Tektronix P7708 User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

x
P7700 Series
TriModeā„¢ Probes
ZZZ
User Manual
*P071342102*
071-3421-02
P7700 Series
TriModeā„¢ Probes
ZZZ
User Manual
xx
www.tek.com
071-3421-02
Copyright Ā© Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidia ries or suppliers, and are protected by
national copyright laws and international treaty provisions.
Tektronix products are cove red by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously
published material. Speciļ¬cations and price change privileges reserved .
TEKTRONIX and TEK a re registered trademarks of Tektronix, Inc.
TriMode and TekFlex are both trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tek.com to ļ¬nd contacts in your are a.
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period o f one (1) year from the date of shipm ent. If
any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts
and labor, or will provide a replacement in exchange for the defective product. Parts , mo dules and rep lacement products used by Tektro nix fo r
warranty work may be new or reconditioned to like new performance. All replaced parts, m odules and products become the property of Tektronix.
In order to obtain service under this warranty, Custom er must notify Tektronix of the defect before the expiration of the warranty period and make
suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defect ive product to the service
center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a
location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties,
taxes, and any other charges for products returned to any other locations.
This warra nty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix
shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel o ther than Tektronix
representatives to install, repair or service the produ ct; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to
repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modiļ¬ed or integrated with
other products when the effect of such modiļ¬cation or integration increases the tim e or difļ¬culty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR F ITNESS F OR A PARTICULAR
PURPOSE. TEKTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY
PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY
INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER T EKTRONIX OR THE VENDOR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
[W2 ā€“ 15AUG04]
Table of Contents
Table of Contents
Important safety information................................................................................................................ iii
General safety summary . ............................................................................................................. iii
Terms in this manual ... ............................................................................................................... iv
Symbols and terms on the product.................................................................................................... v
Compliance information .................................................................................................................... vi
Environmental considerations ........................................................................................................ vi
Preface..................................................................................................................................... vii
Probe models ........................................................................................................................ vii
Documentation....................................................................................................................... vii
Key features ................................................................................................................................ 1
Operating considerations................................................................................................................... 2
Installation .................................................................................................................................. 4
Overview .............................................................................................................................. 4
Connect to the host instrument ....................................................................................................... 5
Connect P770 0 accessories to the TekFlex connector . ............................................................................. 7
Probe comp box controls and indicators ............................................................................................. 8
Functional check and calibration.......................................................................................................... 11
Functional check..................................................................................................................... 11
TriMode probe DC calibration .......................................................................................................18
P7700 Series TriMode Pro bes User Manual i
Table of Co ntents
Basic operation ............................................................................................................................ 24
Probe setup screen.................................................................................................................. 28
Improving measurement accuracy .................................................................................................. 36
Connecting to a circuit b oard .. ...................................................................................................... 45
Probe handling best practices............................................................................................................. 64
S-parameter information................................................................................................................... 66
Accessories and options .................................................................................................................. 67
Standard accessories.. .............................................................................................................. 67
Optional accessories................................................................................................................. 70
Maintenance............................................................................................................................... 74
Host instrument ļ¬rmware ............................................................................................................ 74
Browser tip replacement............................................................................................................. 75
Error conditions ...................................................................................................................... 76
Handling the probe................................................................................................................... 79
Cleaning the probe................................................................................................................... 80
Returning the probe for servicing.................................................................................................... 81
Index
ii P7700 Series TriMode Probes User Manual
Important safety information
Important safety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product
in a safe condition.
General safety summary
Use the product only as speciļ¬ed. Review the following safety precautions to avoid injury and pre vent damag e to this product or
any products connected to it. Carefully read all instructions. Retain these instructions for fu ture reference.
This product is not intended for detection of hazardous voltages.
Observe all terminal ratings. To avoid ļ¬re or shock hazard, observe all ratings and markings on the product. Consult the
product manual for furt her ratings information before making connections to the product.
Do not apply a potential to any terminal, including the common terminal, tha t exceeds the maximum rating of that terminal.
Do not operate without covers. Do not operate this product with covers or panels removed, or with the case o pen. Hazardous
voltage exposure is possible.
Avoid exposed circuitry. Do not touch exposed connections and components when powe r is present.
Do not operate in wet/damp conditions . Be aware that condensation may occur if a unit is moved from a cold to a warm
environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Remove the input signals before you clean the pro duct.
P7700 Series TriMode Pro bes User Manual iii
Important safety information
Probes and test leads
Remove all pro bes, test leads and accessories that are not in use.
Inspect the probe and accessories. Before each use, inspect probe an d accessories for damage (cuts, tears, or defects in the
probe body, accessories, or cable jacket). Do not use if damaged.
Useonspeciļ¬ed rep lacem ent parts.
Termsinthismanual
These terms may appear in this manual:
WARNING. Warning statemen ts identify conditions or practice s that could result in injury or loss of life.
CAUTION. Caution sta tements identify conditions or practices that could result in dama ge to this product or other property.
iv P7700 Series TriMode Probes User Manual
Important safety information
Symbols and terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product .
When this symbol is marked on the product , be sure to co nsult the manual to ļ¬nd out the nature of the potential
hazards and an y actions which have to be taken to avoid them. (This symbol may also be used to refer the
user to ratings in the manual.)
The following symbol(s) may appear on the produ ct :
P7700 Series TriMode Pro bes User Manual v
Compliance information
Compliance information
This section lists the environmental standards with which the instrument complies.
Environmental considerations
This section provides information about the environmental impact of the product.
Product end-of-life handling
Observe the following guide lines when recycling an instrument or component:
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment m ay
contain substances that could b e harmful to the environment or human h ealth if improperly handled at the productā€™s end of life. To
avoid release of such su bstances into the environment and to reduce the use of natural resources, we encourage you to recycle this
product in an appropriate system th at will ensure that most of the m aterials are reused or re cycled appropriately.
This symbol indicates that this product complies with the app licable European Union requirements according to
Directives 2012 /19/EU and 2006/66/EC on waste electrical an d electronic equipment (WEEE) and batteries. For
information about recycling options, ch eck the Tektronix Web site (www.tek.com/productrecycling).
vi P7700 Series TriMode Pro bes User Manual
Preface
Preface
This manual describes the installation and operation of the P7700 Series TriMode Probes. Basic probe operations and concepts
are presen ted in this manual. All documents listed below are accessible from the Tektronix Web site (www.tek.com/manuals).
Probe models
These P7700 Series TriMode Probe family includes these mode ls:
P7708 8 GHz
P7713 13 GHz
P7716 16 GHz
P7720 20 GHz
Documentation
To read about Use these docu ments
Installation and Operation (overviews) Read this manual for information about how to set up and use your probe .
In-Depth Operation Use the technical reference manual and this manual.
Speciļ¬cations Use the technical refere nce manual.
Reordering accessories
Use the Accessories and Options section or refer to the insert in your
accessory kit when reordering accessories.
P7700 Series TriMode Pro bes User Manual vii
Preface
viii P7700 Series TriMode Probes User Manual
Key features
Key features
The P 7700 Se ries TriMode Probes allow yo u to take differential, single-ended, and common mode measurements with one probe
connection. Key features include:
Low loading for low power circuits
Thin solder-in t ips that can ļ¬tintotight
spaces on a device under test
Flexible solder-in tips and main probe cable
Lightweight probe cable and hea d
TekFlexā„¢ connector technology that
makes the pro be easy to connect to
accessories
Optional 2.92 mm adapter for connecting
to 50 ā„¦ RF test points
Browser accessory with adjustable tips and
headlight
Full AC calibration of the probe and
accessory tips with unique S-parameters
Solder-in tips operate at extended
temperature range
P7700 Series TriMode Pro bes User Manual 1
Operating considerations
Operating considerations
Table 1: P7700 Series TriMode probes
Characteristic Description Speciļ¬cation
TekFlex solder-in
tips
P77BRWSR P77C292MM adapte r
Input Voltage Dynamic range
2.5 Vpp (single-
ended)
5.0 Vpp (differential
input)
6.0 Vpp (single-
ended)
12.0 Vpp (differential
input)
1.2 Vpp (single-
ended)
2.0 Vpp (d ifferential
input)
Operating voltage
window
Ā±5.25 V Ā±10.0 V Ā±4.0 V
Offset voltage range
-4 V to +4 V -10 V to +10 V - 4 V to +4 V
Maximum non-
destructive input
voltage
-15 V to +15 V (tip attached or d etached )
-5Vto+5V
Probe compensation box: 0 Ā°C to 45 Ā°C (32 Ā°F to 113 Ā°F )Operating
Probe cable, solder tips, and P77292MM adapter: -35 Ā°C to 8 5 Ā°C (-31 Ā°F to
185 Ā°F); Minimum Airļ¬‚ow required 46Ā°C to 85Ā°C (114.8 Ā°F to 185 Ā°F)
Probe compensation box: -2 0 Ā°C to 60 Ā°Cg (-4 Ā°F to 140 Ā° F)
Temperature
Non-operating
Probe cable, solder tips, and P77292MM adapter: -35 Ā°C to 8 5 Ā°C (-31 Ā°F to
185 Ā°F)
2 P7700 Series TriMode Probes User Manual
Operating considerations
Characteristic Description Speciļ¬cation
TekFlex so lder-in
tips
P77BRWSR P77C292MM adapter
Operating Probe Compensation Box, Cable, Tips, and SM A adapter: 20% to 80%
Relative Humidity (%RH) at up to 45Ā°C non-condensing
Humidity
Non-operating
Probe Compensation Box, Cable, Tips, and P 77292MM adapter: 10% to 90%
(Relative Humidity), non-condensing
Altitude Non-operating
Probe Compensation Box, Cable, Tips, and S MA adapter: 12,000 meters
(39,370 feet)
Pollution Degree 2, Indoor use only
CAUTION. To avoid ESD damage to t he probe, always use an antistat ic wrist strap (provided with your probe), and work at
a static-approved workstation when you ha ndle the probe.
P7700 Series TriMode Pro bes User Manual 3
Installation
Installation
Before you connect the probe to your instrument, read the Overview below to understand t he sequ ence o f events necessary to
properly install the probe and adapters.
CAUTION. To avoid ESD damage to the probe, always use an ant istatic wrist strap (provided with your probe), and work at
a static-approved workstation when you handle the probe.
Overview
1. Connect the probe to the host ins trument.
If it is the ļ¬rst time the probe has been connected to the oscilloscope, the oscilloscope will download the S-parameters stored in
the probe. Once the oscilloscope has s tored the S-parameters for the probe, it doesnā€™t matter which cha nnel the probe is
plugged into. The stored S-parameters will be available for any chan nel the probe is moved to.
2. Connect the probe tip to the TekF lex connector on the probe.
When a tip is inserted into the probe for the ļ¬rst time, the oscilloscope will download the S-pa rameter data stored in the tip.
3. The p
robe performs a s elf test, and then one Input Mode LED remains on.
4. Open the Calibration menu (found in the Vertical menu).
5. Perform the DC probe calibration procedure using the DC probe cal ļ¬xture that ships standard w ith each probe. (See page 18,
TriMode probe DC calibration.)
6. Use the Probe Setup screen to set the probe parameters as described in the Basic Operation section.
4 P7700 Series TriMode Probes User Manual
Installation
Connect to the host instrument
NOTE. Your TekCo nnect instrument may
require a ļ¬rmware upgrade to support full
functionality of the P7 700 Series probes.
Before you connect the probe , check the
version requirements. (See page 74, Host
instrument ļ¬rmware.)
1. Slide the probe into the TekConnect
receptacle. The probe clicks into place
when fully engaged.
2. Optional. Turn the thumbscrew clockwise
(ļ¬nger-tight only) to secure the probe to
the instrument.
Disconnect
3. To disconnect, turn t he thu mbscrew
counter-clockwise.
4. Press the latch release button and pull the
probe away from the instrument.
P7700 Series TriMode Pro bes User Manual 5
Installation
Probe and probe tip power-on
After the connection to the oscilloscope is
made:
1. The probe brieļ¬‚y turns on all LEDs during
a self-test, and then the A ā€“ B Input Mode
LED remains on. If a probe tip is attached,
an LED on the tip also turns on when
properly attached to the probe.
2. The probe transfers dat a from the probe
and tip to the host instrume nt, and a
message displays on the instrument as the
transfer occurs.
The data transfer takes a few minutes,
and is only done when the host instrument
discovers a new probe or new p robe
tip. The data transfer only occurs on
instruments that are fully compatible with
the probe.
3. After the data transfer is done, the probe is ready f or a fun c tional check and calibration. (See page 11, Functional check.)
NOTE. If the probeā€™s warning light remains on, the po wer-on self-test likely failed.
(See page 76, Error conditions.)
6 P7700 Series TriMode Probes User Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98

Tektronix P7708 User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI