12
Technical catalog for Susol & Metasol ACB
Technical catalog for Susol & Metasol ACB
A
AN N16D H
OCR TYPE
0
N
OCR Not Provided
NORMAL
N
Type Name
LS ACB CRADLE
Rated current & FRAMESIZE
3
No. of pole
3
4
3 poles
4 poles
AN-06-16D
AS-06-16D
AH-06-16D
AS-200 AH-200
AN-06-32E
AS-06-32E
AH-06-32E
AS-40E AH-40E
AS-50F
AS-40-50G
AH-40-50G
E
Safety shutter
E
F
No shutter
Shutter
J
Installation
J
A
No automatic connection
Automatic connection
N
Arc cover
N
S
No ARC COVER
ARC COVER
Installation
Control power supply & Frequency
0
0
5
-
No control power supply, 60Hz
No control power supply, 50Hz
O
H
V
M
N
P
L
N16D
S16D
H16D
H20D
N32E
S32E
H32E
H40E
S50F
S50G
H50G
Top / Bottom horizontal Type
(H20D Not available)
Top / Bottom vertical type
Top horizontal / Bottom vertical type
(H20D Not available)
Top vertical / Bottom horizontal type
(H20D Not available)
Top / Bottom horizontal Type
(40E, 50FG, 63G Not available)
Separate order
Installation on user’s side
G
O
G
-
No communication
Ground fault detection (internal CT Vector Sum)
No. L, S, I, G output terminal (Available to check OC
Ground fault detection (internal CT Vector Sum)
Unable to communicate without control power supply (Available to check OCR LED)
No. L, S, I, G output contact without control power supply (Available to check OCR LED)
N0 AG0, AG5, AZ0, AZ5, AE0, AE5 output contact
A
OCR TYPE
A
Ammeter
O
Control power supply & Frequency
0
1
2
5
6
7
No control power supply, 60Hz
AC/DC 110V~220V, 60Hz
DC 24V~48V, 60Hz
No control power supply, 50Hz
AC/DC 110V~220V, 50Hz
DC 24V~48V, 50Hz
G
Communication & Ground fault detection
G
Z
E
C
K
X
No communication
No communication + Ground fault detection
No communication + External CT Ground fault
Communication
No communication + Ground fault detection
No communication + External CT Ground fault
Ground fault detection (internal CT Vector Sum)
Communication (Not available without control power supply
Application to protect motor
Ground fault detection
Communication (Not available without control power supply
Not applicable for METASOL(AN, AS)
Applicable to protect motor
P
OCR TYPE
P
Power meter
S
OCR TYPE
S
Supreme meter
1
Control power supply & Frequency
1
2
6
7
AC/DC 110V~220V, 60Hz
DC 24V~48V, 60Hz
AC/DC 110V~220V, 50Hz
DC 24V~48V, 50Hz
1
Control power supply & Frequency
1
2
6
7
AC/DC 110V~220V, 60Hz
DC 24V~48V, 60Hz
AC/DC 110V~220V, 50Hz
DC 24V~48V, 50Hz
C
Communication & Ground fault detection
C
K
X
A
Communication
Communication + Ground fault detection
Communication + External CT Ground fault
Communication + Pre-Trip Alam
C
Communication & Ground fault detection
C
K
X
A
Communication
Communication + Ground fault detection
Communication + External CT Ground fault
Communication + Pre-Trip Alam
Communication & Ground fault detection
OCR
Cradle