Murphy OPLH User manual

Type
User manual

This manual is also suitable for

OPLH-94122B page 1 of 4
OPLH / OPLHACS Series
Combination Level Indicating Gage and
Critical Level Limit Switch
High and Low Level Limit Contacts Are
Visible and Adjustable
Designed to Start and Stop Pumps to
Maintain Specific Levels
Indication only Murphygage
®
instrument
Available
Latching Control Relay Versions Available
Description
The OPLHC/OPLHACS Series Level
Swichgage instruments are combination
level indicating gages with adjustable low
and high limit switches. Limit switches can
be wired directly to electric pilot circuits to
operate alarms, shutdown or start/stop
pumps to maintain predetermined levels.
Surface mount or panel mount enclosure is
available for both model series. All models
feature a 4-1/2 in. (114 mm) dial for easy
viewing. Adjustable limit switches are
accessible from front of the Swichgage
instrument.
Specialized models are available for specific
applications involving engines or electric
motors.
OPLHC/OPLHACS
Series Swichgage instruments
include 2-adjustable, pilot duty, pointer type
contacts. Contacts have self-cleaning motion
to enhance electrical continuity. Models are
available with a rugged bourdon-tube or 316
stainless steel bellows sensing element for
greater accuracy and sensitivity in lower
ranges.
A “freeze-proof” sensor of 316 stainless steel
with Buna-N rolling diaphragm, is available.
The “freeze-proof” sensor (OPLHAFP)
inserts approx., 2 in. (52 mm) inside a tank.
OPLHBP/OPLHABPS
Internal latching control relays are available
to provide ON/OFF automation for electric
motor applications.
OPLHC and OPLHACS series are avail-
able in indication only Murphygage models
(OPLHAGS). See Page 2 to determine the
model for your application.
Applications
Saltwater Disposal Systems
Waterflood Systems
Diesel Day Tanks
Oil Storage Tanks
Basic Operation
The OPLHC/OPLHACS series operate from
static head pressure. Pressure is transmitted
to the process connection of the Swichgage
instrument.
From here the pressure flexes the bourdon
tube or operates the 316 stainless steel bel-
lows (depending on which model you have).
The bourdon tube/bellows oper-
ates the stainless
steel rotary
geared movement
which in turn operates
the indicating pointer on
the face of the dial. When
the pointer (A) closes with the
limit contact (B), a control circuit
(C) is completed and signals an alarm and/or
shutdown or starts/stops a pump.
Warranty
A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm
R
Selected configurations
are third party listed. Consult
FWMurphy for details.
OPLHFC
OPLHACS
A
Adjustment
Knob
B
C
OPLH-94122B
Revised 03-06
Catalog Section 15
4-1/2 in. (114 mm) Dial
Level Swichgage
®
instrument
OPLH-94122B page 2 of 4
(1)
Bourdon tube (OPLHC) models in the 20 ft. (6 m) range have an accuracy of 3% full scale.
(2)
ES option available for the 20 ft. (6 m) range models and above.
NOTES:
Options may not be available in combination. Consult factory.
Over range is not to exceed 10% FS above full range.
Calibration is for water. Specify for other liquids.
Add TOTAL height of liquid above the pressure connection to determine correct range (dial scale).
For elevated tanks substract the tank elevation from gage reading to determine actual tank level.
OPLH / OPLHA Series
OPLHC
OPLHFC
OPLHCE
OPLHACS
OPLHACES
OPLHBP
OPLHABPS
OPLHBPE
OPLHABPES
OPLHG
OPLHFG
OPLHAGS
OPLHAGES
OPLHAFCS
OPLHAFGS
Enclosure Type (die cast aluminum)
• Surface mount, square case
• Panel mount, round case
• Panel mount, square case
Limit Switch Ratings
• Pointer Contacts:
SPDT center off; 2 A, 30 VDC, 1 A, 125 VAC.
Latching Control Relay
• SPDT,10 A @ 120 VAC (standard)
• DPDT, 12 VDC (Optional)
• DPDT, 24 VAC (Optional)
• DPDT, 24 VDC (Optional)
Sensing Element
• Bourdon Tube, Bronze/Brass (standard)
• Bellows, 316 Stainless Steel (standard)
Process Connections
• 1/4 NPT Male
• 1/4 NPT Female
• 2 NPT Male
Geared Movement: 300 series stainless steel.
Accuracy (standard calibration is for water)
±2% first/last quarters of scale, 1% middle half scale.
(1)
• 3% full scale.
OPTIONS AVAILABLE (specify when ordering)
• Environment sealed for isolation from the elements (ES).
(2)
• Explosion-proof case; Class I, Div. 2, Groups C & D (EX)
• Explosion-proof less case; internal gage
mechanism without case (EL)
• Less case; internal gage mechanism without case (LC)
• Tickler contact (TA)
RANGES AVAILABLE (specify when ordering)
• 0–5 ft. (0–1.5 m) dual scale dial
• 0–10 ft. (0–3 m) dual scale dial
• 0–20 ft. (0–6 m) dual scale dial
• 0–30 ft. (0–9 m) dual scale dial
• 0–60 ft. (0–18 m) dual scale dial
• 0–120 ft. single scale dial
• 0–3.6 metres single scale dial
• 0–4 metres single scale dial
• 0–6 metres single scale dial
• 0–9 metres single scale dial
Specifications
Shipping Dimensions
Item Dimensions: 16 x 11 x 5-1/2 in. (406 x 279 x 140 mm).
Explosion-proof models:
12 x 12 x 9 in. (305 x 305 x 229 mm).
Shipping Weights
Item Weight: 8 lb. (3.6 kg) approximately.
Explosion-proof models: 22 lb. (10 kg) approximately.
OPLH-94122B page 3 of 4
8 in.
(203 mm)
6-25/64 in.
(162 mm)
8 in.
(203 mm)
Rear mounting holes
for surface mounting
3/8-16 UNC-2B
7/8 in. (22 mm)
deep, 4 places.
Removable lid
to access adjustable
contact knobs.
6-3/4 in.
(171 mm)
6-3/4 in.
(171 mm)
Mounting Hole
7-35/64 in. (192 mm)
diameter. Not required
for surface mounting.
1/2 NPT
optional
rear or side
conduit
3/8-16 UNC-2B
7/8 in. (22 mm)
deep, 4 places.
Process Connection
1/4 NPT Female
Explosion-proof Enclosure (“EX” Option)
8-7/16 in.
(214 mm)
3-3/8 in.
(86 mm)
7-7/8 in.
(200 mm)
3-15/16 in.
(100 mm)
4-1/32 in.
(102 mm)
Mounting Holes
9/32 in. (7 mm)
diameter 3 places.
Not available on
panel mount
square case.
1/2 NPT
conduit
Process Connection
1/4 NPT male on
bourdon tube models
and 1/4 NPT female
on bellows models.
Surface
NOTE:
Panel mount
square case models
do not include
mounting flange and
include bolt circle
shown in Panel Mount
Enclosure versions
(see below).
120
120
120
5-7/16 in.
(138 mm)
2-57/64 in.
(73 mm)
Mounting Hole
4-3/4 in. (121 mm)
diameter.
Process Connection
1/4 NPT Male.
Panel
1/4 in. (6 mm) dia.
holes (3 places.)
on 5-13/64 in.
(132 mm) b.c.
(bolt circle),120
apart, clocking
as shown
Dimensions
Surface / Panel Mount Enclosure (Square Case)
Panel Mount Enclosure
(Round Case)
Typical Applications
Above Ground Tank
Below Ground Tank
SWICHGAGE
®
Flow regulator
(recommended)
Pressure
regulator
Head
Pressure
Air compressor
Tank
Tank
SWICHGAGE
®
Direct Mount
Remote
SWICHGAGE
®
with Sensing Line
Underground
Direct and Remote Tank
Flow regulator
(recommended)
Pressure
regulator
SWICHGAGE
®
1 foot
Ground surface
Air compressor
Underground tank
(vented)
OPLH-94122B page 4 of 4
How to Order
Base Part Numbers
Latching Control Relay Voltage
(applies to “BP” models only)
Blank = 120 VAC
2 = 12 VDC
4 = 24 VDC
Bourdon Tube/Bellows
OPLHC Standard=Bronze/Brass
OPLHACS Standard=316 Stainless Steel
Range/Scale (specify in feet)*
Bellows Tube
05 = 0-5 ft. X
10 = 0-10 ft. X
20 = 0-20 ft. X X
30 = 0-30 ft. X X
60 = 0-60 ft. X
120 = 0-120 ft. X
*Standard calibration is for water–specify
for other.
Options (see Specifications on page 2
for availability)
ES = Environmentally sealed
EX = Explosion-proof
EL = (EXLC) Explosion-proof less case
LC = Less case
TA = (TCA) Tickler contact
Internal Wiring
Red White
Black
120 VAC
BLUE
YELLOW
BROWN
WHITE
= 18 GA.
= 16 GA.
BLACK
RED
ORANGE
LOW
(RESET)
HIGH
(SET)
SET
RESET
3
6
4
1
7
9
A
B
8
3
5
4
1
2
6
LINE
NEUTRAL
COMMON
Contact Ratings: SPDT center off;
2 A, 30 VDC, 1 A, 125 VAC pilot duty.
Contact Ratings: SPDT dry relay contacts,
10 A, 125 VAC.
OPLHC, OPLHACS,
and OPLHAFP
Series
Red White Black
OPLHCE, OPLHFC,
OPLHACES and OPLHAFCS
Series
OPLHBP, and
OPLHABPS Series
Specify model number. NOTE: No designator is required for Standard configurations.
Also, list options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.
OPLHBP – 2 – 30 – TA
OPLHG
OPLHGE
OPLHC
OPLHBP
OPLHAGS
OPLHACS
OPLHABPS
OPLHAFCS
OPLHAFGS
OPLHFG
OPLHFC
OPLHCE
OPLHABPGS
OPLHBPE
OPLHAGES
OPLHACES
45LHE
45LHEF
45LHEBP
Tamperproof Contact Accessory
Knob
Lock
Limit
Switch
Knobs
Order 05000610
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo, Swichgage
®
and Murphygage
®
are registered
and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustra-
tions, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
www.fwmurphy.com
918.317.4100 Email: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Murphy OPLH User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI