Molex CORESYNC 1807981000 Installation guide

Category
Gateways/controllers
Type
Installation guide

Molex CORESYNC 1807981000 is a Power over Ethernet Gateway that conforms to UL 2108 standard and is certified to CAN/CSA standard C22.2 NO. 250.0. It is suitable for damp locations and must be installed by a qualified electrician. The device has a power input of 60VDC maximum and a maximum cable length of 100 meters. The PoE Gateway has three indicator lights: Power, Link, and Active.

Molex CORESYNC 1807981000 is a Power over Ethernet Gateway that conforms to UL 2108 standard and is certified to CAN/CSA standard C22.2 NO. 250.0. It is suitable for damp locations and must be installed by a qualified electrician. The device has a power input of 60VDC maximum and a maximum cable length of 100 meters. The PoE Gateway has three indicator lights: Power, Link, and Active.

ENGINEERING RECORD
NO : XXXXXX
SAP NO : 1807981000
Doc No: 1807981000
Doc part: AS
REV- A
http://www.molexces.com
MPN/FMT-042 (2019/DEC/23 REV-03).
THIS INFORMATION IS CORRECT AS AT THE TIME OF PUBLICATION, SPECIFICATION ARE SUBJECT TO CHANGE. SHEET No. 1 of 2
BEFORE INSTALLING OR ADJUSTING THIS PRODUCT,
PLEASE READ THESE INSTRUCTIONS CAREFULLY.
PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE
CORESYNC POWER OVER ETHERNET GATEWAY UNREGULATED 2.0 90W
1.0 SCOPE
THIS DOCUMENT WILL PROVIDE INSTALLATION INSTRUCTIONS OF CORESYNC POWER OVER ETHERNET
GATEWAYUNREGULATED 2.0 90W
2.0 PRODUCT DESCRIPTION
CORESYNC POWER OVER ETHERNET GATEWAY UNREGULATED 2.0 90W (1807981000), Conforms to UL 2108
standard Certified to CAN/CSA standard C22.2 NO. 250.0
3.0 CAUTION AND WARNING:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
GATEWAY MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN. (CHECK WITH LOCAL AND
NATIONAL CODES FOR PROPER INSTALLATION).
RISK OF ELECTRIC SHOCK. DO NOT HANDLE ENERGIZED GATEWAY WITH WET HANDS OR WHEN
STANDING ON WET OR DAMP SURFACES.
OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE GATEWAYS.
USE ONLY WITH CLASS 2 POWER UNIT 60VDC MAXIMUM.
WARRANTY VOIDED IF GATEWAY HAS BEEN MODIFIED FROM ITS ORIGINAL CONFIGURATION.
DO NOT USE OUTDOORS.
SUITABLE FOR DAMP LOCATIONS.
4.0 PROCEDURES
Step 1. Refer the below mounting pattern as shown below to mount the Gateway 2.0.
Step 2. Snap in the wire harness male connector into the female connector as shown below to connect to the
Core Sync bus as shown below.
ER NO : XXXXXX
SAP NO : 1807981000
Doc No: 1807981000
Doc part: AS
REV-A
MPN/FMT-042 (2019/DEC/23 REV-03). SHEET No. 2 of 2
Step 3. Use two #8 self-tapping screws to mount the PoE Gateway as shown (screws not provided).
Step 4. Make sure the Core Sync bus is connected before plugging in the PoE cable. Use a UTP (unshielded twisted pair)
CAT5E or CAT6 cable*. The maximum length of cable should not exceed 100 meters.
(DO NOT CONNECT OR DISCONNECT CORESYNC BUS WHILE DEVICE IS POWERED.
*Please note the Power LED indicator will turn on once you have power. The LINK and ACTIVE indicators will blink on and off rapidly
once you have network connection.
Note: SAVE THESE INSTRUCTIONS
  • Page 1 1
  • Page 2 2

Molex CORESYNC 1807981000 Installation guide

Category
Gateways/controllers
Type
Installation guide

Molex CORESYNC 1807981000 is a Power over Ethernet Gateway that conforms to UL 2108 standard and is certified to CAN/CSA standard C22.2 NO. 250.0. It is suitable for damp locations and must be installed by a qualified electrician. The device has a power input of 60VDC maximum and a maximum cable length of 100 meters. The PoE Gateway has three indicator lights: Power, Link, and Active.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI