IKEA HOB 448 S Program Chart

  • Hello! I am an AI chatbot trained to assist you with the IKEA HOB 448 S Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
N C
M Y
PRODUCT DESCRIPTION SHEETHOB 448 ES IT GB
82547 GB 5
1. Removable panstand grids
2. Small burner
3-4. Large burners
5-6. Medium burners
7. Small burner control knob
8. Large burner control knob
9. Large crown burner control
knob
10. Medium burner control
knob
11. Medium burner control
knob
Symbols
Shaded circle
x
Tap closed
Large
Maximum opening/
flame delivery and electric
and star ignition
Small
Minimum opening
flame or reduced delivery
Operation of burners with
safety device and electric
ignition
To light one of the burners:
x Press the relative knob and turn it anti-
clockwise to the large flame and star
setting
.
x Atthesametime,keeptheknobpressed
against the control panel until the burner
ignites.
x After the burner has ignited, keep the knob
pressed for about 10 seconds.
x Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note
Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting
.
The safety device of the burner shuts off the
gas supply to the burner if its flame goes
out accidentally (because of a sudden gust
ofwind,aninterruptioninthegasdelivery,
the overflowing of liquids, etc,).
!§ $ %
" &/()=Q
5019 100 82547
N C
M Y
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: If the distance “A” between the wall cabinets is between 600 mm. and 680 mm. the
height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is
greater than the width of the Cooktop, the height “B” must be a minimum of 400 mm.
INJECTORS TABLE CATEGORY II 2H 3+
Type of gas Type of Injector Rated heat Rated Reduced
used burner marking capacity consump- heat
Gas pressure
tion capacity
Pcs-kW Pcs-kW min. rat. max.
NATURAL large 130 3,00 286 l/h 0,80
GAS medium 105 1,75 167 l/h 0,50 17 20 25
(Methane) G 20 small 83 1,00 95 l/h 0,50
LIQUID large 85 3,00 218 g/h 0,80
PETROLEUM GAS medium 65 1,75 127 g/h 0,50 20 28-30 35
(Cylinder) G 30 small 50 1,00 73 g/h 0,50
LIQUID large 85 3,00 214 g/h 0,80
PETROLEUM GAS medium 65 1,75 125 g/h 0,50 25 37 45
(Cylinder) G 31 small 50 1,00 71 g/h 0,50
Type of gas Appliance Total rated Total rated Air required
used model heat capacity consumption for burning
Pcs-kW m
3
/h
G20 20 mbar 5 gas 10,5 1000 l/h 21
G30 28-30 mbar 5 gas 10,5 764 g/h 21
G31 37 mbar 5 gas 10,5 750 g/h 21
82547 GB 6
/