Acroprint ATRx Biometric 1000 Quick start guide

  • Hello! I am an AI chatbot trained to assist you with the Acroprint ATRx Biometric 1000 Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Beforeyouproceed,letsmakesure
youhaveeverythingyouneedfora
successfulinstallation.
ATRxBiometric1000
QuickStart
www.acroprint.com
TakeInventory
1
6
LetsGetConnected
4
GettingStarted
5
Activatethe
HandPunch1000to
PCCommunications
6a
Activatethe
HandPunch1000to
PCCommunications
6b
6c
EnrollingEmployeefor
PunchConfirmation
7a
Ifyouhavecompletedallofstepslistedabove,
thenyouarereadytoloadthesoftware.
1. ConfirmAttendance Rxsoftwareis
runningbyverifyingthesystemtrayicon
appearsinthebottomright-handcorner
ofyourcomputerdesktopwindownext
totheWindowsPCclock.
2.ToenabletheHP1000,youmustrightclickonthe
SystemTrayandselectSystemUtilitiesfrom
themenubyleftclickingonetimeontheitem.
3.EntertheAdministrativepasswordyoucreated
duringtheinstallationandsetupprocessintothe
passwordfield.
Hardware:IBMPCCompatibleComputer,Intel
PentiumII400mhzorhigher,128MBRAM,150MB
FreeSpaceonHD,CD-RomDrive,Atleast256
SVGAvideo,Minimum800x600resolution
Software:Microsoft® Windows98SE,Windows
2000Professional,WindowsXPProfessional,
WindowsXPHome,Windows2003Server
ContentsfortheATRxBiometric1000:
ATRxBiometricEnabled
softwareCD
HP1000
CommunicationCable
PowerTransformer
MinimumSystemRequirements:
Installing theHandPunch
2
AccessingtheSoftware
UserManual
3
FIRST,TURNOFFYOURPC!
1. ToavoiddamagetothePCport,PCpower
mustbecompletelyshutdownpriorto
attachingtheHP1000communicationcable.
2. Connecttheserialconnectorofthe
communicationcabletoaserialportonthe
backofyourPC.
3. Connecttheotherendofthecommunication
cabletotheRS232portonthebackof
HP1000.
You canaccesstheusermanualintwoways:
A.ClickontheHelpmenuintheAdministrator
sectionofthesoftware.Searchforinformation
bytopic.
B.Gotohttp://www.acroprint.com/
acroprintstore/solutions/user-manuals.aspxto
downloadacompletemanualfromourwebsite.The
usermanualisofferedinPDFformat,whichrequires
AdobeAcrobatReadertoview.
Thequickstartsheetreviewstheinstallation
ofsoftwareandtheconnectionofthe
HandPunchtoyourPC.Forinstructionson
preparingtheHandPunchforwallmounting,
routingofwiring,andwiringconnections,
pleaserefertotheusermanualonpages
15-21.Besuretotestandenrollthe
employeespriortomountingtheHandpunch.
1. InstallATRxBiometricallyEnabledSoftware
byinsertingtheCDintotheCD-ROMdrive
andcompletetheinstallationwizard.
2. SelectRestartthePCattheendofthe
softwareinstallation.
3. Followtheon-screenSetupWizardenteringin
yourcompanyinformation,suchaspayperiod
type,overtimerules,andshiftsettings.You
willbepromptedtoenteryouremployee
informationatthistime.
IfyoudoNOTcompletetheSetupWizardthe
programwillnotrunsuccessfully.
Pleasewritedownyouradministrativepassword
andstoreinasafeplace.Youwillbeprompted
toenterthepasswordinStep6bofthisquick
startguide.
NOTE
NOTE
Activatethe
HandPunch1000to
PCCommunications
4.SelectthesecondtablabeledBiometricsinthe
SystemsUtilitiesscreen.
5.PlaceacheckintheEnableAttendanceRx
BiometricFunctionalityboxbyleftclicking
onetimeinthecheckboxfield.
6.UnderthetextInstallBiometricsDevice,left
clickonetimeonthedropdownmenuand
selecttheIRHandPunch1000(DEV-2).
7.SelectYESontheEnableTerminalManager
windowtostarttheTerminalManager
automatically.
8.ClosetheSystemsUtiliteswindowbyleft
clickingonetimeontheClosebutton.
NOTE
Employees must have a PIN assigned before enrolling.
1. FromyourdesktopopentheAttendanceRx
Administratorbydoubleclickingonthedesktop
iconlabeledAdministrator.
2. Enteryourpasswordinthespaceprovided.
3. LeftclickonetimeontheEmployeebutton
locatedontheNavigationBartotheleft.
ATRxBiometric1000
QuickStart
www.acroprint.com
7b
EnrollingEmployeefor
PunchConfirmation
7c
EnrollingEmployeefor
PunchConfirmation
7d
8
5640DepartureDrive
Raleigh,NC27616
1-800-334-7190
www .acroprint.com
PN:06-0326-000Rev.A
4. Selectanemployeerecordfromthelistbyleft
clickingonetimeontheLastNamefield.
5. LeftclickonetimeontheEnrollHandbutton
atthebottomofthescreen.
6. LeftclickonetimeontheEnrollEmployee
button.
7. SelectYestothemessageEnrollforPINand
theemployeePINdisplayed.
8. Messageaboutenrollingyourhandprintwill
display.Followtheon-screeninstructions
placingtheemployeeshandinthehand
punch3times.
EnrollingEmployeefor
PunchConfirmation
Successfulenrollmentofhandwilldisplay:
9. SelectOK.
10. SelectSaveontheemployeeHand
Punchwindow.
NOTE
Whenyouremployeeshavebeen
successfullyenrolledinthesoftwareand
HP1000theyarereadytoclockin/out.
1. EmployeeentersassignedPIN
numberonthekeypadofHP1000.
2. PressEnter.(redplacementlightswill
display).
3. PlacerighthandintotheHP1000as
shownonthefrontpanelofthehand
punch.
4. Agreenlightwilldisplaywitha
messageconfirmingOkayanda
ReadScoretolettheemployeesknow
theirpunchwasgood.*
*AReadScorereflectshowaccuratelythe
employeeisplacingtheirhandintheHP1000.
Scorewillvarygreatly.Scoresabove50
indicateincorrecthandplacement.
HowToforEmployees;
UsingtheHandpunch1000
TroubleShootingtheHP1000
Repeatthisprocessasneededtocontinue
enrollingemployees.Alsoperformthis
processfornewhires.
11. Aftercompletingthisprocess,select
SaveintheEmployeerecordmainwindow.
EmployeesmaybeginusingtheHP1000
immediatelyaftersuccessfulenrollment.
Forinstructionsonpreparingthe
HandPunchforwallmounting,routingof
wiring,andwiringconnections,please
refertotheusermanualonpages15-21.
Besuretotestandenrolltheemployees
priortomountingtheHandpunch.
TocontacttheAcroprintSupportDepartment:
Web: support.acroprint.com
Phone:1-800-334-7190option3
Fax: 919-872-5967
IamtryingtoenrollmyemployeeshandsanddonotseetheEnrollHandbuttononthe
employee screen.
ChecktoconfirmHP1000biometricdevicehasbeenenabledinthesoftware.
Pleaserefertosteps6a,6band6c.
IamtryingtoenrollmyemployeeshandintheHP1000andthefollowingmessagedisplays:
AttendanceRxisunabletocommunicatewiththeHandPunch1000reader,pleasemake
certainthedeviceisproperlyconnected.
Areyouusingthecommunicationscableandadapterthatcamewiththe
ATRxBiometric1000package?ThiscableandadapterisspecificallywiredforPC
toHP1000RS232communication.
IsthecommunicationcableandadaptersecureonthePCserialportandintheback
oftheHP1000?
IsthepowertransformerfortheHP1000pluggedintoafunctionalwalloutlet?
IsthecommunicationcableandadapterattachedtoafunctionalPCserialport?
ConfirmyourPChasavailablefunctionalserialcommunicationports.(Contactthemanufacturerofyour
computerequipmentforassistance).ManynewerPCmodelscomestandardwithoneserialportandmany
USBports.MostPCshaveaninternalmodeminstalled.Itiscommonforamodemtobeassignedtoa
virtualcommunicationsport,whichmaybeusingthesameIRQasthephysicalserialcommunicationsport
youhavetheHP1000pluggedinto.EachserialporthasanIRQ(InterruptRequest)value.Thatvalue
allowsadevicesuchasamodem,aprinter,aHP1000tointerrupttheprocessesofyourcomputertosend
andreceiveasignaltoperformanothertask.YourprinterusesanIRQtosendamessagetothecomputer
toprint.Whenaprinterhasfinishedprinting,itsendsaninterruptsignaltothecomputerthatinterruptsthe
computersothatitcandecidewhatprocesstodonext.Multiplesignalstothecomputerusingthesame
interruptvaluecancauseoneormoredevicestoNOTfunctionasexpected.Toavoidthisproblemeach
devicemusthaveauniqueIRQ.
IstheHP1000exposedtoexcessiveairbornedust?
AvoidmountingtheHandpunchindirectsunlightorinareaswithexcessivedust.
DoNOTspraycleaningchemicalsdirectlyonHP1000.Useacleanclothwithalight
sprayofsolutiontocleantheHP1000.
Dramaticweightgainorlossmaypreventemployeefromusingthehandpunchuntilhe
orsheisre-enrolled inthesoftware.PleaseseeSteps7a-7dtoEnrollingEmployeefor
PunchConfirmation.
Deepormultiplecutsonhandcancausepunchfailure.
Foreignobjectsonhandsuchasband-aidsandorbandagesmaycausepunchfailure.
NOTE
NOTE:This equipmenthas beentested andfound tocomplywiththe
limits for a Class Bdigital device, pursuant to Part 15 ofthe FCC
Rules.Theselimitsaredesignedtoprovidereasonableprotection
againstharmful interferencein aresidentialinstallation. This
equipmentgenerates, usesandcanradiateradio frequencyenergy
and,ifnot installed and usedinaccordancewith the instructions, may
cause harmful interference to radio communications. However, there
isnoguaranteethatinterferencewillnotoccurinaparticular
installation.Ifthisequipmentdoescauseharmfulinterferencetoradio
ortelevision reception,which canbe determinedby turningthe
equipmentoffandon,theuserisencouragedtotrytocorrectthe
interferencebyoneormore of the following measures: Reorientor
relocatethereceivingantenna;Increasetheseparationbetweenthe
equipmentandreceiver;Connecttheequipmentintoanoutletona
circuit different from that to which the receiver is connected; Consult
thedealeroranexperiencedradio/TVtechnicianforhelp.
/