ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1008
UK
SCAN
NEW
UK - ASSEMBLY AND INSTRUCTIONS MANUAL
SCAN
1008/1008-S
1008/1008-S
2
SCAN 1008 NEW
CONGRATULATIONS
ON YOUR NEW SCAN
BUILT-IN STOVE
NEW
You have purchased a product by one of Europe’s leading manufacturers of
wood-burning stoves, and we are sure that you will have years of pleasure from your
purchase. To make the best possible use of your built-in stove, it is important that
you follow our advice and instructions.
Read through this Assembly and Instructions Manual carefully before you start to
assemble your stove.
UK
SCAN
3
CONTENTS
¬¬
MOUNTING THE UK - BLOCKING AND SCREW 43
¬¬
TECHNICAL DATA 4
Installation 4
Safety 4
Technical data and dimensions 5
Dimensional drawing for Scan 1008 6
Dimensional drawing for Scan 1008-S 7
Type plate 8
Product registration number 8
¬¬
ASSEMBLY 9
Tools for the mounting of the built-in stove 9
Loose parts 9
Additional accessories 9
Disposal of packaging 9
Fresh air intake 10
Closed combustion system 10
Load-bearing foundation 10
Convection air 10
Existing chimney and pre-fabricated element chimney 10
Connection between built-in stove and steel chimney 10
Requirements for chimney 11
Internal installation in non-flammable material 11
Distance to furniture 11
Safety distance 11
Building into flammable material with fire wall 12
Using the lifting fittings 15
Remove packaging 15
Fitting the flue connection piece 17
Door (Self-closing) 19
Height adjustment of the built-in stove 20
Floor plate 20
Fastening to the rear wall 21
Dismounting of the frame 22
Building around the frame 24
Mounting of convection grate 31
¬¬
INSTRUCTIONS FOR USE 33
CB-technology (Clean Burn) 33
Baffle plate 33
Ash container 33
Primary air 33
Secondary air 33
Adjustment of primary- and secondary air 34
¬¬
INSTRUCTIONS FOR HEATING 35
Environmentally friendly operation 35
Lighting 35
”Top down” lighting 35
Continuous operation 36
Warning about over-firing 36
Firing in the spring or autumn 37
The function of the chimney 37
Using the stove in various weather conditions 37
General notes 37
Chimney fire 37
¬¬
HANDLING OF THE FUEL 38
Selecting wood/fuel 38
Preparation 38
Storing 38
Moisture 38
Use of the following as fuel is illegal 38
Calorific value of the wood 38
¬¬
MAINTENANCE 39
Sweeping the chimney and cleaning the stove 39
Checking the stove 39
Servicing 39
Combustion chamber lining 39
Gaskets 39
Painted surfaces 39
Cleaning the glass 40
Removing the baffle plate and the baffle unit 40
Disposal of stove parts 40
¬¬
TROUBLESHOOTING 41
¬¬
WARRANTY 42
4
TECHNICAL DATA
INSTALLATION
¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local
building regulations as well as the information provided in this Assembly and Instructions Manual.
¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition
you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan
dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
SAFETY
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as
intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case
if parts that are necessary for the operation and safety of the stove are dismantled or removed.
YOU ACHIEVE AN OPTIMAL
BENEFIT OF THE STOVE BY
FOLLOWING THE ADVICE
GIVEN UNDER:
"INSTRUCTIONS FOR HEATING"
PLEASE NOTE!
5
* The stove can take logs up to 30 cm (horizontally placed).
** Intermittent operation in this context means normal use of
a wood-burning stove. In other words, you should let the fire
die down until only the embers are left before refuelling.
Scan 1008/1008-S is produced in accordance with type
approval for the product, which also covers the product’s
Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from www.
scan.dk
Tested in accordance with EN 13229
CO Emission at 13% O
2
0,06 %
CO
Emission at 13% O
2
800 mg/Nm
3
Dust @ 13% O
2
<6 mg/Nm
3
No
x
@ 13% O
2
81 mg/Nm
3
Efficiency 84 %
Energy efficiency index 112,8
Energy efficiency class A+
Nominal output 6 kW
Chimney temperature EN 13229 195 °C
Temperature in flue conn. piece 233 °C
Amount of smoke 6,3 g/sec
Negative pressure EN 13229 12 Pa
Recommended negative pressure
in flue connecting piece
17-20 Pa
Required combustion air supply 19 m
3
/h
Fuel Wood
Fuel consumption 1,9 kg/h
Amount of fuel required to light 1,5 kg
Amount of fuel, max. 2,25 kg
Materials
Steel plate,
Cast iron
Galvanised sheet
Vermiculite
Surface treatment Senotherm
Max. log length 25 cm*
Weight Scan 1008 ca. 82 kg
Weight Scan 1008-S ca. 138 kg
Flue conn. piece internal diameter 144 mm
Flue conn. piece external diameter 148 mm
Approval type Intermittent**
TECHNICAL DATA AND DIMENSIONS
EN test was carried out on the installation with an un-insulated
elbow pipe shown on page 13.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580046.idw
90580046
Scan 1008 - målskitse
17-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
2
0
8
1
5
6
6
5
4
2
4
208
2
0
8
158
6
8
3
3
0
9
-
3
1
9
2
3
8
-
2
4
8
9
2
8
-
9
3
8
14
5
1
5
7
1
0
9
6
-
1
1
0
6
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580046.idw
90580046
Scan 1008 - målskitse
17-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
2
0
8
1
5
6
6
5
4
2
4
208
2
0
8
158
6
8
3
3
0
9
-
3
1
9
2
3
8
-
2
4
8
9
2
8
-
9
3
8
14
5
1
5
7
1
0
9
6
-
1
1
0
6
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580046.idw
90580046
Scan 1008 - målskitse
17-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
2
0
8
1
5
6
6
5
4
2
4
208
2
0
8
158
6
8
3
3
0
9
-
3
1
9
2
3
8
-
2
4
8
9
2
8
-
9
3
8
14
5
1
5
7
1
0
9
6
-
1
1
0
6
AB
C
D
C
D
6
DIMENSIONAL DRAWING FOR SCAN 1008
A
Centre rear outlet
B
Height to the beginning of flue
connecting piece at top outlet
C
Centre of fresh air intake
D
Connecting piece for flue pipe (int. and ext. measure)
E
Centre to 90° curved elbow pipe 320 x320 mm
F
Centre to 2 x 45° elbow pipe 245x245 mm
All measures are in mm.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580066.idw
90580066
Scan 1008-S - målskitse
16-05-2018
ken
Scan 1008-S
VÆGT:
AREAL:
N/A
N/A
6
8
3
1
8
1
7
,
5
5
1
2
5
1
2
4
4
0
,
5
1
2
0
1
,
5
1
4
9
2
1
5
6
7
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580067.idw
90580067
Scan 1008-S - målskitse
28-05-2018
ken
Scan 1008-S
VÆGT:
AREAL:
N/A
N/A
1
5
8
6
8
3
1
4
5
1
5
7
3
8
3
5
8
0
,
5
6
8
1
9
2
6
8
3
383
3
8
3
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580067.idw
90580067
Scan 1008-S - målskitse
28-05-2018
ken
Scan 1008-S
VÆGT:
AREAL:
N/A
N/A
1
5
8
6
8
3
1
4
5
1
5
7
3
8
3
5
8
0
,
5
6
8
1
9
2
6
8
3
383
3
8
3
D
C
C
A
E
F
7
DIMENSIONAL DRAWING FOR SCAN 1008-S
E
Centre to 90° curved elbow pipe 320 x320 mm
F
Centre to 2 x 45° elbow pipe 245x245 mm
All measures are in mm.
8000000
Scan 1008
Insert appliance fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13229 DoP 90580601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13229
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 6 mg/Nm³
Flue gas temperature: 195°C
Nominal heat output: 6 kW
Efficiency: 84%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to heat insulation:
Side: 25 mm - Back: 25 mm - Front: 800 mm
Minimum insulation:
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2018
0,06% 800 mg/Nm³
Germany Stufe 2 Teknologisk Institut
Scan 1008-S
Freestanding room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
Reaction to fire: A1
Country
EN 13240 DoP 90580602
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN13240:2001
NS 3058
ELAB-2100-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 6 mg/Nm³
Flue gas temperature: 195°C
Nominal heat output: 6 kW
Efficiency: 84%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 0 mm - Back: 0 mm - Front: 800 mm
Follow assembly- and instructions manual.
CO emission at 13% O2:
Follow assembly- and instructions manual.
Use only recommended fuels.
The appliance can be operated in a shared flue.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2018
0,06% 800 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
8
PRODUCT REGISTRATION NUMBER
All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of
this manual; you will always need to quote it when contacting your dealer or Scan A/S.
The product registration number is placed loose in the fireplace.
TYPE PLATE
All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materi-
als.
The type plate is placed loose in the fireplace.
Type plate Scan 1008
Product registration number
Type plate Scan 1008-S
9
ASSEMBLY
TOOLS FOR THE MOUNTING OF THE BUILT-IN STOVE
¬ Spirit level ¬ 2.5 + 3 + 4 mm Allen key
¬ Cutting nippers ¬ 2 pcs. 10 mm spanners (or adjustable spanners)
¬ 8 mm box spanner
Extra tools for Scan 1008-S:
¬ Cordless electric drill ¬ Compass saw
¬ Tape measure/foot rule ¬ Large pair of scissors
¬ Caulking gun ¬ Torx slotted bits
¬ Pozidrive
LOOSE PARTS
The following loose parts are located in the built-in stove's combustion chamber:
¬ Oven mitt ¬ Two flue connection pieces (int. and ext. flue pipe)
¬ Gasket for flue connecting piece ¬ Screws for fastening the flue connection piece
¬ Ash container ¬ 8 fittings and screws for the surround
¬ Type plate and product registration number ¬ UK-blocking and screw
Extra parts for Scan 1008-S:
¬ Top plate
¬ Convection grate (complete)
¬ Surround kit consisting of:
Glue cartridge Calcium Silicate Surround
Joint tape 50 torx-slotted screws 6.0 x 90 (T30)
5 corner strips Felt knobs
ADDITIONAL ACCESSORIES
¬ Floor plates (see page 20)
¬ Cover plate for corner installation Scan 1008-S (See page 30)
¬ Convection grates (See page 31)
DISPOSAL OF PACKAGING
Your Scan built-in stove may come supplied with the following packaging:
Wood packaging
The wood packaging can be reused and after final use can be incinerated as a CO
2
neutral
product or sent for recycling.
Polystyrene top Send for recycling or waste disposal.
Foam Send for recycling or waste disposal.
Plastic bags Send for recycling or waste disposal.
Stretch/plastic film Send for recycling or waste disposal.
10
FRESH AIR INTAKE
In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that
there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close to the wood
stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.
CLOSED COMBUSTION SYSTEM
You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home.
External combustion air is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when the stove is not in use. Minimum
Ø 100 mm ventilation pipe,
maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes.
NOTE: if the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove
is in use!
LOAD-BEARING FOUNDATION
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any rein-
forcement of the beam structure. They can be positioned on ordinary beams/floor.
You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove
and, where applicable, a steel chimney, if you have opted for this solution.
CONVECTION AIR
Scan 1008: The covering must contain holes for convection air.
Convection means that there is an air circulation ensuring that the heat is equally distributed in the room. It is important that the
demands concerning convection areas are observed. Scan 1008-S complies with these demands.
¬ Min. area for ingoing convection air: 300 cm
2
¬ Min. area for outgoing convection air: 500 cm
2
If there is not enough convection air, the covering may be damaged.
Convection air grids for Scan 1008 are available as an accessory.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim-
ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬ When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the
relevant chimney type.
CONNECTION BETWEEN BUILT-IN STOVE AND STEEL CHIMNEY
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the
chimney will match your wood-burning stove.
11
REQUIREMENTS FOR CHIMNEY
The chimney must have a minimum internal diameter of 148 mm and have a T400 designation, with G for the soot fire test.
If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the
horizontal part can be cleaned through here.
As a general rule, the length of the chimney should not be less than 4 metres, measured from the top of the stove. Specific
weather or installation conditions might require a different length.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
¬ Choosing the wrong length or diameter of steel chimney could impair functionality.
¬ Always comply exactly with the instructions provided by the steel chimney supplier.
INTERNAL INSTALLATION IN NON-FLAMMABLE MATERIAL
Scan 1008: There are no demands concerning the distance to non-flammable materials, but we recommend a distance of 25 mm
in order to facilitate the cleaning of the stove, the flue pipes and the chimney and to prevent possible damages to the wall.
DISTANCE TO FURNITURE
Distance to furniture: min. 800 mm.
You should however assess whether furniture or other items might become excessively dry due to being too close to the stove.
The stove is NOT to be built into flammable materials without the use of a fire wall!
SAFETY DISTANCE
European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied
with.
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580001.idw
90580001
Opstillingsafstand, hjørne, Scan 1008
03-03-2017
sr
Scan 80
Weight:
Area:
N/A N/A
3
5
0
m
m
25 mm
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580004.idw
90580004
Opstillingsafstand, parallel, Scan 1008
20-02-2018
Ken
Scan 1008
Weight:
Area:
N/A N/A
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
2
5
m
m
250 mm
450 mm
5
8
0
m
m
2
5
m
m
2
5
mm
1
0
3
0
m
m
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580001.idw
90580001
Opstillingsafstand, hjørne, Scan 1008
10-03-2017
ken
Scan 1008
Weight:
Area:
N/A N/A
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
25 mm
2
5
m
m
3
5
0
m
m
2
0
0
m
m
*
*
*
*
12
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
* Distance to glass
45° corner installation Parallel installation
- SCAN 1008
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580001.idw
90580001
Opstillingsafstand, hjørne, Scan 1008
03-03-2017
sr
Scan 80
Weight:
Area:
N/A N/A
3
5
0
m
m
25 mm
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580003.idw
90580003
Opstillingsafstand, hjørne, Scan 1008
31-01-2018
ken
Scan 1008
Weight:
Area:
N/A N/A
Loft
Gulv
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
M
i
n
.
3
0
0
m
m
M
i
n
3
5
0
m
m
Min. 300 cm² konvektion
**
**
13
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
** Distance to flammable floor
Installation with an insulated, vertical flue pipe
Installation with an un-insulated elbow pipe
convection
convection
convection
The distance to fire wall (brick) depends on the use of an
insulated flue pipe with min. 30 mm insulation all the way
down to the insert
- SCAN 1008
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580001.idw
90580001
Opstillingsafstand, hjørne, Scan 1008
03-03-2017
sr
Scan 80
Weight:
Area:
N/A N/A
3
5
0
m
m
25 mm
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580064.idw
90580064
Opstillingsafstand, hjørne, Scan 1008-S
17-04-2018
KEN
Scan 1008-S
Weight:
Area:
N/A N/A
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580063.idw
90580063
Opstillingsafstand, parallel, Scan 1008-S
17-05-2018
KEN
Scan 1008-S
Weight:
Area:
N/A N/A
250 mm 450 mm
5
8
0
m
m
9
9
2
m
m
114 mm
313 mm
*
*
*
14
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
* Distance to glass
45° corner installation Parallel installation
- SCAN 1008-S
A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580061.idw
90580061
Scan 1008 med træramme
29-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
1
2
A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580061.idw
90580061
Scan 1008 med træramme
29-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580061.idw
90580061
Scan 1008 med træramme
29-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
C
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580073.idw
90580073
Scan 1008 - Brug af løftebeslag
29-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
C
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580073.idw
90580073
Scan 1008 - Brug af løftebeslag
29-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
15
REMOVE PACKAGING
Before installing the stove, check that it has no damages.
NOTE: Do not touch the glass
Remove the 4 screws from the
lifting bracket
Then remove the screws connect-
ing the lifting bracket with the
built-in stove. Remove the lifting
bracket and the wood frame
USING THE LIFTING FITTINGS
When moving the insert before it is removed from the pallet, you must use the lifting fittings in order to avoid twisting the glass.
Install two steel tubes with a diameter of max. 25 mm thrugh the holes in order to lift the stove.
PLEASE NOTE: If the insert is to be moved, after it has been removed
from the pallet, the door must be opened or dismounted!
H
J
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580041.idw
90580041
Scan 1008 på palle
27-02-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
H
J
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580041.idw
90580041
Scan 1008 på palle
27-02-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
3
K
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580072.idw
90580072
Scan 1008-S på palle
23-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
Scan 1008
Scan 1008-S
K
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580072.idw
90580072
Scan 1008-S på palle
23-05-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
16
REMOVE PACKAGING
NOTE: The stove must be taken off the pallet by removing the screws. Do not knock off the pallet, as this can damage the stove.
The built-in stove is mounted
on the pallet with 6 screws
(Scan 1008)/4 screws (Scan
1008-S). Please remove these.
NOTE: it is important that the
door is not opened after
removing the screws, as the
stove may easily tilt!
A ( 1 : 5 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580042.idw
90580042
Scan 1008 - montage røgstuds i topafgang
07-12-2017
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
A ( 1 : 5 )
A
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580027.idw
90580027
Montage af røgstuds
16-05-2017
jwa
Weight:
Area:
N/A N/A
4 x unbraco M5 x 10
Røgstuds til indvendig skorsten
A ( 1 : 5 )
A
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580027.idw
90580027
Montage af røgstuds
16-05-2017
jwa
Weight:
Area:
N/A N/A
4 x unbraco M5 x 10
Røgstuds til indvendig skorsten
4x
A ( 1 : 5 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580042.idw
90580042
Scan 1008 - montage røgstuds i topafgang
07-12-2017
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
17
Connection piece
for external flue
pipe
Connection piece for
internal flue pipe
FITTING THE FLUE CONNECTION PIECE
The gasket for the flue connection piece, flue connection piece and screws can be found in the stove’s combustion chamber.
Gasket
IN THE TOP OUTLET
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580055.idw
90580055
Scan 1008 - montage af røgstuds i bagafgang
22-02-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580054.idw
90580054
Scan 1008 - montage af røgstuds i bagafgang
17-01-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580054.idw
90580054
Scan 1008 - montage af røgstuds i bagafgang
17-01-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
2 3
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580055.idw
90580055
Scan 1008 - montage af røgstuds i bagafgang
22-02-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
1
18
FITTING THE FLUE CONNECTION PIECE IN THE REAR OUTLET
The gasket for the flue connection piece, flue connection piece and screws can be found in the stove’s combustion chamber.
Using cutting pliers, cut
off the cover plate from
the rear plate and the heat
shield at its securing points.
Remove the gasket
and the cover from the
stove’s rear outlet.
Fit the gasket and the cover in the
stove’s top outlet and tighten it.
Reposition the top module.
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580056.idw
90580056
Scan 1008 - montage af røgstuds i bagafgang
22-01-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580056.idw
90580056
Scan 1008 - montage af røgstuds i bagafgang
22-01-2018
ken
Scan 1008
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580043.idw
90580043
Scan 1008 - låge selvluk
07-12-2017
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
A ( 1 : 5 )
A
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580027.idw
90580027
Montage af røgstuds
16-05-2017
jwa
Weight:
Area:
N/A N/A
4 x unbraco M5 x 10
Røgstuds til indvendig skorsten
4x
C ( 1 : 2 )
C
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580037.idw
90580037
Opspænding af bauart fjeder
04-10-2017
jwa
Scan 80
Weight:
Area:
N/A N/A
4
D ( 1 : 5 )
E ( 1:1 )
D
E
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580028.idw
90580028
højdejustering
16-05-2017
jwa
Scan 80
Weight:
Area:
N/A N/A
Bagklap fjernes ved at løfte op og "vippe" øverste kant ud
19
Connection piece for
external flue pipe.
Tighten the flue connection piece
with the delivered screws.
FITTING THE FLUE CONNECTION PIECE IN THE REAR OUTLET
Gasket
DOOR (SELF-CLOSING)
The door is delivered without self-closing function.
NB: If you want a self-closing door, the spring can be tightened by turning the long screw (inside the spring) clockwise
using a Allen key (5 mm) and at the same time tightening the pointed screw at the bottom with a Allen key (2.5 mm).
Long screw
Pointed screw
E
H
J
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580057.idw
90580057
Scan 1008 - højdejustering
09-03-2018
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580045.idw
90580045
21-12-2017
ken
Scan 1008 - gulvplader
VÆGT:
AREAL:
5,63 kg
753347 mm^2
DIMENSION:
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580045.idw
90580045
21-12-2017
ken
Scan 1008 - gulvplader
VÆGT:
AREAL:
5,63 kg
753347 mm^2
DIMENSION:
2
1
E
H
J
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580057.idw
90580057
Scan 1008 - højdejustering
09-03-2018
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
D ( 1 : 5 )
E ( 1:1 )
D
E
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580028.idw
90580028
højdejustering
16-05-2017
jwa
Scan 80
Weight:
Area:
N/A N/A
Bagklap fjernes ved at løfte op og "vippe" øverste kant ud
E
H
J
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580057.idw
90580057
Scan 1008 - højdejustering
09-03-2018
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
E
H
J
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 80\90580057.idw
90580057
Scan 1008 - højdejustering
09-03-2018
ken
VÆGT:
AREAL:
N/A
N/A
DIMENSION:
3
20
FLOOR PLATE
If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any
non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable material against any sparks that may occur.
NOTE: The stove must be levelled, before the stove is moved into place.
Large shaped floor plate in clear or
smoke-coloured glass
Small floor plate in clear or
smoke-coloured glass
HEIGHT ADJUSTMENT OF THE BUILT-IN STOVE
Scan 1008 is delivered on a small rack. If you want to install the stove in a higher position, the rack can be blocked up on a solid
foundation of non-flammable material.
We recommend to fasten the
fittings with the two screws to the
floor.
The stove is equipped with eight
adjustment screws, of which three
are used to ensure that the stove
is level.
Fasten the five remaining
screws until they meet resis-
tance in order to ensure that
the built-in stove is stable.
(ACCESSORY)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

SCAN 1008 Assembly And Instruction Manual

Category
Stoves
Type
Assembly And Instruction Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI