ICP iKAN-124 User manual

Type
User manual

This manual is also suitable for

WrittenbyTonyLee
EditedbySunnyChiu
iKANSeries
UserManual
Version1.0.1Jan.2016
iKANSeriesModbusLEDDisplayUserManualVersion1.0.1Page:2
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Warranty
AllproductsmanufacturedbyICPDASareunderwarrantyregardingdefective
materialsforaperiodofoneyear,beginningfromthedateofdeliverytotheoriginal
purchaser.
Warning
ICPDASassumesnoliabilityforanydamageresultingfromtheuseofthisproduct.
ICPDASreservestherighttochangethismanualatanytimewithoutnotice.The
informationfurnishedbyICPDASisbelievedtobeaccurateandreliable.However,no
responsibilityisassumedbyICPDASforitsuse,norforanyinfringementsofpatents
orotherrightsofthirdpartiesresultingfromitsuse.
Copyright
Copyright©2016byICPDASCO.,LTD.Allrightsarereserved.
Trademarks
Namesareusedforidentificationpurposesonlyandmayberegisteredtrademarksof
theirrespectivecompanies.
ContactUS
Ifyouhaveanyproblems,pleasefeelfreetocontactusbyemailat:
Youcancountonusforaquickresponse.

iKANSeriesModbusLEDDisplayUserManualVersion1.0.1Page:3
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Table of Contents
1.Introduction ...................................................................................................................................4
2.HardwareInformation ...................................................................................................................8
3.Configuration ...............................................................................................................................13
3.1.Ethernetconfiguration...................................................................................................... 13
3.2.ConnectingtoaremoteDL302device.............................................................................16
3.3.Importing/Exportingpreconfiguratedmessages.............................................................17
3.3.1.Exportingaconfigurationfile.................................................................................17
3.3.2.Importingaconfigurationfile ................................................................................19
3.4.COMportconfiguration ....................................................................................................20
3.5.LEDBrightnessandMessageMotionSpeedadjustment .................................................21
3.6.MISC. .................................................................................................................................23
4.Message s......................................................................................................................................25
4.1.EditingandManagingmessage s.......................................................................................25
4.2.Insertingsystemvariablesintoamessage........................................................................27
4.2.1.DisplayingtheIPAddress.......................................................................................29
4.2.2.DisplayingthecurrentDateandTime ...................................................................31
4.2.3.DisplayingtheCO2andtemperaturevaluesfromaremoteDL302module .......33
4.3.Insertingvariablesintoame ssage....................................................................................35
4.3.1.InsertingaCoilvariableintoamessage ................................................................35
4.3.2.Displayingthevalueofacoilwithreplacementtext.............................................37
4.3.3.Insertinganintegertypevariableintoame ssage.................................................39
4.3.4.DataMappingforIntegertypeVariables...............................................................41
4.3.5.Insertingafloattypevariableintoamessage.......................................................44
4.3.6.Settingthenumberofdecimalplacesforfloattypevariables..............................46
5.WritingVariable ...........................................................................................................................48
5.1.UsingtheiKANWebConfigurationPag e ..........................................................................48
5.2.UsingtheModbusTCP/RTUprotocol ...............................................................................52
6.FirmwareUpdate .........................................................................................................................53
6.1.DownloadingtheLatestFirmwar e....................................................................................53
6.2.InstallingeSearchutility ....................................................................................................54
6.3.Updatingfirmware............................................................................................................54
7.FAQ ...............................................................................................................................................59
7.1.HowtoobtaintheIPaddressfortheiKANdevice?..........................................................59
AppendixA:InstructionforInsertingVariable ................................................................................60
AppendixB:ModbusRegisterTables...............................................................................................61
RevisionRecord................................................................................................................................64
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page4
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
1. Introduction
TheiKANseriesisafamilyofindustrialModbusLEDdisplaydevicesthatdeliverindustrialgrade
antinoisecapabilitiesaswellasreliabilityandstability.Theseriesdisplaydeviceishighlysuitable
forpresentingformattedmessagesinindoorareasusingeitherUnicodecharacters,whichcanbe
usedtodisplaymultiplelanguages,orASCIIcharacters.SupportforthepopularModbus
industrialprotocolisprovidedmeaningthatiKANdisplaydevicescanbeeasilyintegratedinto
existingPLCandSCADAenvironments.
168variablesareprovidedtoallowdatawrittenfromaPCoraPLCtobedisplayedinaformatted
messageinrealtime.Sevencolorsareavailableforthetext,whichcanbeusedtoindicate
differentdegreesofimportanceofthemessage,aswellassignificantlyincreasethereadabilityof
themessageinanindustrialarena.
Messagescanbeeditedusingastandardwebbrowser,suchasGoogleChrome,Firefox,orIE,etc.,
onaPC,mobile device,orsmartphonewithoutanylimitationsrelatedtospecificcontroltoolsor
programs.Thedisplayofindividualmessagescanalsoberemotelyenabledordisabledas
necessaryusingthesamestandardwebbrowser.Eachmodelinthe iKANseriesprovidesstor age
spaceforupto64commonmessagesand10instantmessages,eachcontainingamaximumof40
Unicodecharactersor100ASCIIcharacters.Withanopenuserinterfaceandtheabilitytodisplay
realtimedata,theiKANseriesLEDdisplaycanbeinstalledinavarietyofindoorspaces,including
shoppingmalls,railwaystations,andindustrialareas.
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page5
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Features:
SupportsmultiplelanguageswhenusingUnicodecharacters
Textheightof16cm
7colors,includingred,blue,yellow,green,lightblue,purpleandwhite
Adjustablebrightnessandmessagemotionspeed
Abletostoreupto64commonmessagesand10instantmessages
Abletointegratebothtextandvariablesinasinglemessage
SupportstheModbusTCP/RTUSlaveprotocols
BuiltinRTC(RealTimeClock)
WebbasedUserInterface
Canberemotelycontrolledusingasmartphoneorothermobiledevice
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page6
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Functiondescription
PLCHMI
TheiKANseriescanbeemployedasalargeHMIwithamemorystorageofupto64common
messagesand10instantmessages,eachofwhichcanbeusedtodisplayinformation
generatedbyaPLC.Messagetextcanbedisplayedinarangeofsevencolors,includingred,
blue,yellow,green,lightblue,purple,andwhite,whichcanbeusedtoindicatewarningsor
alarms,aswellasincreasingthereadabilityofamessage.

SupportsMultipleLanguages
TheiKANseriesofdisplaydevicesupportsUnicodeinput,meaningthatmessagescanbe
configuredtobedisplayedinmultiplelanguages.
MessageEditing
Amaximumof64commonmessagesand10instantmessagescanbepreconfiguredfrom
thefirstmomentthattheiKANseriesdisplayisswitchedon.Whenthedisplayisin
operation,thefocusneedsonlybeonmessagemanagementratherthantheneedto
frequentlyupdatethemessages.
CO2:725 PPM
Voltage: 2.35 V
Machine A01: Active
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page7
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
MessagePriority
Instantmessageshaveahigherprioritythancommonme ssages.Onceaninstantmessageis
enabled,thecommonmessagecurrentlybeingdisplayedwillbesuspendeduntil theinstant
messageisdisabled.Thisfeatureallowsthemostimportantinformationtobedisplayedin
anemergencysituation.
Integertypevariablesenabledatamapping
TheiKANseriesofdisplaydevicesprovidetheabilitytoperformdatamappingtotranslatea
computerintegervaluetoareadablephysicalvalue,suchasthevoltage,temperature,or
relativehumidity,etc.Intheindustrialfield,thisisacommonlyperformedtaskbetweenthe
hostcomputerandthedataacquisitiondevicesviatheModbusprotocol,enablinga
reductionintheresourcesandprogrammingrequiredforthehostcomputer
Import/Exportthemessageconfiguration
TheiKANseriesallowsamessageandtheparametersofthevariablestobesavedasa
configurationfile,whichcanthenbeloadedontoanotheriKANseriesdevicetoavoidthe
needtorepeattheconfiguration.
SmartphoneApplication
Userscanmanagemessagesviaaregularsmartphonewithoutrequirementofaspecific
connectiondevice,meaningthatemergencyinformationcanbequicklysenttothedisplay
usingthesmartphone.
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page8
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
2. Hardware Information
Specifications
Model iKAN-116 iKAN-124
Display
Color Red,Blue,Yellow,Green,LightBlue,PurpleorWhite
CharacterSet 16bitUnicodeor7bitASCII
ASCII 16characters 24characters
Display
Size
Unicode 8characters 12characters
MessagePool
64commonmessagesand10instantmessages
Upto40Unicodecharactersor100ASCIIcharacterseach
DataPool 40Coilvalues,64Floatvalues,and64Integervalues
RTC
(RealtimeClock)
Dateandtime,24hourformat,includinghours,minutes,
seconds,dayoftheweek,date,month,year
Ethernet
Port 1xRJ45,10/100BaseTX
Protocol ModbusTCPSlave,Max.8connections
Configuration WebbasedUserInterface
COMPort
Interface RS232orRS485.
Notethattheinterfacescannotbeusedsimultaneously
Baudrate(bps) 1200,2400,4800,9600,19200,38400,57600,115200
DataFormat N81,E81,O81
Protocol ModbusRTUSlave
Power
InputRange 100~240V
AC
Consumption
0.25A@110V
AC
,
0.125A@220V
AC
0.3AA@110V
AC
,
0.15A@220V
AC
Mechanical
Dimensions(WxHxD) 1346mmx160mmx49mm 1986mmx160mmx49mm
Weight 4Kg 5Kg
Installation Wallmounting
HousingMaterial Aluminum
Environment
OperatingTemperature 0to60°C
StorageTemperature 10to75°C
Humidity 10to90%RH,Noncondensing
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page9
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Appearance
Wiring
PowerandEthernetWiring
100~240VAC
PowerSupply
EthernetSwitch
DisplayArea
10/100BaseTXRJ45Connector
Ter minalBlock
‐COM1:RS232
‐COM2:RS485
‐FrameGround
PowerInput:100~240V
AC
Normal/InitSwitch
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page10
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
RS232Wiring
RS485Wiring
RS-232 Device
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page11
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
MountingPlatesInst allation
FastentheleftandrightmountingplatestoiKAN124displaywithfoursuppliedscrewseachside.
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page12
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
Dimensions(Units:mm)
iKAN116
iKAN124
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page13
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
3. Configuration
3.1. Ethernet configuration
ThefactorydefaultIPaddressforeachiKANdeviceis192.168.255.1.BeforeintegratinganiKAN
seriesdisplayintoyournetwork,youshouldconfiguretheIP,Mask,andGatewayaddressesfor
thedevicebysettingthevaluesthatarevalidforyournetworksystem.To dothis,followthe
instructionsgivenbelow.
NOTE:
z OneiKANdeviceuses2adjacentIPaddresses.OnceanIPaddressissetforaniKANdevice,
thenextIPaddresswillbeautomaticallysetforthecontrollerintheiKANdisplay.Ifthe
nextIPaddressisalreadyusedforanyotherdevice,youwillfailtocommunicatewiththe
iKANdisplay.
z DetailsonhowtochangetheIPaddressonyourcomputerdependuponthetype
architectureandoperatingsystemyouareusing.UsetheHelpandSupportfunctionality
onyourcomputerandsearchfor"IPAddressing".
z RemembertheIPaddressonyourcomputerforrestoringitlater.

1. ConnecttheiKANdisplaytotheHostPC,thenpoweronalldevices,asillustratedbelow.
2. SettheIPaddressofyourcomputer
100~240V
AC

Powersupply
EthernetSwitch
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page14
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
ThefactorydefaultIPaddressfortheiKANdeviceis192.168.255.1.Beforeattemptingto
connecttothebuiltinwebconfigurationpageontheiKANdevice,ensurethattheIPaddress
oftheHostPCissettoa validaddressintherange192.68.255.2to192.168.255.253.This
addressshouldbeuniqueandshouldnotbeusedbyotherEthernetdevices.
3. EntertheIPaddressoftheiKANdisplayintheaddressbarofabrowser,suchasGoogle
Chrome,Firefox,orIE,etc.,andthenpressEnter.ThewebconfigurationpagefortheiKAN
devicewillthenbedisplayed.
4. ConfiguretheIP,Mask,andGatewayaddressesfortheiKANdevicebyfollowingthe
instructionsgivenbelow.
n
o
q
p
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page15
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
ClicktheSystemtabatthetopofthepage.
ClicktheETHERNEToptionfromthemenuonthelefthandsideofthepage.
EnteravalidvaluefortheIP,Mask,andGat ewayaddressesinthefieldsinthe
LOCALETHERNETsection.NotethattheIPaddressmustbeuniqueandmustnot
beduplicatedwithotherEthernetdevicesinthenetwork.
ClicktheUpdateSettingsbuttontosavethenewvaluesandcompletethe
configurationprocess.
NotethattheiKANdevicewillbe automaticallyresetonceyouclicktheUpdate
Settingsbutton.
RestoretheIPaddressoftheHostPCtothepreviousvalue.
Repeatstep3above,butenterthenewIPaddressoftheiKANdevice,andthen
pressEntertodisplaythewebuserinterfacethatallowsmessagestobe
preconfigured.
r
q
p
o
n
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page16
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
3.2. Connecting to a remote DL-302 device
TheiKANseriesdevicescanbeusedtodisplaydatasuchasthetemperature,humidityandCO2
valuessourcedfromaspecificremoteDL302devicethatisconnectedtothesamenetworkas
theiKANdevice.OncetheIPaddressfortheDL302devicehasbeenconfigured,thedata
recordedbytheDL302canbeautomaticallyobtained.TospecifytheIPaddressoftherequired
DL302device,followtheinstructionsgivenbelow.
ClicktheSystemtabatthetopofthepage.
ClicktheETHERNEToptionfromthemenuonthelefthandsideofthepage.
EntertheIPaddressforthedesiredDL302.
ClicktheUpdateSettingsbuttontosavethenewvaluesandcompletethe
configurationprocess.
n
o
p
q
n
o
q
p
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page17
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
3.3. Importing/Exporting pre-configurated messages
IfyoursystemcontainsmorethanoneiKANseriesdevice,itcouldtakealotoftimetoconfigure
eachoneindividually.Tosimplifythisprocess,theImport/Exportfunctionthatisfoundonthe
webconfigurationpagecanbeusedtopreconfigurethe contentsofamessageorvariableon
theiKANseriesdevicebefor eusingModbusTCP /RTUcommandstomanagethemessagepool,
therebyreducingtheneedtorepeattheconfigurationtasksmultipletimes.
OnceamessagehasbeenconfiguredfortheiKANdevice,usetheExportfunctiontosavethe
contentsasaCSVfileontheHostPC.ThismeansthatadditionaliKANseriesdisplaydevicescan
beeasilyconfiguredbyimportingthecsvfiletothatdevice.
3.3.1. Exporting a configuration file
n
o
p
q
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page18
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
ClicktheSystemtabatthetopofthepage.
Click the IMPORT/EXPORT option from the menu on the lefthand side of
thepage.
ClicktheSavebuttontosavethecurrentconfigurationasaCSVfile.
Aconfirmationdialogwillbedisplayed,clicktheOKbuttontosavethefile.
ClicktheExportbuttontosavetheconfigurationfiletotheHostPC.
The exported will be saved to the download folder location where your
browsersavesdownloadedfiles. 
n
o
p
q
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page19
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
3.3.2. Importing a configuration file
Thefollowingisadescriptionofhowtoimportapreviouslystoredconfigur ationfile.Notethat
theImportfunctionwillonlyloadconfigurationinformationrelatedtomessagesandvariables.
ClicktheSystemtabatthetopofthepage.
ClicktheIMPORT/EXPORToptionfromthemenuonthelefthandsideofthe
page.
ClicktheChooseFilebutton,andthenselectthedesiredCSVfile,whichis
msg_con.csvinthiscase.
ClicktheImportbuttontoloadthecontentsoftheconfigurationfile,whichis
msg_con.csvintheillustrationabove.Oncethefilehasbeenloaded,themessage
“CSVfilesuccessfullyuploaded”willbedisplayed,asillustratedbelow.
n
o
p
q
n
o
q
p
iKANSeriesModbusLEDDisplayUserManualversion1.0.0Page20
Copyright©2016ICPDASCo.,Ltd.AllRightsReserved.Email:ser[email protected]om
3.4. COM port configuration
RS232andRS485arebothprovidedtocommunicatewithModbusRTUdevices.Bothinterfaces
usethesameconfigurationsettingsincludingBaudRate,DataBits,StopBit,andParity,butonly
oneinterfacecanbeusedatthesametime.TransmissiondataformatisN81,E81orO81
selectableontheiKANdevice.
ClicktheSystemtabatthetopofthepage.
ClicktheSERIALPORToptionfromthemenuonthelefthandside ofthepage.
EntertheBaudRate,DataBitts,StopBit(s)andParity;allthesettingsneedbe
identicalwiththeparametersusedontheModbusRTUdevice(s)for
transferringdatacorrectly.
ClicktheUpdateSettingsbuttontosavethenewvaluesandcompletethe
configurationprocess
n
o
q
p
n
o
p
q
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

ICP iKAN-124 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI