise Rotation Slow To Fast
11
Gobo Rotation (updated 11/19/2019)
000 127
Index
128 189
Clockwise Rotation Fast to Slow
190 193
Stop
194 255
Counterclockwise Rotation Slow to Fast
12
Prism 1
000 007
Close
008 255
Open
13
R-Prism 1 (updated 11/19/2019)
000 127
Index
128 190
Clockwise Rotation Fast to Slow
191 192
Stop
193 255
Counter-Clockwise Rotation Slow to Fast
14
Prism 2
000 007
Close
008 255
Open
VIZI CMY 16RX
DMX Mode Values and Traits
ADJ Products, LLC ! ww.adj.com ! VIZI CMY 16RX User Instructions Page 20
!
! !
Channel
Value
Function
15
R-Prism 2 (updated 11/19/2019)
000 127
Index
128 190
Clockwise Rotation Fast to Slow
191 192
Stop
193 255
Counter-Clockwise Rotation Slow to Fast
16
Strobe
000003
Light OFF
004103
Strobe At Linearly Variable Frequency (Low High)
104107
Light ON
108207
Pulsation At Linearly Variable Speed, (Slow Fast)
208212
Light ON
213225
Random Strobe At Low Frequency
226238
Random Strobe At Medium Frequency
239251
Random Strobe At High Frequency
17
Dimmer
000 - 255
0% 100%
18
Focus
000 255
0% 100%
19
Zoom
000 255
0% - 100%
20
Frost
000 007
Close
008 255
Open
21
Pan/Tilt Speed (updated 11/19/2019)
000 254
Fast to Slow
255
Fast
22
Special Function
000 069
No Function
070 079
Blackout While Pan Tilt Move Enable
080 089
Blackout While Pan Tilt Move Disable
090 099
Blackout While Color Move Enable
100 109
Blackout While Color Move Disable
110 119
Blackout While Gobo Move Enable
120 129
Blackout While Gobo Move Disable
130 139
Lamp On
140 149
Reset XY
150 159
Reset Effect
160 199
No Function
200 209
Reset All
210 230
No Function
231 239
Lamp Off
240 255
No Function
VIZI CMY 16RX
DMX Mode Values and Traits
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

ADJ VIZ160 User manual

Category
Floodlights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document