Amuheat AT8V2 Operational Manual

Category
Thermostats
Type
Operational Manual
floor heating thermostats
amuheat
AT8V2
Operational Guide
Programmable Thermostat
1. Getting Started
Amuheat’ AT8V2 touch screen thermostats are specifically
designed for underfloor heating systems. The thermostat
offers an automated temperature control of ambient air
temperature, floor temperature or control of ambient temp
whilst maintaining the floor temp within desired limits using an
external temp sensor.
For support call Amuheat on (02) 9114 6934 or visit
www.amuheat.com.au.
LCD Display & Button Legend
The buttons are locked
Heating is turned on
Frost protection activated
Program number
Manual mode
Automatic mode, executes the programmed schedules
Temporary temperature override
The floor sensor is not being read by the thermostat
Economy temperature
Comfort temperature
2. Setting Clock & Day
This thermostat is fitted with a real time clock. It is essential
that the clock time and day are set accurately if you require
your programmed events to start on time. To set follow the
steps below:
1. Touch the time display and the time will start flashing. Use
the up and down arrows to set the time. By holding the arrow
down the time will change faster.
2. Press NEXT to move to the Day setting and use the up and
down arrows to get to the correct day.
3. Press DONE to store and exit.
3. Customise Controller Settings
To enter into the setting menu follow the steps below:
1. Turn the thermostat off by pressing POWER
2. Press MENU and you will then see menu 01
3. Use the up and down arrows to adjust menu setting (refer
to table below)
4. Press NEXT to move to the next Menu and repeat step 3
through all menu option sets (refer to table below)
5. Press DONE to accept and store
Mode/Sensor selector
Switching Differential
Air Temp Calibration
Floor Temp Calibration
Temperature Screen Readout (AF mode only)
Maximum Floor Temp (AF mode only)
A mode = control of ambient temperature
F mode = control of floor temperature (floor probe
must be installed)
AF mode = control of ambient and floor temperature
(floor probe must be installed)
The number of degrees difference before switching.
The default is 1°C which means the thermostat will
switch the heating on 0.5°C below the set
temperature and will turn it off 0.5°C above the set
temperature. With a 2°C differential the heating will
switch on 1°C below the set temperature and will
switch off 1°C above the set temperature.
This is to recalibrate the air temperature if required
This is to recalibrate the floor temperature if required
This gives you the option to show the Air Temperature
(A), Floor Temperature (F) or to show both Air & Floor
at intervals (AF).
This is to protect the floor surface.
Tip: Choose mode A for direct heating or where no
floor sensor is installed, mode F for background
heating or floor warming only, mode AF for timber &
vinyl floors heating
Tip: 1°C is the default/reccommended setting
Tip: Do not change unless required
Tip: Do not change unless required
Tip: Only applicable in AF mode.
Tip: Only applicable in AF mode. Set temp limitation
for timber, vinyl& concrete floors to 27°C, carpet
flooring to 28°C and tiles/screed 30°C.
Menu Feature
01
02
03
04
05
06
Page 1
© 2014 Amuheat Pty Limited
floor heating systems
amuheat
Temperature Format
Program Mode
This alows the temperautre to be set to show °C or °F
00 = Permanent manual mode
01 = Auto mode
Clock Format
Frost Protection
5+2/7DayMode
You can select the clock to show in either 12 or 24
hour time
This is to avoid room temperature going below 5 °C
On = activated
Off = deactivated
This allows you to program either 5 days at once, then
the 2 days of the weekend separately, or a full 7 days
at the same time, or 7 days separately
01 = 5+2 day programmable
02 = 7 day programmable
Tip: Set frost protection to On
Tip: Where automated is the same across the week
irrespective of day, set to 02.
Menu Feature
07
08
09
10
4. Operation
The thermostat has 4 modes of operation. When the
appears on your screen, the floor is heating.
This thermostat has the ability to programme each individual
day of the week separately, or programme 7 days of the
week at once. You can also programme weekdays (5 days)
to one schedule and then weekends (2 days) to a different
schedule.
1. Press SCHEDULE and the day display will start flashing.
Using the arrow to select the day you wish to programme.
Then press NEXT . (If your thermostat is set to 5+2 day
programmable mode, the programming will skip to step 3)
Auto Mode
Refer to Menu 10 to set this up.
Default Schedule
To modify the schedule:
01
02
03
04
WAKE
07:00
LEAVE
09:30
RETURN
16:30
22:30
SLEEP
22 °C
16 °C
22 °C
16 °C
Set to the time you would like to
wake to and the temperature
you want during the morning,
until you leave for the day.
Set to the time you leave home
and the temperature you wish
your home to maintain while you
are away at work perhaps.
Set to the time you return home
at end of the day and the
temperature you want during
evening until bed time.
Set to the time you sleep and the
temperature you want overnight
(usually a comfortable and
energy saving temperature).
Prog Start Time Set Point Explanation
2. To select every day to follow the same program simply
press All Days. Press NEXT
3. The LCD screen will show scheduled programme 1. This is
the first programme function of the day.
4. The default start time for the scheduled program is now
flashing. Adjust the time programme 1 event it should
commence. Then press NEXT
5. The temp is now flashing. Set the temp that you want the
floor to heat to during schedule programme 1 event.
6. Repeat steps 3,4&5tosettheschedule program event
2,3 & 4. Press DONE to store and exit.
Press MODE to select Auto/Manual mode.
In Manual ( )mode, the thermostat maintains a constant
set temperature manually set by the user. To adjust the set
temperature in Manual mode press the temperature and
increase it to the required level. In Auto mode, the
thermostat executes the preprogrammed schedules.
Touch the temperature display, and it will start to flash. Use
the up or down buttons to adjust. Press DONE to accept,
and you will see "Override" above the temperature display.
The thermostat will maintain the new set temperature until
the next programmed event. To cancel the override setting,
press RUN SCHEDULE
The Holiday function reduces the temperature in your room
to the frost protection temperature. The thermostat will
maintain this temperature for the duration of the holiday and
will then automatically return to the programme mode on
your return. Press HOLIDAY and enter the duration of your
holiday. Press DONE . To cancel a Holiday, reduce the
holiday period to 00 days.
To lock the keypad, press and hold the top left corner of the
display for 5 seconds. You will see a lock symbol appear. To
unlock, repeat the steps above and the symbol will
disappear.
With thermostat turned off, press and hold OFF for 5 seconds
until you see --:-- on the LCD screen.
Mode A Control Tip: The recommended air temperature
setting is 19-21°C.
Mode F Control Tip: The recommended floor temperature
setting for tile floors is 24-28°C, carpet 25°C, slab, vinyl &
timber 27°C.
Tip: During the Off or Away periods the floor heating does not
turn off but it heats to the selected set back temperature
(economy temperature). Set back temperature should be
6°C below comfort heating setting. Where no set back is
required or to switch heating off during a programme event,
adjust the heating setting down to the min 5°C.
Tip: If you use the default programming of 5 week days plus 2
weekend days you will now need to repeat the above steps
for the weekend.
Tip: For permanent manual mode, set menu11 in step 2.
Auto/Manual Mode
Temporary Temperature Overide
Holiday Function
5. Lock the Keypad
6. Reset to Factory Settings
Page 2
© 2014 Amuheat Pty Limited
11
floor heating thermostats
amuheat
AT8V2
Installation Guide
Programmable Thermostat
Amuheat’ AT8V2 thermostat is an electronic touch screen
on/off thermostat for temperature control by means of an
NTC sensor located either externally or internally within the
thermostat.
The thermostat is for flush mounting in a wall plate/bracket.
Disconnect the power supply before carrying out any
installation or maintenance work on this control unit and
associated components. This control unit and associated
components should only be installed by a competent person
(i.e. a qualified electrician). Electrical installation must be in
accordance with appropriate statutory regulations.
It is recommended that the sensor cable be placed in a non-
conductive conduit embedded in the floor. The end of the
pipe must be sealed and the pipe placed as high as possible
to the surface of the floor finish.
The sensor cable must be led through a separate conduit
from power cables. The tip of the floor sensor must be
centred between the heating cables.
The sensor cable may be extended up to 100m by means of
a separate two-core cable. The two-core cable must be
placed in a separate pipe or segregated from power cables.
The room sensor is used for comfort temperature regulation in
rooms. The thermostat should be mounted on the wall
approx. 1.6 m above the floor in such a way as to allow free
air circulation around it. Draughts and direct sunlight or other
heat sources must be avoided.
Carefully separate the front half of the thermostat from the
back plate by placing a small flat head terminal driver into
the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged into
the front half of the thermostat.
Place the thermostat front half somewhere safe. Terminate
the thermostat as shown.
Screw the thermostat back plate on to the flush box
Re-connect the thermostat ribbon cable and clip the two
halves together.
WARNING
Installation of the External Floor Sensor
Mounting the Thermostat with Built-in Sensor
– Important Safety Instructions.
Mounting of thermostat
Alternatively, the sensor can be embedded directly in the
floor. Note this will make replacing the sensor impossible
should it fail.
Page 1
© 2014 Amuheat Pty Limited
First time settings:
Programming
The first time the thermostat is connected the Time, Date and
Controller settings must be configured. See operational
guide.
See user manual.
Technical Data
Supply voltage
Output relay
Temp. range
Floor. range
Clock function
Battery backup
Ambient temp
On/Off differential
Protective housing
Housing material
External sensor
Size
Approvals
Warranty
230V AC
16A resistive load
+5/+35°C
+5/+40°C
4-event program
1 x Cr1220 3V
0/+40°C
0.5°C
Ip20
NTC (10K Ohms)
120mm×80mm×16mm
CE
3 Years
PC+ABS
Amuheat Pty Limited
Lg1 64 Talavera Road Macquarie Park NSW 2113
Tel: +61 2 9114 6934 Fax: +61 2 8211 5180
[email protected] www.amuheat.com.au
Floor Sensor
LOAD (16A)
FEED (230VAC)
L
NN
L
654321