Required tools:
No. 2 Phillips screwdriver Thin blade 1/8” standard screwdriver
Diagonal cutting pliers Electrician knife
7/16” combination wrench Crimp Tool for Wire Joint
Electrical Shock Hazard
Disconnect welding machine from A.C. power source before installing kit.
Installation should be done only by qualified individuals.
1. Remove 8 screws holding handles to the top of machine. Remove both handles and top cover.
2. Viewing machine from the rear, remove the right side panel. Note that the bottom three side panel
holes are slotted. Complete removal of these three screws is not necessary.
3. Remove the #8-32 screw indicated in Figure 1 and discard. Orient the timer module so that mod-
ule terminals 4 and 5 are located on the left side of the module. Mount the timer module to the
welder as shown in Figure 1 using the screw, lock washer, plain washer and spacer provided in the
kit.
4. Locate the large input voltage selector terminal board TB on top of the welder. Carefully fold back
the ‘fish paper’ insulation and remove the 4 screws holding the terminal board to the welder. Lift
the terminal board high enough to gain access to its bottom side.
5. Locate the terminal marked ‘8’. There should be a black wire and a brown wire on the terminal.
Using the 7/16” wrench, remove the nut, lock washer and plain washer from the terminal. Remove
the black wire.
6. Cut the terminal from the black wire. Cut wire as close to terminal as possible. Strip approximately
3/8” insulation from the wire.
7. Route the timer module black wires into the compartment beneath TB. Connect the black timer
module wire without a terminal to the wire stripped in step 6 above. Twist wires together and install
wire nut provided in the kit. Securely tighten wire nut.
8. Connect black timer module wire with ring terminal to TB terminal 8. Brown wire should remain on
TB terminal 8. Replace terminal washer, lock washer and nut and tighten securely.
9. Use two wire ties to dress wires to existing bundle of wires exiting through notch in top of welder
chassis. Reposition TB terminal board taking care not to pinch any wires between terminal board
and welder chassis. Secure with 4 screws removed previously.
10. Locate the large Inverter Control Board printed circuit board (ICB) on top of the welder and then
locate the connector on the PCB labeled P3. This connector will be on the side of the ICB nearest
the rear of the welder. The location of connector P3 position 1 is printed on the ICB. Determine
the location of positions 4 and 5. Route the two violet wires from the timer module to P3 and install
one wire in P3 position 4 and the other wire in P3 position 5. There should be no other wires in
these two terminals. Use the small straight blade screwdriver to securely tighten the terminal
F-15-609
March, 2000
Instructions for
INSTALLATION
SMART FAN TIMER KIT
P/N—0558001742
For ESAB 450i CC/CV Welding Power Supply