Siren Marine SM-ACC-ACRE-120 Operating instructions

Category
Motorcycle Accessories
Type
Operating instructions
NC NONO NC
COM COMCOIL COIL
START
COM A1
NCNO
Wires are not included with
this relay and may not match
the color of your boat wiring
120V AC ground is
not used
S3P 120V Shore Power Relay Wiring Diagram
Battery 1 (+) +9VDC to +30VDC Power
Installation Instructions:
1. Ensure AC power is OFF.
2. Assemble the relay by matching the pins on the gray piece to the sockets on the
blue piece and push together firmly.
3. Connect the "Shore power (light green)" wire from the Siren 3 Pro wiring cable
to one of the normally open (NO) terminals on the relay.
4. Connect a wire from DC Common Ground to the "COM" terminal of the
corresponding relay switch.
5. Connect the AC Hot wire (black) to one of the "COIL" terminals of the relay.
6. Connect the AC Neutral wire (white) to the OTHER "COIL" terminal of the relay.
7. Leave the AC Ground wire (bare wire or green) unconnected to this relay.
Product SKU: SM-ACC-ACRE-120
Note: Posi-Tap? connectors,
terminal block, or other
connection type can be used to
connect the wiring cable to
sensor wires.
DC Common
Ground (-)
Shore Power
120V AC Hot
Text
Wiring Cable 1
(Harness 1)
120V AC Neutral
Note: There are three
separate switches that
can be used on the
relay. Each normally
closed (NC) circuit
correlates with a specific
COM circuit as indicated
by the dotted lines.
For Siren 3 Series Devices
DC Common Ground (-)
DC Common Ground (-)
(Alternative Ground Connection)
  • Page 1 1

Siren Marine SM-ACC-ACRE-120 Operating instructions

Category
Motorcycle Accessories
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI