Leviton R50-3W102-00E User manual

Type
User manual
15A Grounding Plug & Connector
Cat No. 3W101 - Plug (Nema 5-15P)
Cat No. 3W102 - Connector (Nema 5-15R)
PK-93767-10-02-1A
INSTALLATION
ENGLISH
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST
THAT THE POWER IS OFF BEFORE WIRING OR SERVICING!
• To be installed and/or used in accordance with electrical codes and regulations.
• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.
• UsethisdeviceONLY WITH COPPER OR COPPER CLAD WIRE.
NOTE: Refer to NEC tables (in U.S.A), article 400 for proper wire type and size for your application and load.
TO INSTALL
1. Backoutassemblyscrewandopendevice.
2. Stripcordjacket11/2"(3.8cm)maxforplugand13/4"(4.4cm)forconnector.Stripinsulationtoexpose3/4"
barecopperattheendofeachconductorperstripgaugeondevice.Trimoffcordllersifany.Twiststranded
conductorspriortowrappingaroundterminalscrews.DO NOT TIN CONDUCTORS.
3. Connectwiresperwiringdiagramsasfollows:WHITE conductor to SILVER screw. BLACK conductor to BRASS
screw. Ground conductor to Green screw.
4. Loopwiresclockwise3/4turnaroundterminalscrews.Tightenscrews9in.-lbs.minimum.
5.
Closesideofthedevicewithoutscrew,makingsurecordisseatedinwiringchannelandallthreeinsulatedwires
arepositionedaroundthescrewrib.Closetheothersideofthedeviceandtightenassemblyscrewto8-10in.-lbs.
oftorque.
6.Restorepoweratcircuitbreakerorfuse.INSTALLATION IS COMPLETE.
SPECIFICATIONS
RoundCordAWG:SJ16/3 RoundCableRange:0.325"to0.360"
Plug / Fiche / Clavija
Assembly Screw
Vis d'assemblage
Tornillo de Ensambl
e
Brass Screw
Vis argent
Tornillo Latón
Green Screw
Vis vert
Tornillo Verde
Wire Channel
Goulotte passe-fils
Canal de Cableado
Silver Screw
Borne laiton
Tornillo Plateado
Connector / Connecteur / Conector
Silver Screw
Vis laiton
Tornillo Plateado
Assembly Screw
Vis d'assemblage
Tornillo de Ensambl
e
Brass Screw
Vis argent
Tornillo Latón
Wire Channel
Goulotte passe-fils
Canal de Cableado
Green Screw
Vis vert
Tornillo Verde
Strip Gage For Plug / Gabaritdedénudagepourlesches
Medida de pelado para la Clavija
3/4" (1.9 cm)
3/4 po (1,9 cm)
1 1/2" (3.8 cm) / 1 1/2 po (3,8 cm)
Cord Jacket
Gaine
Forro del Cordón
White / blanc / Blanco
Green / vert / Verde
Black / noir / Negro
Strip Gage For Connector /Gabaritdedénudagepourles
connecteurs / Medida de pelado para el Conector
White / blanc / Blanco
Green / vert / Verde
3/4" (1.9 cm)
3/4 po (1,9 cm)
Black / noir / Negro
1 3/4" (4.4 cm) / 1 3/4 po (4,4 cm)
Cord Jacket
Gaine
Forro del Cordón
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) - www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterials
andworkmanshipundernormalandproperusefortwoyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,at
itsoption,ifwithinsuchtwoyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co.,
Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlabor
forremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,
abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,the
durationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtotwoyears.Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure
to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.