First Edition • Fourth Printing Operator's Manual Supplement
Introduction
Part No. 1293274GT Positive Air Shutdown 5
Technical Information
Repairs to the machine may only be made by a
service technician that is trained and qualified to
perform maintenance on this machine.
Fault Status Indicator
An LED on the emergency shutdown module will
indicate if a fault has occurred.
There are 5 LED status indicators:
Status Description
LED is Off. Air intake valve is open.
System working properly.
Red LED on solid. Air intake valve closed.
Engine turns off. Engine
does not start.
Red LED blinks On
and Off in 2 second
intervals.
Air intake valve
disconnected from power
source or open circuit.
Red LED blinks in
intervals of 3.
Air intake valve is stuck.
Check air intake for debris
or blockage.
Red LED blinks
during engine start for
5 seconds.
No rpm tach signal
detected. Open circuit..
Override Mode
The air intake valve is designed with a manual
override function that allows the valve to be
adjusted to the open position in case of loss of
power.
The override function should only be used in
situations that require the machine be moved to a
safe location when repairs to the Positive Air
Shutdown system are required.
1 Disconnect the harness from the air intake
valve.
2 Remove the rubber cap from the top of the
valve and set aside.
1 rubber cap
2 adjustment screw
3 air intake valve
3 Turn the adjustment screw clockwise 15 -
20 turns.
4 Install the rubber cap.
5 Connect the harness to the valve.
6 Verify the machine will start and run.
Positive Air Shutdown Part No. 1293274GT Operator's Manual Supplement First Edition • Four th Printing