Lightolier Sidemount Strip SM STRIP, SM STRIP User manual

  • Hello! I am an AI chatbot trained to assist you with the Lightolier Sidemount Strip SM STRIP User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Sidemount Strip SM STRIP
Page 1 of 2 4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 3A/Folio H120-15
Features
Only 1-13/16" deep.
Efficiency 95.8%..
Ballast cover secured by quarter-turn latches.
Fully enclosed wiring.
May be surface mounted or suspended.
May be continuous row mounted.
Code gauge, heavy duty, die formed steel channel.
Multiple knockouts for convenient installation.
Lampholders may be individually replaced or rewired.
High reflectance baked white enamel finish.
UL Listed for damp locations.
.
1-13/16"
(46mm)
4-1/8"
(105mm)
ONE LAMP
DIMENSIONS
“A”
Channel Length Inches (mm)
2' Channel 24" (610 mm)
3' Channel 36" (914 mm)
4' Channel 48" (1219 mm)
1-13/16"
(46mm)
5-11/16"
(145mm)
TWO LAMP
2"
(51mm)
2-1/2"
(66mm)
1-13/16"
(46mm)
1-1/16" (27mm)
7/8" K.O. (4)
7/8" K.O. (3)
1-1/16" (27mm)
1-1/4"
(32mm)
3-3/4"
(95mm)
SIDE VIEW
TOP VIEW
1/2" K.O. (2)
"A"
Dimensions
Sidemount Strip SM STRIP
Page 2 of 2 4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 3A/Folio H120-15
Job Information Type:
ORDERING INFORMATION Explanation of Catalog Number. Example: SM234HPF120LEGLR
SM
SIDEMOUNT
STRIP
LAMP
QUANTITY:
1 or 2 Lamp
LAMP:
(By Others)
17=(T8), 2' Length
20=T12, 2' Length
25=T8, 3' Length
30=T12, 3' Length
32=T8, 4' Length
34=T12, 4' Length
BALLAST TYPE:
LPF=Low Power
Factor
HPF=High Power
Factor
BALLAST:
1 or 2 Lamp Mag. (T12) LE
Standard Electro Magnetic
(20 or 30 watts only)
P
<20THD <10THD
1 or 2 Lamp Elec. (T8) SO* H
I*
LOL Dimming (T8) PS
*Instant Start Standard
Other dimming options. Consult factory.
OPTIONS:
Add appropriate
suffix to catalog
no., ie: (GLR)
VOLTAGE:
120 or 277
PHOTOMETRY MODEL NO. SM234HPF120LE
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1928782 676461 555351
2837568 575349 474441
3756557 504541 413734
4685749 443934 363229
5635142 393429 322825
6584537 353025 292521
7534133 322622 262219
8493729 292319 242017
9463426 272117 221815
10 43 31 24 24 19 16 20 16 13
room cavity ratio
REPORT NO.: G14162 DATE.: 8/14/91
CATALOG NO.: SM234HPF120LE
LAMP(S): 2 F40 , EACH RATED 3150 LUMENS
EFFICIENCY; 95.8%
LUMINAIRE: SIDE MOUNTED STRIP, MAGNETIC
WATTS: 82.0
CANDELA DISTRIBUTION FLUX
0.045.090.0
00 819 819 819
05 815 814 812 77
15 787 785 791 222
25 731 741 752 341
35 650 673 694 420
45 545 586 628 452
55 422 492 561 440
65 286 400 497 392
75 150 323 462 334
85 41 288 443 291
95 42 276 428 284
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT
00-030 641 10.2 10.6
00-040 1061 16.8 17.6
00-060 1954 31.0 32.4
00-090 2971 47.2 49.3
90-180 3061 48.6 50.7
00-180 6033 95.8 100.0
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG 0-DEG 45-DEG 90-DEG
45 4703 3870 3855
55 4400 3589 3730
65 3916 3373 3728
75 3129 3348 4118
85 1918 4031 5055
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD
PERFORMANCE MAY DIFFER FROM LABORATORY PEFORMANCE.
1-13/16"
(46mm)
5-11/16"
(145mm)
TWO LAMP
LER = FS - 69.9 Watts - 82 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $3.43
OPTIONS & ACCESSORIES
FUSING: Internal fast-blow fusing.
SUFFIX: GLR.
Internal slow-blow fusing.
SUFFIX: GMF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz.
One per fixture. SUFFIX: RF.
STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"),
ASC24 CSP (24").
SPECIFICATIONS:
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel, 1-
13/16" deep x 2-1/2" channel width.
BALLAST: Cover–code gauge cold rolled steel, secured by quarter-turn
latches.
FINISH: Chassis exterior–baked white polyester
enamel, minimum reflectance 86%.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc Listed.
/